Characterization of industrial alkylpolyphosphonates by infusion electrospray ionization-ion trap mass spectrometry with identification of the impurities by tandem capillary zone electrophoresis

被引:8
作者
Ortega-Gadea, S
Bernabé-Zafón, V
Simó-Alfonso, EF
Ochs, CJ
Ramis-Ramos, G
机构
[1] Univ Valencia, Fac Quim, Dept Quim Analit, E-46100 Burjassot, Spain
[2] Quim Oro SA, St Antoni Benaixeve, Spain
来源
JOURNAL OF MASS SPECTROMETRY | 2006年 / 41卷 / 01期
关键词
alkylaminopolyphosphonates; bisphosphonates; hydroxyphosphonates; phosphonopolycarboxylates; ion trap mass spectrometry; electrospray ionization; capillary zone electrophoresis;
D O I
10.1002/jms.940
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Technical grade diethylene-triaminepentakis(methylenephosphonic acid) (I), dihexamethylene-triaminepentakis(methylenephosphonic acid) (II), ethylene-diaminetetrakis(methylenephosphonic acid) (III), hexamethylene-diaminetetrakis(methylenephosphonic acid) (IV), amino-tris(methylenephosphonic acid) (V), hydroxyethyl-aminobis(methylenephosphonic acid) (VI), 1-hydroxyethylidene-1,1-diphosphonic acid (VII), and 2-phosphonobutane-1,2,4-tricarboxylic acid (VIII) were characterized by ion trap mass spectrometry with electrospray ionization (ESI-ITMS). Using the negative ion mode and acid and alkaline media, peak series corresponding to the nominal compounds and to impurities with a lower number of phosphonate groups were distinguished in I-V. Each series was constituted by [M - nH + (n - 1)Na](-) peaks and peaks produced from them by losses of water, H3PO3(or water plus HPO2), and combined losses. For each [M - nH + (n - 1)Na](-) peak, the number of losses coincided with the number of phosphonate groups not bound to sodium ions minus one (the group bearing the charge). Owing to the hydroxyethyl group, the spectrum of VI was dominated by the formation of intermolecular esters, with both losses and gains of water according to [nM - H mH(2)O](-)(_). A series of [M - nH + (n - 1)Na](-) peaks were observed for VII and VIII, showing in the latter case that the carboxylate groups may also form adducts with sodium ions. Losses of water and H(3)PO(3)were observed in VII, whereas losses of water, CO2, and HPO3 were seen in VIII. The reaction pathways leading to the production of the observed ions are described. The nominal compounds and the impurities were also separated and identified by capillary electrophoresis with ESI-ITMS detection. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:23 / 33
页数:11
相关论文
共 26 条
[1]  
[Anonymous], PHOSPHORUS ENV TECHN
[2]   Conventional analytical methods for chemical warfare agents [J].
Hill, HH ;
Martin, SJ .
PURE AND APPLIED CHEMISTRY, 2002, 74 (12) :2281-2291
[3]   Application of microcolumn liquid chromatography and capillary electrophoresis with flame photometric detection for the screening of degradation products of chemical warfare agents in water and soil [J].
Hooijschuur, EWJ ;
Kientz, CE ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2001, 928 (02) :187-199
[4]   Determination of alkylphosphonic acids by microcolumn liquid chromatography with gradient elution coupled on-line with flame photometric detection [J].
Hooijschuur, EWJ ;
Kientz, CE ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2001, 907 (1-2) :165-172
[5]   Development and validation of a capillary zone electrophoretic method for the determination of bisphosphonate and phosphonate impurities in clodronate [J].
Huikko, K ;
Kostiainen, R .
JOURNAL OF CHROMATOGRAPHY A, 2000, 893 (02) :411-420
[6]   Analysis of bisphosphonates by capillary electrophoresis-electrospray ionization mass spectrometry [J].
Huikko, K ;
Kostiainen, R .
JOURNAL OF CHROMATOGRAPHY A, 2000, 872 (1-2) :289-298
[7]   Electrospray ionization mass spectrometry and tandem mass spectrometry of clodronate and related bisphosphonate and phosphonate compounds [J].
Huikko, K ;
Kotiaho, T ;
Yli-Kauhaluoma, J ;
Kostiainen, R .
JOURNAL OF MASS SPECTROMETRY, 2002, 37 (02) :197-208
[8]   Determination of alkylphosphonic acids using micellar electrokinetic chromatography with laser-induced fluorescence detection and high-salt stacking [J].
Jiang, J ;
Lucy, CA .
JOURNAL OF CHROMATOGRAPHY A, 2002, 966 (1-2) :239-244
[9]   Determination of organic phosphonates in aqueous samples using liquid chromatography particle-beam mass spectrometry [J].
Klinger, J ;
Sacher, F ;
Brauch, HJ ;
Maier, D .
ACTA HYDROCHIMICA ET HYDROBIOLOGICA, 1997, 25 (02) :79-86
[10]  
MAHABIR K, 1997, J CHROMATOGR A, V771, P1155