Myonecrosis following stent placement: Association between impaired TIMI myocardial perfusion grade and MRI visualization of microinfarction

被引:36
作者
Choi, JW
Gibson, CM
Murphy, SA
Davidson, CJ
Kim, RJ
Ricciardi, MJ
机构
[1] Northwestern Univ, Feinberg Sch Med, Div Cardiol, Chicago, IL 60611 USA
[2] Harvard Univ, Sch Med, Clin Res Inst, Boston, MA 02115 USA
[3] Northwestern Univ, Feinberg Cardiovasc Res Inst, Chicago, IL 60611 USA
关键词
coronary angioplasty; myocardial infarction; microcirculation;
D O I
10.1002/ccd.20024
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Contrast-enhanced cardiac MRI (ceMRI) and TIMI myocardial perfusion grade analysis (TMPG) are proven methods for visualization of microinfarction and assessment of microvascular perfusion, respectively. To determine whether microvascular obstruction accounts for procedure-related myonecrosis, 14 poststent patients, 9 with procedural CK-MB elevation and 5 controls, underwent ceMRI and TMPG. All had TIMI 3 flow pre-and poststent. TMPG was normal in 12/14 pre- and 7/14 poststent. Those with poststent decline in TMPG had higher CK-MB (median, 41.0 vs. 7.4 ng/mL; P = 0.01) and larger infarct mass (median, 3.1 vs. 0.89 g; P = 0.04). More extensive myonecrosis (CK-MB > 3 x normal; infarct mass > 3 g) was observed more frequently if there was a poststent decline in TMPG (3/3, 100%, vs. 2/11, 18.2%; P = 0.03). These data support the theory that distal embolization and microvascular obstruction are associated with myonecrosis following otherwise successful coronary stent placement and provide further insight into its pathophysiology. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:472 / 476
页数:5
相关论文
共 29 条
  • [1] Significance of mild transient release of creatine kinase-MB fraction after percutaneous coronary interventions
    Abdelmeguid, AE
    Topol, EJ
    Whitlow, PL
    Sapp, SK
    Ellis, SG
    [J]. CIRCULATION, 1996, 94 (07) : 1528 - 1536
  • [2] Effect of the distal-balloon protection system on microembolization during carotid stenting
    Al-Mubarak, N
    Roubin, GS
    Vitek, JJ
    Iyer, SS
    New, G
    Leon, MB
    [J]. CIRCULATION, 2001, 104 (17) : 1999 - 2002
  • [3] Randomized trial of a distal embolic protection device during percutaneous intervention of saphenous vein aorto-coronary bypass grafts
    Baim, DS
    Wahr, D
    George, B
    Leon, MB
    Greenberg, J
    Cutlip, DE
    Kaya, U
    Popma, JJ
    Ho, KKL
    Kuntz, RE
    [J]. CIRCULATION, 2002, 105 (11) : 1285 - 1290
  • [4] Myonecrosis after revascularization procedures
    Califf, RM
    Abdelmeguid, AE
    Kuntz, RE
    Popma, JJ
    Davidson, CJ
    Cohen, EA
    Kleiman, NS
    Mahaffey, KW
    Topol, EJ
    Pepine, CJ
    Lipicky, RJ
    Granger, CB
    Harrington, RA
    Tardiff, BE
    Crenshaw, BS
    Bauman, RP
    Zuckerman, BD
    Chaitman, BR
    Bittl, JA
    Ohman, EM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 241 - 251
  • [5] Prevention of distal embolization during saphenous vein graft lesion angioplasty - Experience with a new temporary occlusion and aspiration system
    Carlino, M
    De Gregorio, J
    Di Mario, C
    Anzuini, A
    Airoldi, F
    Albiero, R
    Briguori, C
    Dharmadhikari, A
    Sheiban, I
    Colombo, A
    [J]. CIRCULATION, 1999, 99 (25) : 3221 - 3223
  • [6] Relationship of TIMI myocardial perfusion grade to mortality after administration of thrombolytic drugs
    Gibson, CM
    Cannon, CP
    Murphy, SA
    Ryan, KA
    Mesley, R
    Marble, SJ
    McCabe, CH
    Van de Werf, F
    Braunwald, E
    [J]. CIRCULATION, 2000, 101 (02) : 125 - 130
  • [7] TIMI frame count: A quantitative method of assessing coronary artery flow
    Gibson, CM
    Cannon, CP
    Daley, WL
    Dodge, JT
    Alexander, B
    Marble, SJ
    McCabe, CH
    Raymond, L
    Fortin, T
    Poole, WK
    Braunwald, E
    [J]. CIRCULATION, 1996, 93 (05) : 879 - 888
  • [8] Relationship between TIMI frame count and clinical outcomes after thrombolytic administration
    Gibson, CM
    Murphy, SA
    Rizzo, MJ
    Ryan, KA
    Marble, SJ
    McCabe, CH
    Cannon, CP
    Van de Werf, F
    Braunwald, E
    [J]. CIRCULATION, 1999, 99 (15) : 1945 - 1950
  • [9] Effect of Eptifibatide on coronary flow reserve following coronary stent implantation -: (An ESPRIT substudy)
    Gibson, CM
    Cohen, DJ
    Cohen, EA
    Lui, HK
    Murphy, SA
    Marble, SJ
    Kitt, M
    Lorenz, T
    Tcheng, JE
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (11) : 1293 - 1295
  • [10] CHARACTERISTICS AND CONSEQUENCES OF MYOCARDIAL-INFARCTION AFTER PERCUTANEOUS CORONARY INTERVENTION - INSIGHTS FROM THE CORONARY ANGIOPLASTY VERSUS EXCISIONAL ATHERECTOMY TRIAL (CAVEAT)
    HARRINGTON, RA
    LINCOFF, AM
    CALIFF, RM
    HOLMES, DR
    BERDAN, LG
    OHANESIAN, MA
    KEELER, GP
    GARRATT, KN
    OHMAN, EM
    MARK, DB
    JACOBS, AK
    TOPOL, EJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (07) : 1693 - 1699