The use of a 3-dimensional computed tomography bone database to evaluate the risk of distal contact between the rasp tip and the endosteal cortical bone

被引:2
作者
Connor, Emmalynn [1 ]
Cowie, Jonathan G. [2 ]
Wuestemann, Thies [1 ]
Howell, Jonathan R. [3 ]
Whitehouse, Sarah L. [2 ]
Crawford, Ross W. [2 ]
机构
[1] Stryker Orthopaed, Mahwah, NJ USA
[2] Queensland Univ Technol, Prince Charles Hosp, Inst Hlth & Biomed Innovat, Brisbane, Qld, Australia
[3] Royal Devon & Exeter NHS Fdn Trust, Princess Elizabeth Orthopaed Ctr, Exeter, Devon, England
关键词
arthroplasty; replacement; hip; femur; CEMENTED FEMORAL COMPONENT; 1ST; 325; HIPS; FOLLOW-UP; EXETER; ARTHROPLASTY; STEM;
D O I
10.1177/1602400308
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose. To use a 3-dimensional computed tomography (CT) bone database to evaluate the risk of distal contact between the rasp tip and the endosteal cortical bone. Methods. Using a 3-dimensional CT bone database, the rasps for Exeter stems of 125 mm in length and body size 1, with a femoral offset of 37.5, 44, or 50 mm were compared with those for Exeter stems of 150 mm in length and same body size with the corresponding femoral offset. Rasp geometry was determined using an engineering drawing software. Results. Of the 631 femurs in the database, 238 (187 Caucasian and 51 Asian) were of appropriate femoral offset and proximal body size to receive a stem with an offset of 37.5, 44, or 50 mm. Of these, 145 (115 Caucasian and 30 Asian) femurs were of champagne flute type; the prevalence was comparable between the 2 populations (61% vs. 59%, p=0.729). When using the 150-mm rasp, 70 (55 Caucasian and 15 Asian) of the 238 femurs had distal contact between the rasp and femoral cortex; the prevalence was comparable between the 2 populations (29% vs. 29%, relative risk=1.0, p=1.0). Distal contact between the rasp and femoral cortex occurred more commonly in champagne-flute-type femurs than other femurs in the anteroposterior plane (28% [41/145] vs. 2% [2/93], relative risk=13.1, p<0.001) and in the mediolateral plane (27% [39/145] vs. 14% [13/ 93], relative risk=1.92, p=0.019). When using the 125-mm rasp, only one femur (with a canal flare index of 4.52) had distal contact in the mediolateral plane with an offset of 37.5 mm. Distal contact between the rasp and femoral cortex occurred more often with the 150-mm rasp than the 125-mm rasp in both planes (p<0.001). Conclusion. The use of a shorter stem may enhance anatomic fit in patients with a narrow femoral canal and prevent distal contact between the rasp and femoral cortex.
引用
收藏
页码:312 / 316
页数:5
相关论文
共 15 条
  • [11] NOBLE PC, 1988, CLIN ORTHOP RELAT R, P148
  • [12] Sivananthan S, 2003, J Orthop Surg (Hong Kong), V11, P148
  • [13] First Series of Exeter Small Stem Primary Total Hip Arthroplasty Minimum 5 Years of Follow-Up
    Tai, Cheh Chin
    Nam, Hui Yin
    Abbas, Azlina Amir
    Merican, Azhar M.
    Choon, Siew Kit
    [J]. JOURNAL OF ARTHROPLASTY, 2009, 24 (08) : 1200 - 1204
  • [14] The Exeter universal cemented femoral component at 8 to 12 years - A study of the first 325 hips
    Williams, HDW
    Browne, G
    Gie, GA
    Ling, RSM
    Timperley, AJ
    Wendover, NA
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (03): : 324 - 334
  • [15] The use of the cemented Exeter Universal femoral stem in a District General Hospital A MINIMUM TEN-YEAR FOLLOW-UP
    Young, L.
    Duckett, S.
    Dunn, A.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (02): : 170 - 175