Load Effect Analysis and Maximum Power Transfer Tracking of CPT System

被引:21
作者
Mostafa, Tarek M. [1 ]
Bui, Dai [2 ]
Muharam, Aam [3 ]
Hu, Aiguo Patrick [2 ]
Hattori, Reiji [3 ]
机构
[1] King Abdullah Univ Sci & Technol, CEMSE Div, Thuwal 23955, Saudi Arabia
[2] Univ Auckland, Dept Elect & Comp Engn, Auckland 1010, New Zealand
[3] Kyushu Univ, ASEM, Interdisciplinary Grad Sch Engn Sci, Fukuoka 8168580, Japan
关键词
Wireless power transfer (WPT); capacitive power transfer (CPT); maximum power tracking; impedance matching; optimal load tracking; EFFICIENCY POINT TRACKING; CAPACITIVE POWER; WIRELESS; MATRIX;
D O I
10.1109/TCSI.2020.2981195
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Owing to the flexibility of coupling structure, low standing losses and low Electromagnetic Interference (EMI), capacitive power transfer (CPT) has drawn much attention as one of the new wireless power transfer (WPT) technologies. However, to date, the load effect on the system performance has not been analyzed comprehensively, and the CPT system is usually fully tuned (tank network resonant frequency fully tuned to the fundamental components of the nominal switching frequency), which is challenging to maintain practically. Based on these considerations, this paper first provides a detailed analysis of how the load can affect the performance of a CPT system. An optimal load resistance is shown to exist for a CPT system with a non-fully/partially tuned LCC tank (tank network resonant frequency is designed to be lower than the fundamental components of the switching frequency). By dynamically transforming the load to its optimal value, the system can transfer maximum power to the load while maintaining zero voltage switching (ZVS) operation. Then, a controlled buck-boost converter based on perturbation and observation algorithm is introduced to the system to obtain the optimal equivalent resistance against the actual load variations via tracking the maximum power transfer point. The final prototype has demonstrated that a maximum power of 10 W is obtained, with an end-to-end power efficiency of about 70% over a wide range of load variations from 5 Omega to 1 k Omega.
引用
收藏
页码:2836 / 2848
页数:13
相关论文
共 35 条
[1]   Wireless Power Transfer With Automatic Feedback Control of Load Resistance Transformation [J].
Ahn, Dukju ;
Kim, Seongmin ;
Moon, Jungick ;
Cho, In-Kui .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (11) :7876-7886
[2]  
[Anonymous], 1999, IEEE STANDARD SAFETY, P1, DOI DOI 10.1109/IEEESTD.1999.89423
[3]   Automated Impedance Matching System for Robust Wireless Power Transfer via Magnetic Resonance Coupling [J].
Beh, Teck Chuan ;
Kato, Masaki ;
Imura, Takehiro ;
Oh, Sehoon ;
Hori, Yoichi .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (09) :3689-3698
[4]  
Bui D., 2018, PROC IEEE PELS WORKS, P1
[5]   Capacitive inter-chip data and power transfer for 3-D VLSI [J].
Culurciello, Eugenio ;
Andreou, Andreas G. .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2006, 53 (12) :1348-1352
[6]   Maximum Efficiency Tracking for Wireless Power Transfer Systems With Dynamic Coupling Coefficient Estimation [J].
Dai, Xin ;
Li, Xiaofei ;
Li, Yanling ;
Hu, Aiguo Patrick .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (06) :5005-5015
[7]  
Erickson R.W., 2004, FUNDAMENTALS POWER E, V2nd ed.
[8]   Resonant Electrical Coupling: Circuit Model and First Experimental Results [J].
Fernandes, Ricardo Dias ;
Matos, Joao Nuno ;
Carvalho, Nuno Borges .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2015, 63 (09) :2983-2990
[9]   Loading and Power Control for a High-Efficiency Class E PA-Driven Megahertz WPT System [J].
Fu, Minfan ;
Yin, He ;
Liu, Ming ;
Ma, Chengbin .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (11) :6867-6876
[10]   Analysis and Tracking of Optimal Load in Wireless Power Transfer Systems [J].
Fu, Minfan ;
Yin, He ;
Zhu, Xinen ;
Ma, Chengbin .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (07) :3952-3963