Development of a Computerized 4-D MRI Phantom for Liver Motion Study

被引:6
|
作者
Wang, Chunhao [1 ]
Yin, Fang-Fang [1 ,2 ]
Segars, W. P. [3 ]
Chang, Zheng [1 ]
Ren, Lei [1 ,2 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
[2] Duke Kunshan Univ, Med Phys Grad Program, Kunshan, Jiangsu, Peoples R China
[3] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
基金
美国国家卫生研究院;
关键词
MRI; computerized phantom; liver; organ motion; deformable registration; PHARMACOKINETIC ANALYSIS; ORGAN MOTION; XCAT; SIMULATION; THERAPY; HEAD;
D O I
10.1177/1533034617723753
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To develop a 4-dimensional computerized magnetic resonance imaging phantom with image textures extracted from real patient scans for liver motion studies. Methods: The proposed phantom was developed based on the current version of 4-dimensional extended cardiac-torso computerized phantom and a clinical magnetic resonance scan. Initially, the extended cardiac-torso phantom was voxelized in abdominal-chest region at the end of exhalation phase. Structures/tissues were classified into 4 categories: (1) Seven key textured organs, including liver, gallbladder, spleen, stomach, heart, kidneys, and pancreas, were mapped from a clinical T1-weighted liver magnetic resonance scan using deformable registration. (2) Large textured soft tissue volumes were simulated via an iterative pattern generation method using the same magnetic resonance scan. (3) Lung and intestine structures were generated by assigning uniform intensity with proper noise modeling. (4) Bony structures were generated by assigning the magnetic resonance values. A spherical hypointensity tumor was inserted into the liver. Other respiratory phases of the 4-dimensional phantom were generated using the backward deformation vector fields exported by the extended cardiac-torso program, except that bony structures were generated separately for each phase. A weighted image filtering process was utilized to improve the overall tissue smoothness at each phase. Results: Three 4-dimensional series with different motion amplitudes were generated. The developed motion phantom produced good illustrations of abdominal-chest region with anatomical structures in key organs and texture patterns in large soft tissue volumes. In a standard series, the tumor volume was measured as 13.90 0.11 cm(3) in a respiratory cycle and the tumor's maximum center-of-mass shift was 2.95 cm/1.84 cm on superior-inferior/anterior-posterior directions. The organ motion during the respiratory cycle was well rendered. The developed motion phantom has the flexibility of motion pattern variation, organ geometry variation, and tumor modeling variation. Conclusions: A 4-D computerized phantom was developed and could be used to produce image series with synthetic magnetic resonance textures for magnetic resonance imaging research of liver motion.
引用
收藏
页码:1051 / 1059
页数:9
相关论文
共 50 条
  • [41] Paired conditional generative adversarial network for highly accelerated liver 4D MRI
    Xu, Di
    Miao, Xin
    Liu, Hengjie
    Scholey, Jessica E.
    Yang, Wensha
    Feng, Mary
    Ohliger, Michael
    Lin, Hui
    Lao, Yi
    Yang, Yang
    Sheng, Ke
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (12):
  • [42] Comparative Evaluation of 4DCT and 3D T1/T2w MRI in Delineation of Moving Target: A Phantom Study
    Yang, Bin
    Tse, Mei Yan
    Wang, Jie Rong
    Yuan, Jing
    Hung, Shu Ting
    Chan, Wing Ki
    Wong, Yeung Sum
    Cheung, Kin Yin
    Yu, Siu Ki
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3889 - S3893
  • [43] 4-D Spatiotemporal Analysis of Ultrasound Contrast Agent Dispersion for Prostate Cancer Localization: A Feasibility Study
    Schalk, Stefan G.
    Demi, Libertario
    Smeenge, Martijn
    Mills, David M.
    Wallace, Kirk D.
    de la Rosette, Jean J. M. C. H.
    Wijkstra, Hessel
    Mischi, Massimo
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2015, 62 (05) : 839 - 851
  • [44] Development of a cost-effective 3D-printed MRI phantom for enhanced teaching of system performance and image quality concepts
    Yusuff, Habeeb
    Zorn, Pierre-Emmanuel
    Giraudeau, Celine
    Wach, Benoit
    Choquet, Philippe
    Chatelin, Simon
    Dillenseger, Jean-Philippe
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2024,
  • [45] Real-Time Motion Compensated Patient Positioning and Non-rigid Deformation Estimation Using 4-D Shape Priors
    Wasza, Jakob
    Bauer, Sebastian
    Hornegger, Joachim
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2012, PT II, 2012, 7511 : 576 - 583
  • [46] VALIDATION OF A NON-RIGID REGISTRATION METHOD FOR MOTION COMPENSATION IN 4D ULTRASOUND OF THE LIVER
    Vijayan, Sinara
    Klein, Stefan
    Hofstad, Erlend Fagertun
    Lindseth, Frank
    Ystgaard, Brynjulf
    Lango, Thomas
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 792 - 795
  • [47] Perfusion maps of the whole liver based on high temporal and spatial resolution contrast-enhanced MRI (4D THRIVE): Feasibility and initial results in focal liver lesions
    Coenegrachts, Kenneth
    Ghekiere, Johan
    Denolin, Vincent
    Gabriele, Beck
    Herigault, Gwen
    Haspeslagh, Marc
    Daled, Peter
    Bipat, Shandra
    Stoker, Jaap
    Rigauts, Hans
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 74 (03) : 529 - 535
  • [48] Evaluation of the toxic effect of the herbicide 2, 4-D on rat hepatocytes: an FT-IR spectroscopic study
    Dakhakhni, Tahani H.
    Raouf, Gehan A.
    Qusti, Safaa Y.
    EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 2016, 45 (04): : 311 - 320
  • [49] Multi-contrast four-dimensional magnetic resonance imaging (MC-4D-MRI): Development and initial evaluation in liver tumor patients
    Zhang, Lei
    Yin, Fang-Fang
    Li, Tian
    Teng, Xinzhi
    Xiao, Haonan
    Harris, Wendy
    Ren, Lei
    Kong, Feng-Ming Spring
    Ge, Hong
    Mao, Ronghu
    Cai, Jing
    MEDICAL PHYSICS, 2021, 48 (12) : 7984 - 7997
  • [50] Technical feasibility and clinical evaluation of 4D-MRI guided liver SBRT on the MR-linac
    van de Lindt, T. N.
    Nowee, M. E.
    Janssen, T.
    Schneider, C.
    Remeijer, P.
    van Pelt, V. W. J.
    Betgen, A.
    Jansen, E. P. M.
    Sonke, J. J.
    RADIOTHERAPY AND ONCOLOGY, 2022, 167 : 285 - 291