A new echographic cryoprobe for in vivo ultrasonic monitoring of skin cryosurgery

被引:0
|
作者
Laugier, P [1 ]
Lefaix, JL [1 ]
Berger, G [1 ]
机构
[1] CNRS, Lab Imagerie Parametr, UMR 7623, F-75006 Paris, France
来源
1998 IEEE ULTRASONICS SYMPOSIUM - PROCEEDINGS, VOLS 1 AND 2 | 1998年
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
One of the main difficulties encountered in cryosurgery is the uncertainty in the extent and depth of the tissue effectively treated during the freezing process. Our objective was to evaluate ultrasonic control of skin cryosurgery using a new echographic cryoprobe in vivo. The echographic cryoprobe, developed specifically for dermatology applications, combines a high-frequency (20 MHz) miniature ultrasonic transducer and a N2O-driven closed-cryoprobe. The operation of the echographic cryoprobe was assessed, under in vivo conditions similar to those used in human therapeutics, on normal skin of 3 females "Large-White" pigs under anesthesia. The edge of the growing ice layer was successfully and reproducibly detected and located during the freezing process. The average rate of growth (10(-2) mm/s) of the iceball was found to be 12.2+/-1.0 (pig N-o 1), 9.0+/-1.0 (pig N-o 2), 8.4+/-0.9 (pig N-o 3). The echographic cryoprobe had a built-in high-frequency ultrasonic transducer that served two functions. It enabled in vivo real-time monitoring of depth penetration of the iceball: and gives important feedback to the operator or to the console relating to the sate of growth of the iceball. Automatic (i.e., operator-independent) detection of the echo signal from the freezing front and calculation of the depth penetration of the iceball was possible.
引用
收藏
页码:1337 / 1340
页数:4
相关论文
共 50 条
  • [41] In vivo monitoring rat skin wound healing using nonlinearoptical microscopy
    Chen, Jing
    Guo, Chungen
    Zhang, Fan
    Xu, Yahao
    Zhu, Xiaoqin
    Xiong, Shuyuan
    Chen, Jianxin
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS VI, 2014, 9268
  • [42] In vivo monitoring for internal contamination:: New techniques for new needs
    Franck, D
    Genicot, JL
    Pihet, P
    Schnuer, K
    Spitz, H
    RADIATION PROTECTION DOSIMETRY, 2000, 89 (3-4) : 159 - 161
  • [43] Statistics of envelope of high-frequency ultrasonic backscatter from human skin in vivo
    Raju, BI
    Srinivasan, MA
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (07) : 871 - 882
  • [44] In vivo monitoring for internal contamination: New techniques for new needs
    Smart, R.S.
    Physicist, 2001, 38 (03):
  • [45] Comparison of global and local estimations of ultrasonic parameters at 20 MHz:: In vivo normal skin
    Fournier, C
    Bridal, SL
    Laugier, P
    Berger, G
    2000 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2000, : 1367 - 1370
  • [46] A New Ex Vivo Human Skin Burn Model
    Labouchere, Ania
    Haselbach, Daniel
    Michetti, Murielle
    Pythoud, Catherine
    Raffoul, Wassim
    Applegate, Lee Ann
    Hirt-Burri, Nathalie
    de Buys Roessingh, Anthony
    JOURNAL OF BURN CARE & RESEARCH, 2024, 45 (02): : 308 - 317
  • [47] A new method for determining the emissivity of the human skin in vivo
    Sanchez-Marin, Francisco J.
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [48] SkinChip®, a new tool for investigating the skin surface in vivo
    Lévêque, JL
    Querleux, B
    SKIN RESEARCH AND TECHNOLOGY, 2003, 9 (04) : 343 - 347
  • [49] Monitoring skin microvascular dysfunction of type 1 diabetic mice using in vivo skin optical clearing
    Feng, Wei
    Shi, Rui
    Zhu, Dan
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS XV, 2018, 10493
  • [50] Ultrasonic monitoring of setting and hardening of cement mortar—A new device
    H. W. Reinhardt
    C. U. Große
    A. T. Herb
    Materials and Structures, 2000, 33 : 581 - 583