Development of a Computerized 4-D MRI Phantom for Liver Motion Study

被引:6
|
作者
Wang, Chunhao [1 ]
Yin, Fang-Fang [1 ,2 ]
Segars, W. P. [3 ]
Chang, Zheng [1 ]
Ren, Lei [1 ,2 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
[2] Duke Kunshan Univ, Med Phys Grad Program, Kunshan, Jiangsu, Peoples R China
[3] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
基金
美国国家卫生研究院;
关键词
MRI; computerized phantom; liver; organ motion; deformable registration; PHARMACOKINETIC ANALYSIS; ORGAN MOTION; XCAT; SIMULATION; THERAPY; HEAD;
D O I
10.1177/1533034617723753
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To develop a 4-dimensional computerized magnetic resonance imaging phantom with image textures extracted from real patient scans for liver motion studies. Methods: The proposed phantom was developed based on the current version of 4-dimensional extended cardiac-torso computerized phantom and a clinical magnetic resonance scan. Initially, the extended cardiac-torso phantom was voxelized in abdominal-chest region at the end of exhalation phase. Structures/tissues were classified into 4 categories: (1) Seven key textured organs, including liver, gallbladder, spleen, stomach, heart, kidneys, and pancreas, were mapped from a clinical T1-weighted liver magnetic resonance scan using deformable registration. (2) Large textured soft tissue volumes were simulated via an iterative pattern generation method using the same magnetic resonance scan. (3) Lung and intestine structures were generated by assigning uniform intensity with proper noise modeling. (4) Bony structures were generated by assigning the magnetic resonance values. A spherical hypointensity tumor was inserted into the liver. Other respiratory phases of the 4-dimensional phantom were generated using the backward deformation vector fields exported by the extended cardiac-torso program, except that bony structures were generated separately for each phase. A weighted image filtering process was utilized to improve the overall tissue smoothness at each phase. Results: Three 4-dimensional series with different motion amplitudes were generated. The developed motion phantom produced good illustrations of abdominal-chest region with anatomical structures in key organs and texture patterns in large soft tissue volumes. In a standard series, the tumor volume was measured as 13.90 0.11 cm(3) in a respiratory cycle and the tumor's maximum center-of-mass shift was 2.95 cm/1.84 cm on superior-inferior/anterior-posterior directions. The organ motion during the respiratory cycle was well rendered. The developed motion phantom has the flexibility of motion pattern variation, organ geometry variation, and tumor modeling variation. Conclusions: A 4-D computerized phantom was developed and could be used to produce image series with synthetic magnetic resonance textures for magnetic resonance imaging research of liver motion.
引用
收藏
页码:1051 / 1059
页数:9
相关论文
共 50 条
  • [31] Inter-Subject Variability of Respiratory Motion from 4D MRI
    Abd Rahni, Ashrani Aizzuddin
    Lewis, Emma
    Wells, Kevin
    2015 INTERNATIONAL CONFERENCE ON BIOSIGNAL ANALYSIS, PROCESSING AND SYSTEMS (ICBAPS), 2015,
  • [32] Continuously Deforming 4D Voxel Phantom for Realistic Representation of Respiratory Motion in Monte Carlo Dose Calculation
    Han, Min Cheol
    Seo, Jeong Min
    Lee, Se Hyung
    Kim, Chan Hyeong
    Yeom, Yeon Soo
    Thang Tat Nguyen
    Choi, Chansoo
    Kim, Seonghoon
    Jeong, Jong Hwi
    Sohn, Jason W.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (06) : 2918 - 2924
  • [33] Continuous real time 3D motion reproduction using dynamic MRI and precomputed 4DCT deformation fields
    Dasnoy-Sumell, Damien
    Souris, Kevin
    Van Ooteghem, G.
    Macq, Benoit
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (08): : 236 - 248
  • [34] A ROI-based global motion model established on 4DCT and 2D cine-MRI data for MRI-guidance in radiation therapy
    Garau, Noemi
    Via, Riccardo
    Meschin, Giorgia
    Lee, Danny
    Keall, Paul
    Riboldi, Marco
    Baroni, Guido
    Paganelli, Chiara
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (04):
  • [35] Development of a Dynamic 4D Anthropomorphic Breast Phantom for Contrast-based Breast Imaging
    Kiarashi, Nooshin
    Lin, Yuan
    Segars, Willliam P.
    Ghate, Sujata V.
    Ikejimba, Lynda
    Chen, Baiyu
    Lo, Joseph Y.
    Dobbins, James T., III
    Nolte, Loren W.
    Samei, Ehsan
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [36] The noise navigator: a surrogate for respiratory-correlated 4D-MRI for motion characterization in radiotherapy
    Navest, R. J. M.
    Mandija, S.
    Bruijnen, T.
    Stemkens, B.
    Tijssen, R. H. N.
    Andreychenko, A.
    Lagendijk, J. J. W.
    van den Berg, C. A. T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (01):
  • [37] Accuracy of respiratory motion measurement of 4D-MRI: A comparison between cine and sequential acquisition
    Liu, Yilin
    Yin, Fang-Fang
    Rhee, DongJoo
    Cai, Jing
    MEDICAL PHYSICS, 2016, 43 (01) : 179 - 187
  • [38] Computational and Phantom-Based Feasibility Study of 3D dcNCI With Ultra-Low-Field MRI
    Hofner, Nora
    Storm, Jan-Hendrik
    Hommen, Peter
    Cassara, Antonino Mario
    Korber, Rainer
    FRONTIERS IN PHYSICS, 2021, 9
  • [39] Automatic self-gated 4D-MRI construction from free-breathing 2D acquisitions applied on liver images
    Liset Vázquez Romaguera
    Nils Olofsson
    Rosalie Plantefève
    Elodie Lugez
    Jacques De Guise
    Samuel Kadoury
    International Journal of Computer Assisted Radiology and Surgery, 2019, 14 : 933 - 944
  • [40] Automatic self-gated 4D-MRI construction from free-breathing 2D acquisitions applied on liver images
    Romaguera, Liset Vazquez
    Olofsson, Nils
    Plantefeve, Rosalie
    Lugez, Elodie
    De Guise, Jacques
    Kadoury, Samuel
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2019, 14 (06) : 933 - 944