Comparison of angular and combined automatic tube current modulation techniques with constant tube current CT of the abdomen and pelvis

被引:160
作者
Rizzo, S
Kalra, M
Schmidt, B
Dalal, T
Suess, C
Flohr, T
Blake, M
Saini, S
机构
[1] Emory Univ Hosp, Dept Radiol, Atlanta, GA 30322 USA
[2] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[3] Siemens Med Solut, Forchheim, Germany
关键词
abdomen; CT technique; pelvis; radiation dose; tube current modulation;
D O I
10.2214/AJR.04.1513
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to compare image quality and radiation dose associated with abdominopelvic CT using combined modulation, angular modulation, and constant tube current. CONCLUSION. Compared with using a constant tube current to scan the abdomen and pelvis, the use of a combined modulation technique results in a substantial reduction (42-44%) in radiation dose with acceptable image noise and diagnostic acceptability.
引用
收藏
页码:673 / 679
页数:7
相关论文
共 11 条
  • [1] *EUR, 16262 EUR
  • [2] Dose reduction in subsecond multislice spiral CT examination of children by online tube current modulation
    Greess, H
    Lutze, J
    Nömayr, A
    Wolf, H
    Hothorn, T
    Kalender, WA
    Bautz, W
    [J]. EUROPEAN RADIOLOGY, 2004, 14 (06) : 995 - 999
  • [3] Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions
    Greess, H
    Wolf, H
    Baum, U
    Lell, M
    Pirkl, M
    Kalender, W
    Bautz, WA
    [J]. EUROPEAN RADIOLOGY, 2000, 10 (02) : 391 - 394
  • [4] Greess H, 1999, ROFO-FORTSCHR RONTG, V170, P246
  • [5] Helical CT of the body: A survey of techniques used for pediatric patients
    Hollingsworth, C
    Frush, DP
    Cross, M
    Lucaya, J
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (02) : 401 - 406
  • [6] Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadavers
    Kalender, WA
    Wolf, H
    Suess, C
    Gies, M
    Greess, H
    Bautz, WA
    [J]. EUROPEAN RADIOLOGY, 1999, 9 (02) : 323 - 328
  • [7] Techniques and applications of automatic tube current modulation for CT
    Kalra, MK
    Maher, MM
    Toth, TL
    Schmidt, B
    Westerman, BL
    Morgan, HT
    Saini, S
    [J]. RADIOLOGY, 2004, 233 (03) : 649 - 657
  • [8] Sixteen-detector row CT of abdomen and pelvis: Study for optimization of Z-axis modulation technique performed in 153 patients
    Kalra, MK
    Maher, MM
    Kamath, RS
    Horiuchi, T
    Toth, TL
    Halpern, EF
    Saini, S
    [J]. RADIOLOGY, 2004, 233 (01) : 241 - 249
  • [9] Comparison of z-axis automatic tube current modulation technique with fixed tube current CT scanning of abdomen and pelvis
    Kalra, MK
    Maher, MM
    Toth, TL
    Kamath, RS
    Halpern, EF
    Saini, S
    [J]. RADIOLOGY, 2004, 232 (02) : 347 - 353
  • [10] Strategies for CT radiation dose optimization
    Kalra, MK
    Maher, MM
    Toth, TL
    Hamberg, LM
    Blake, MA
    Shephard, JA
    Saini, S
    [J]. RADIOLOGY, 2004, 230 (03) : 619 - 628