Short-term results of hip revisions with a curved cementless modular stem in association with the surgical approach

被引:23
作者
Fink, Bernd [1 ]
Grossmann, Alexandra [1 ]
Schubring, Svenja [2 ]
Schulz, Martin S. [1 ]
Fuerst, Martin [2 ]
机构
[1] Orthopaed Clin Markgroningen gGmbH, Clin Joint Replacement Gen & Rheumat Orthopaed, D-71706 Markgroningen, Germany
[2] Rheumaklin Bad Bramstedt, Dept Orthopaed, D-24576 Bad Bramstedt, Germany
关键词
Hip revision; Modular cementless stem; Transfemoral; Approach; EXTENDED TROCHANTERIC OSTEOTOMY; POROUS-COATED STEMS; FEMORAL REVISION; FOLLOW-UP; ARTHROPLASTY; PROSTHESIS; REPLACEMENT; FIXATION; JOINT;
D O I
10.1007/s00402-008-0617-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A prospective study was designed to test the hypothesis that short-term results after hip revisions are in association with the surgical approach with lower clinical scores for the transfemoral approach. A total of 120 hip revision operations with the modular cementless revision stem "Revitan Curved" (Zimmer GmbH, Winterthur, Switzerland), of which 42 replacements involved an endofemoral (posterolateral) approach and 78 implantations a transfemoral approach, were followed up over a period of at least 24 months. In the early post-operative stage, stems implanted transfemoral were associated with significantly lower Harris Hip Scores and a significantly more frequent appearance of Trendelenburg signs. The differences lessened at the end of the follow-up period. Within the group of transfemoral implantation, all six stems with a circular fixation zone measuring less than 3 cm had subsided and two of these had become loose; none of the stems with greater fixation zones exhibited these properties. In the case of the endofemoral implants, three stems exhibited sinking but there did not appear to be any relationship between this event and length of fixation zone. The surgical approach has an association with the short-time outcomes of hip revsions using cementless modular stems. Transfemoral implantation of the "Revitan curved" stem requires a fixation zone of at least 3 cm and a longer period of rehabilitation.
引用
收藏
页码:65 / 73
页数:9
相关论文
共 40 条
  • [1] BIRCHER HP, 2001, TECHNIK RESULTATE OR, V30, P294
  • [2] Böhm P, 2001, J BONE JOINT SURG AM, V83A, P1023
  • [3] Böhm P, 2004, CLIN ORTHOP RELAT R, P148
  • [4] The uncemented diaphysal fixation of femoral revision stems in case of large bone defects -: Analysis of twelve years experience with the Wagner SL revision stem
    Böhm, P
    Bischel, O
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2001, 139 (03): : 229 - 239
  • [5] CHALLGAHAN JJ, 1985, J BONE JOINT SURG AM, V67, P1074
  • [6] Extended slide trochanteric osteotomy for revision total hip arthroplasty
    Chen, WM
    McAuley, JP
    Engh, CA
    Hopper, RH
    Engh, CA
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (09) : 1215 - 1219
  • [7] Della Valle CJ, 2003, J BONE JOINT SURG AM, V85A, P2385
  • [8] DOHMAE Y, 1988, CLIN ORTHOP RELAT R, P214
  • [9] DUNCAN DP, 1995, INSTR COURSE LECT, V44, P293
  • [10] Fink B, 2005, UNFALLCHIRURG, V108, P1029, DOI 10.1007/s00113-005-0990-4