Two-dimensional multi-criterion segmentation of pulmonary nodules on helical CT images

被引:72
|
作者
Zhao, BS [1 ]
Yankelevitz, D
Reeves, A
Henschke, C
机构
[1] Cornell Univ, Med Ctr, New York Hosp, Dept Radiol, New York, NY 10021 USA
[2] Cornell Univ, Sch Elect Engn, Ithaca, NY 14853 USA
关键词
image segmentation; multiple thresholding; gradient strength; shape analysis; computer-aided diagnosis; helical computed tomography; small pulmonary nodule;
D O I
10.1118/1.598605
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A multi-criterion algorithm for automatic delineation of small pulmonary nodules on helical CT images has been developed. In a slice-by-slice manner, the algorithm uses density, gradient strength, and a shape constraint of the nodule to automatically control segmentation process. The multiple criteria applied to separation of the nodule from its surrounding structures in lung are based on the fact that typical small pulmonary nodules on CT images have high densities, show a distinct difference in density at the boundary, and tend to be compact in shape. Prior to the segmentation, a region-of-interest containing the nodule is manually selected on the CT images. Then the segmentation process begins with a high density threshold that is decreased stepwise, resulting in expansion of the area of nodule candidates. This progressive region growing approach is terminated when subsequent thresholds provide either a diminished gradient strength of the nodule contour or significant changes of nodule shape :from the compact form. The shape criterion added to the algorithm can effectively prevent the high density surrounding structures (e.g., blood vessels) from being falsely segmented as nodule, which occurs frequently when only the gradient strength criterion is applied. This has been demonstrated by examples given in the Results section. The algorithm's accuracy has been compared with that of radiologist's manual segmentation, and no statistically significant difference has been found between the nodule areas delineated by radiologist and those obtained by the multi-criterion algorithm. The improved nodule boundary allows for more accurate assessment of nodule size and hence nodule growth over a short time period, and for better characterization of nodule edges. This information is useful in determining malignancy status of a nodule at an early stage and thus provides significant guidance for further clinical management. (C) 1999 American Association of Physicists in Medicine.
引用
收藏
页码:889 / 895
页数:7
相关论文
共 50 条
  • [1] Three-dimensional multicriterion automatic segmentation of pulmonary nodules of helical computed tomography images
    Zhao, BS
    Reeves, AP
    Yankelevitz, DF
    Henschke, CI
    OPTICAL ENGINEERING, 1999, 38 (08) : 1340 - 1347
  • [2] Detection of Pulmonary Nodules CT Images Combined with Two-Dimensional and Three-Dimensional Convolution Neural Networks
    Miao Guang
    Li Chaofeng
    LASER & OPTOELECTRONICS PROGRESS, 2018, 55 (05)
  • [3] Consistent segmentation of repeat CT scans for growth assessment in pulmonary nodules
    Zhao, BS
    Kostis, W
    Reeves, A
    Yankelevitz, D
    Henschke, C
    MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 : 1012 - 1018
  • [4] Segmentation of pulmonary nodules in three-dimensional CT images by use of a spiral-scanning technique
    Wang, Jiahui
    Engelmann, Roger
    Li, Qiang
    MEDICAL PHYSICS, 2007, 34 (12) : 4678 - 4689
  • [5] Automatic segmentation for pulmonary nodules in CT images based on multifractal analysis
    Lee, Cheng-Hsiung
    Jwo, Jung-Sing
    IET IMAGE PROCESSING, 2020, 14 (07) : 1347 - 1353
  • [6] Computer-aided diagnosis for pulmonary nodules based on helical CT images
    Kanazawa, K
    Kawata, Y
    Niki, N
    Satoh, H
    Ohmatsu, H
    Kakinuma, R
    Kaneko, M
    Moriyama, N
    Eguchi, K
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1998, 22 (02) : 157 - 167
  • [7] Contourlet Textual Features: Improving the Diagnosis of Solitary Pulmonary Nodules in Two Dimensional CT Images
    Wang, Jingjing
    Sun, Tao
    Gao, Ni
    Menon, Desmond Dev
    Luo, Yanxia
    Gao, Qi
    Li, Xia
    Wang, Wei
    Zhu, Huiping
    Lv, Pingxin
    Liang, Zhigang
    Tao, Lixin
    Liu, Xiangtong
    Guo, Xiuhua
    PLOS ONE, 2014, 9 (09):
  • [8] Automatic segmentation of pulmonary nodules on CT images by use of NCI lung image database consortium
    Tachibana, Rie
    Kido, Shoji
    MEDICAL IMAGING 2006: IMAGE PROCESSING, PTS 1-3, 2006, 6144
  • [9] Improved Two-Dimensional Fisher Criterion Image Segmentation Method and Its Applicatiion
    Liu, Yong
    Lin, Ying
    Yuan, Liang
    ADVANCED MATERIALS AND COMPUTER SCIENCE, PTS 1-3, 2011, 474-476 : 2302 - 2306
  • [10] Automated detection of pulmonary nodules in helical CT images based on an improved template-matching technique
    Lee, Y
    Hara, T
    Fujita, H
    Itoh, S
    Ishigaki, T
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (07) : 595 - 604