Venturi-Electrosonic Spray Ionization Cataluminescence Sensor Array for Saccharides Detection

被引:46
作者
Han, Jiaying [1 ]
Han, Feifei [1 ]
Ouyang, Jin [1 ]
Li, Quanmin [2 ]
Na, Na [1 ]
机构
[1] Beijing Normal Univ, Coll Chem, Beijing 100875, Peoples R China
[2] Gen Hosp Second Artillery, Dept Endocrinol, Beijing 100088, Peoples R China
关键词
AMBIENT MASS-SPECTROMETRY; BENZENE; PLASMA; SYSTEM;
D O I
10.1021/ac400948k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this article, a Venturi electrosonic spray ionization (V-ESSI) cataluminescence (CTL) sensor array was reported for discriminating saccharides in solution. Integrating electrosonic spray ionization (ESSI), a liquid system of Venturi self-pumping injection for the CTL reaction, was fabricated for enhancing CTL reactivity of aqueous samples. Comparing with simple Venturi injection by air and Venturi easy ambient sonic-spray ionization without electric assistance (V-EASI), the remarkable enhancement of CTL signals resulted from V-ESSI. This system showed higher cross-reactive CTL responses catalyzed by alkaline earth metal-nanomaterials than other catalysts, giving different signals for a given saccharide on different catalysts and different responses for different saccharides on the same catalyst. Then, a 4 x 2 CTL sensor array was used for obtaining "fingerprints" of distinct CTL response patterns. Analyzed by linear discriminant analysis (LDA), this V-ESSI CTL sensor array not only achieved the well discrimination of different saccharides (99.9% of total variation) but also discriminated four groups of urine sugar-level for urine samples from diabetic patients (98.1% of discrimination accuracy). It had good reproducibility and gave a linear range of 22.5-67558 mu g/mL (R > 0.99) for xylose with a detection limit of 7.4 mu g/mL on MgO. As a new artificial tongue, this system provided a simple, rapid, low cost, low energy consumption, and environmentally friendly pathway for aqueous sample discrimination. It has dramatically expanded applications of the CTL-based senor array and will be applicable to clinical diagnoses, environment monitoring, industrial controls, food industry, and various marine monitoring.
引用
收藏
页码:7738 / 7744
页数:7
相关论文
共 33 条
  • [1] Development of a Plasma-Assisted Cataluminescence System for Benzene, Toluene, Ethylbenzene, and Xylenes Analysis
    Almasian, Mohammad Reza
    Na, Na
    Wen, Fang
    Zhang, Sichun
    Zhang, Xinrong
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (09) : 3457 - 3459
  • [2] Wood typification by Venturi easy ambient sonic spray ionization mass spectrometry: the case of the endangered Mahogany tree
    Cabral, Elaine C.
    Simas, Rosineide C.
    Santos, Vanessa G.
    Queiroga, Carmen L.
    da Cunha, Valnei S.
    de Sa, Gilberto F.
    Darodad, Romeu J.
    Eberlin, Marcos N.
    [J]. JOURNAL OF MASS SPECTROMETRY, 2012, 47 (01): : 1 - 6
  • [3] Ultrasensitive Detection of Trace Protein by Western Blot Based on POLY-Quantum Dot Probes
    Chen, Wei
    Xu, Dinghua
    Liu, Liqiang
    Peng, Chifang
    Zhu, Yingyue
    Ma, Wei
    Bian, Ai
    Li, Zhe
    Yuanyuan
    Jin, Zhengyu
    Zhu, Shuifang
    Xu, Chuanlai
    Wang, Libing
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (21) : 9194 - 9198
  • [4] Ambient mass spectrometry
    Cooks, RG
    Ouyang, Z
    Takats, Z
    Wiseman, JM
    [J]. SCIENCE, 2006, 311 (5767) : 1566 - 1570
  • [5] Use of electronic nose technology to measure soil microbial activity through biogenic volatile organic compounds and gases release
    De Cesare, Fabrizio
    Di Mattia, Elena
    Pantalei, Simone
    Zampetti, Emiliano
    Vinciguerra, Vittorio
    Canganella, Francesco
    Macagnano, Antonella
    [J]. SOIL BIOLOGY & BIOCHEMISTRY, 2011, 43 (10) : 2094 - 2107
  • [6] A chemical-detecting system based on a cross-reactive optical sensor array
    Dickinson, TA
    White, J
    Kauer, JS
    Walt, DR
    [J]. NATURE, 1996, 382 (6593) : 697 - 700
  • [7] A CL mode detector for rapid catalyst selection and environmental detection fabricated by perovskite nanoparticles
    Fei Teng
    Tongguang Xu
    Yang Teng
    Shuhui Liang
    Bulgen Gauge
    Jie Lin
    Wenqing Ya
    Ruilong Zong
    Yongfa Zhu
    Zheng, Youfei
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2008, 42 (10) : 3886 - 3892
  • [8] ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES
    FENN, JB
    MANN, M
    MENG, CK
    WONG, SF
    WHITEHOUSE, CM
    [J]. SCIENCE, 1989, 246 (4926) : 64 - 71
  • [9] Development of multianalyte sensor arrays composed of chemically derivatized polymeric microspheres localized in micromachined cavities
    Goodey, A
    Lavigne, JJ
    Savoy, SM
    Rodriguez, MD
    Curey, T
    Tsao, A
    Simmons, G
    Wright, J
    Yoo, SJ
    Sohn, Y
    Anslyn, EV
    Shear, JB
    Neikirk, DP
    McDevitt, JT
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (11) : 2559 - 2570
  • [10] Amperometric glucose biosensor based on platinum nanoparticle encapsulated with a clay
    Han, Xiao
    Zhu, Yihua
    Yang, Xiaoling
    Li, Chunzhong
    [J]. MICROCHIMICA ACTA, 2010, 171 (3-4) : 233 - 239