The use of a 3-dimensional computed tomography bone database to evaluate the risk of distal contact between the rasp tip and the endosteal cortical bone

被引:2
作者
Connor, Emmalynn [1 ]
Cowie, Jonathan G. [2 ]
Wuestemann, Thies [1 ]
Howell, Jonathan R. [3 ]
Whitehouse, Sarah L. [2 ]
Crawford, Ross W. [2 ]
机构
[1] Stryker Orthopaed, Mahwah, NJ USA
[2] Queensland Univ Technol, Prince Charles Hosp, Inst Hlth & Biomed Innovat, Brisbane, Qld, Australia
[3] Royal Devon & Exeter NHS Fdn Trust, Princess Elizabeth Orthopaed Ctr, Exeter, Devon, England
关键词
arthroplasty; replacement; hip; femur; CEMENTED FEMORAL COMPONENT; 1ST; 325; HIPS; FOLLOW-UP; EXETER; ARTHROPLASTY; STEM;
D O I
10.1177/1602400308
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose. To use a 3-dimensional computed tomography (CT) bone database to evaluate the risk of distal contact between the rasp tip and the endosteal cortical bone. Methods. Using a 3-dimensional CT bone database, the rasps for Exeter stems of 125 mm in length and body size 1, with a femoral offset of 37.5, 44, or 50 mm were compared with those for Exeter stems of 150 mm in length and same body size with the corresponding femoral offset. Rasp geometry was determined using an engineering drawing software. Results. Of the 631 femurs in the database, 238 (187 Caucasian and 51 Asian) were of appropriate femoral offset and proximal body size to receive a stem with an offset of 37.5, 44, or 50 mm. Of these, 145 (115 Caucasian and 30 Asian) femurs were of champagne flute type; the prevalence was comparable between the 2 populations (61% vs. 59%, p=0.729). When using the 150-mm rasp, 70 (55 Caucasian and 15 Asian) of the 238 femurs had distal contact between the rasp and femoral cortex; the prevalence was comparable between the 2 populations (29% vs. 29%, relative risk=1.0, p=1.0). Distal contact between the rasp and femoral cortex occurred more commonly in champagne-flute-type femurs than other femurs in the anteroposterior plane (28% [41/145] vs. 2% [2/93], relative risk=13.1, p<0.001) and in the mediolateral plane (27% [39/145] vs. 14% [13/ 93], relative risk=1.92, p=0.019). When using the 125-mm rasp, only one femur (with a canal flare index of 4.52) had distal contact in the mediolateral plane with an offset of 37.5 mm. Distal contact between the rasp and femoral cortex occurred more often with the 150-mm rasp than the 125-mm rasp in both planes (p<0.001). Conclusion. The use of a shorter stem may enhance anatomic fit in patients with a narrow femoral canal and prevent distal contact between the rasp and femoral cortex.
引用
收藏
页码:312 / 316
页数:5
相关论文
共 15 条
  • [1] Banerjee Samik, 2014, Surg Technol Int, V24, P288
  • [2] The Exeter Universal cemented femoral component at 15 to 17 years AN UPDATE ON THE FIRST 325 HIPS
    Carrington, N. C.
    Sierra, R. J.
    Gie, G. A.
    Hubble, M. J. W.
    Timperley, A. J.
    Howell, J. R.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (06): : 730 - 737
  • [3] Primary exeter total hip arthroplasty in patients with small femurs - A minimal of 10 years follow-up
    Chiu, KH
    Shen, WY
    Cheung, KW
    Tsui, HF
    [J]. JOURNAL OF ARTHROPLASTY, 2005, 20 (03) : 275 - 281
  • [4] Exeter Short Stems Compared With Standard Length Exeter Stems Experience From the Australian Orthopaedic Association National Joint Replacement Registry
    Choy, Godwin G. H.
    Roe, John A.
    Whitehouse, Sarah L.
    Cashman, Kara S.
    Crawford, Ross W.
    [J]. JOURNAL OF ARTHROPLASTY, 2013, 28 (01) : 103 - 109
  • [5] Incomplete cement mantles in the sagittal femoral plane - An anatomical explanation
    Crawford, RW
    Psychoyios, V
    Gie, G
    Ling, R
    Murray, D
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1999, 70 (06): : 596 - 598
  • [6] 18 years of results with cemented primary hip prostheses in the Norwegian Arthroplasty Register Concerns about some newer implants
    Espehaug, Birgitte
    Furnes, Ove
    Engesaeter, Lars B.
    Havelin, Leif I.
    [J]. ACTA ORTHOPAEDICA, 2009, 80 (04) : 402 - 412
  • [7] SHEAR-STRENGTH OF TRABECULAR BONE FROM FEMUR, AND SOME FACTORS AFFECTING SHEAR-STRENGTH OF CEMENT-BONE INTERFACE
    HALAWA, M
    LEE, AJC
    LING, RSM
    VANGALA, SS
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1978, 92 (01) : 19 - 30
  • [8] The Exeter Universal stem - A minimum ten-year review from an independent centre
    Hook, S.
    Moulder, E.
    Yates, P. J.
    Burston, B. J.
    Whitley, E.
    Bannister, G. C.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (12): : 1584 - 1590
  • [9] Bivariate linkage study of proximal hip geometry and body size indices: The framingham study
    Karasik, D.
    Dupuis, J.
    Cupples, L. A.
    Beck, T. J.
    Mahaney, M. C.
    Havill, L. M.
    Kiel, D. P.
    Demissie, S.
    [J]. CALCIFIED TISSUE INTERNATIONAL, 2007, 81 (03) : 162 - 173
  • [10] The Long-Term Results of the Original Exeter Polished Cemented Femoral Component A Follow-up Report
    Ling, Robin S. M.
    Charity, John
    Lee, A. J. Clive
    Whitehouse, Sarah L.
    Timperley, A. John
    Gie, Graham A.
    [J]. JOURNAL OF ARTHROPLASTY, 2009, 24 (04) : 511 - 517