High Survival of Modular Tapered Stems for Proximal Femoral Bone Defects at 5 to 10 Years Followup

被引:104
作者
Van Houwelingen, Andrew P. [1 ]
Duncan, Clive P. [1 ]
Masri, Bassam A. [1 ]
Greidanus, Nelson V. [1 ]
Garbuz, Donald S. [1 ]
机构
[1] Univ British Columbia, Dept Orthopaed, Vancouver, BC V5Z 4E3, Canada
关键词
TOTAL HIP-ARTHROPLASTY; POROUS-COATED STEMS; REVISION STEM; FIXATION; REPLACEMENT; CLASSIFICATION; SATISFACTION; ALLOGRAFT; COMPONENT; FRACTURE;
D O I
10.1007/s11999-012-2552-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Currently, the two most commonly used options for the revision of femoral components in North America are: cylindrical, nonmodular, cobalt-chromium stems and tapered, fluted, modular, titanium (TFMT) stems. Previous reports have cited high failure rates with cylindrical cobalt chrome stems in large femoral defects but the longer term survival of the fluted stems is unknown. We examined the 5- to 10-year survival of TFMT stems implanted for severe femoral defects. We reviewed all 65 patients with severe proximal bone defects revised with the TMFT stem between January 2000 and 2006. Ten were lost to followup and seven were dead, leaving 48 patients for followup at 5 to 10 years (mean, 84 months; range, 60-120 months). All patients completed five quality-of-life (QOL) questionnaires. Radiographs were evaluated for loosening, subsidence, and preservation of proximal host bone stock. Implant survivorship was 90%. No patient underwent revision for either subsidence or loosening. Subsidence occurred in seven patients (average, 12.3 mm) but all achieved secondary stability. Five patients underwent revision as a result of fracture of the stem and all had the original standard stem design, which has since been modified. All five implant fractures occurred at the modular stem junction. Mean QOL outcomes were: WOMAC = 81 (pain), Oxford = 75, SF-12 = 54 (mental) and 38 (physical), UCLA Activity = 4, and satisfaction overall = 73. Midterm survivorship of modular titanium stems in large femoral defects is high; however, ongoing surveillance of stem junctional fatigue life is required. Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
引用
收藏
页码:454 / 462
页数:9
相关论文
共 38 条
  • [1] TREATMENT OF PRIMARY OSTEOARTHRITIS OF THE HIP - A COMPARISON OF TOTAL JOINT AND SURFACE REPLACEMENT ARTHROPLASTY
    AMSTUTZ, HC
    THOMAS, BJ
    JINNAH, R
    KIM, W
    GROGAN, T
    YALE, C
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (02) : 228 - 241
  • [2] BELLAMY N, 1988, J RHEUMATOL, V15, P1833
  • [3] Böhm P, 2001, J BONE JOINT SURG AM, V83A, P1023
  • [4] Fractures of distally-fixed femoral stems after revision arthroplasty
    Busch, CA
    Charles, MN
    Bourne, RB
    Rorabeck, CH
    MacDonald, SJ
    McCalden, RW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (10): : 1333 - 1336
  • [5] Questionnaire on the perceptions of patients about total hip replacement
    Dawson, J
    Fitzpatrick, R
    Carr, A
    Murray, D
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (02): : 185 - 190
  • [6] Della Valle CJ, 2003, J BONE JOINT SURG AM, V85A, P1
  • [7] ENGH CA, 1990, CLIN ORTHOP RELAT R, P107
  • [8] Extensively porous-coated femoral revision for severe femoral bone loss - Minimum 10-year follow-up
    Engh, CA
    Ellis, TJ
    Koralewicz, LM
    McAuley, JP
    Engh, CA
    [J]. JOURNAL OF ARTHROPLASTY, 2002, 17 (08) : 955 - 960
  • [9] Improved outcome in femoral revision arthroplasty with tapered fluted modular titanium stems
    Garbuz, Donald S.
    Toms, Andrew
    Masri, Bassam A.
    Duncan, Clive P.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (453) : 199 - 202
  • [10] Stress-shielding of the proximal femur using an extensively porous-coated femoral component without allograft in revision surgery A 5-TO 17-YEAR FOLLOW-UP STUDY
    Garcia-Cimbrelo, E.
    Garcia-Rey, E.
    Cruz-Pardos, A.
    Madero, R.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (10): : 1363 - 1369