Investigation of Mg/Al alloy sacrificial anode corrosion with Scanning Electrochemical Microscopy

被引:5
作者
Andras Kiss [1 ]
Souto, Ricardo M. [2 ]
Geza Nagy [1 ]
机构
[1] Univ Pecs, Fac Sci, Inst Chem, Dept Gen & Phys Chem, H-7622 Pecs, Hungary
[2] Univ La Laguna, Dept Phys Chem, E-38200 Tenerife, Canary Islands, Spain
关键词
Scanning Electrochemical Microscope; SECM; ion-selective microelectrode; ISME; galvanic corrosion; potentiometric tip; solid contact; ION-SELECTIVE ELECTRODE; SECM;
D O I
10.3311/PPch.2164
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Corrosion of Mg/Al alloy was investigated with the scanning electrochemical microscope (SECM) using a Mg2+ ion selective microelectrode (ISME) as measuring tip. Mg/Al alloys have practical application as sacrificial anodes to prevent the corrosion of various metals susceptible to corrosion. A typical application of such sacrificial anodes is in water boilers. A model (Mg/Al)/Fe target was fabricated using boiler sacrificial anode and high purity iron wires. Corrosion current was measured between the electrically connected galvanic pair, and Mg2+ ion flow rate was calculated with Faraday's law of electrolysis. However, Mg2+ flow rate could not be calculated with this method while the two metals were left electrically-disconnected. For this reason, fixed height lateral scans and retreating scans were performed above the Mg2+ sample with Mg2+ ion-selective electrodes employed as SECM tips. Mg2+ flow rate was estimated using the concentration profiles obtained with SECM. Relatively high-speed scans were possible with robust, solid contact Mg2+ micropipette electrodes, owing to their low resistance compared to conventional micropipettes of the same size.
引用
收藏
页码:11 / 14
页数:4
相关论文
共 8 条
[1]  
Bard A. J. A. J., SCANNING ELECTROCHEM
[2]   Investigation of concentration profiles inside operating biocatalytic sensors with scanning electrochemical microscopy (SECM) [J].
Csóka, B ;
Kovács, B ;
Nagy, G .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (2-3) :141-149
[3]   Imaging metastable pits on austenitic stainless steel in situ at the open-circuit corrosion potential [J].
González-García, Y ;
Burstein, GT ;
González, S ;
Souto, RM .
ELECTROCHEMISTRY COMMUNICATIONS, 2004, 6 (07) :637-642
[4]  
Gupta Arjun K, 2004, HDB BETA DISTRIBUTIO
[5]   Solid contact micropipette ion selective electrode for potentiometric SECM [J].
Gyetvai, Gergely ;
Sundblom, Soren ;
Nagy, Livia ;
Ivaska, Ari ;
Nagy, Geza .
ELECTROANALYSIS, 2007, 19 (10) :1116-1122
[6]   Solid Contact Micropipette Ion Selective Electrode II: Potassium Electrode for SECM and In Vivo Applications [J].
Gyetvai, Gergely ;
Nagy, Livia ;
Ivaska, Ari ;
Hernadi, Istvan ;
Nagy, Geza .
ELECTROANALYSIS, 2009, 21 (17-18) :1970-1976
[7]   Evaluation of the corrosion performance of coil-coated steel sheet as studied by scanning electrochemical microscopy [J].
Souto, R. M. ;
Gonzalez-Garcia, Y. ;
Gonzalez, S. .
CORROSION SCIENCE, 2008, 50 (06) :1637-1643
[8]   DEVELOPMENT OF SOLID CONTACT MICROPIPETTE Zn-ION SELECTIVE ELECTRODE FOR CORROSION STUDIES [J].
Varga, Agnes ;
Nagy, Livia ;
Izquierdo, Javier ;
Bitter, Istvan ;
Souto, Ricardo M. ;
Nagy, Geza .
ANALYTICAL LETTERS, 2011, 44 (18) :2876-2886