Comparison of cutout resistance of dynamic condylar screw and proximal femoral nail in reverse oblique trochanteric fractures: A biomechanical study

被引:7
|
作者
Cheema, Gursimrat Singh [1 ]
Rastogi, Amit [2 ]
Singh, Vakil [3 ]
Goel, Satish Chandra [2 ]
Mishra, Diwakar [1 ]
Arora, Sumit [1 ]
机构
[1] Maulana Azad Med Coll & Associated Lok Nayak Hosp, Dept Orthopaed Surg, New Delhi, India
[2] Banaras Hindu Univ, Inst Med Sci, Dept Orthopaed, Varanasi 221005, Uttar Pradesh, India
[3] Banaras Hindu Univ, Inst Technol, Varanasi 221005, Uttar Pradesh, India
关键词
Dynamic condylar screw; proximal femoral nailing; reverse oblique trochanteric fractures; INTERTROCHANTERIC HIP-FRACTURES; GAMMA-NAIL; FIXATION; FEMUR; DHS; INTRAMEDULLARY; PLATE;
D O I
10.4103/0019-5413.96369
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Reverse oblique trochanteric fracture of femur is a distinct fracture pattern. 95 Dynamic condylar screw (DCS) and proximal femoral nail (PFN) are currently the most commonly used implants for its fixation. This study aims to biomechanically compare the cutout resistance as well as modes of failure of DCS and PFN in reverse oblique trochanteric fractures. Materials and Methods: Sixteen freshly harvested cadaveric proximal femoral specimens were randomly assigned to three mean bone mineral density matched groups, eight of which were implanted with 95 DCS and the other eight with PFN. The constructs were made unstable to resemble a reverse oblique trochanteric fracture by removing a standard size posteromedial wedge. These constructs were subjected to computer controlled cyclic compressive loading with 200 kg at a frequency of 1 cycle/second (1 Hz) and end points of both the groups were analyzed. Results: The bending moment of the PFN group was approximately 50% less than that of the DCS group (P<0.0001). The PFN group resisted more number of cycles than the DCS group (P=0.03) and showed lesser number of component failures as compared with the DCS group (P=0.003). Conclusions: The PFN is biomechanically superior to DCS for the fixation of reverse oblique trochanteric fractures of femur.
引用
收藏
页码:259 / 265
页数:7
相关论文
共 50 条
  • [31] Biomechanical comparison of screw vs. cerclage refixation in orthogeriatric lesser trochanteric fractures: a cadaveric study
    Linhart, Christoph
    Kistler, Manuel
    Woiczinski, Matthias
    Neudeck, Rouven
    Kassube, Matthias
    Boecker, Wolfgang
    Ehrnthaller, Christian
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2023, 49 (01) : 181 - 188
  • [32] A STUDY ON COMPARISON OF RESULTS OF PROXIMAL FEMORAL NAIL AND DHS IN UNSTABLE PROXIMAL FEMORAL FRACTURES
    Bajpai, Himanshu
    Singh, Sanjeev Kumar
    Gupta, Pankaj
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2019, 8 (07): : 441 - 446
  • [33] Biomechanical comparison of dynamic condylar screw and locking compression plate fixation in unstable distal femoral fractures: An in vitro study
    Ashutosh Kumar Singh
    Amit Rastogi
    Vakil Singh
    Indian Journal of Orthopaedics, 2013, 47 : 615 - 620
  • [34] Sliding hip screw versus IM nail in reverse oblique trochanteric and subtrochanteric fractures. A study of 2716 patients in the Norwegian Hip Fracture Register
    Matre, Kjell
    Havelin, Leif Ivar
    Gjertsen, Jan-Erik
    Vinje, Tarjei
    Espehaug, Birgitte
    Fevang, Jonas Meling
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (06): : 735 - 742
  • [35] Is proximal femoral nail antirotation superior to gamma nail and dynamic hip screw in treatment of intertrochanteric fractures? a pairwise and network meta-analysis
    Yin, Si
    Dai, Xing
    Zhang, Dangfeng
    Du, Heng
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (12): : 22993 - 23007
  • [36] Comparison of unstable inter-trochanteric femur fracture treated with Dynamic Hip Screw and Proximal Femur Nail
    Saleem, Muhammad
    Ahmed, Masroor
    Kumar, Mukesh
    Sahar, Khurram
    Hussain, Ghulam
    Bux, Muhammad
    RAWAL MEDICAL JOURNAL, 2020, 45 (03): : 648 - 651
  • [37] Biomechanical stability of short versus long proximal femoral nails in osteoporotic subtrochanteric A3 reverse-oblique femoral fractures: a cadaveric study
    Linhart, Christoph
    Kistler, Manuel
    Kussmaul, Adrian C.
    Woiczinski, Matthias
    Boecker, Wolfgang
    Ehrnthaller, Christian
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (01) : 389 - 397
  • [38] Risk factors for implant failure in reverse oblique and transverse intertrochanteric fractures treated with proximal femoral nail antirotation (PFNA)
    Hao, Youliang
    Zhang, Zhishan
    Zhou, Fang
    Ji, Hongquan
    Tian, Yun
    Guo, Yan
    Lv, Yang
    Yang, Zhongwei
    Hou, Guojin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14 (01)
  • [39] SURGICAL MANAGEMENT OF INTERTROCHANTERIC FRACTURES: A STUDY USING DYNAMIC HIP SCREW AND PROXIMAL FEMORAL NAIL
    Rao, D. Venkateswara
    Kumar, Chinta Shyam
    Sangepu, Anvesh
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (66): : 11440 - 11445
  • [40] Comparison of Dynamic Hip Screw and Proximal Femoral Nailing Techniques in Stable Intertrochanteric Fractures
    Shiraz, Salman
    Shujauddin, Mohammad
    Hasan, Khalid
    Elramadi, Ahmed
    Ahmed, Ghalib
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (01)