A new source of variance in visual acuity

被引:15
|
作者
Coppens, JE [1 ]
van den Berg, TJTP [1 ]
机构
[1] Royal Netherlands Acad Arts & Sci, Netherlands Ophthalm Res Inst, NL-1105 BA Amsterdam, Netherlands
关键词
visual acuity; blur; scale invariance; Gaussian blur; intrinsic blur;
D O I
10.1016/j.visres.2003.11.008
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
In an ocularly healthy population, decimal visual acuities range from 1 to 3. We wondered how this spread can be understood. Using a maximum likelihood adaptive procedure, "visual acuity" was measured in a healthy population with four stimulus sets: unblurred Landolt Cs and Cs blurred with a Gaussian of width sigma = 2.12', 4.24' and 8.48'. A simple model based on scale invariance of the visual system was applied. This model was tested by predicting the outcomes of the 2.12' measurements based on the other measurements. The minimum angle of resolution (MAR) values found are closely proportional to "equivalent blur" of the stimulus defined as the convolution of a value for intrinsic blur of the eye and added blur. The proportionality factor is different between individuals and is an important source for the spread in acuities found in a healthy population. The differences between the proportionality factors are, interpreted as differences in the (neuronal) judgment capability between individuals. The total standard deviation of log(MAR) found in our study was 0.11. This value can be subdivided in 0.06 for the (neuronal) judgment capability, 0.08 for the intrinsic retinal blur and a measurement accuracy of 0.04. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:951 / 958
页数:8
相关论文
共 50 条
  • [41] THE VISUAL-ACUITY OF THE LYNX
    MAFFEI, L
    FIORENTINI, A
    BISTI, S
    VISION RESEARCH, 1990, 30 (04) : 527 - 528
  • [42] Visual acuity in children with hydrocephalus
    Oud, KT
    Steggerda, SJ
    Nanninga-Van den Neste, VM
    Gooskens, RH
    Van Nieuwenhuizen, O
    NEURO-OPHTHALMOLOGY, 1999, 21 (02) : 75 - 82
  • [43] Snellen visual acuity evaluation
    Zapparoli, Marcio
    Klein, Fernando
    Moreira, Hamilton
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2009, 72 (06) : 783 - 788
  • [44] Visual acuity in premature infants
    Spierer, A
    Royzman, Z
    Kuint, J
    OPHTHALMOLOGICA, 2004, 218 (06) : 397 - 401
  • [45] VISUAL-ACUITY ASSESSMENT
    WEATHERILL, JR
    EYE, 1993, 7 : 26 - 28
  • [46] Strategies of visual acuity assessment
    Gräf, M
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2004, 221 (07) : 557 - 565
  • [47] Phenomenological model of visual acuity
    Gomez-Pedrero, Jose A.
    Alonso, Jose
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (12)
  • [48] Repeatability of visual acuity measurement
    Raasch, TW
    Bailey, IL
    Bullimore, MA
    OPTOMETRY AND VISION SCIENCE, 1998, 75 (05) : 342 - 348
  • [49] CWhatUC: A visual acuity simulator
    Garcia, DD
    Barsky, BA
    Klein, SA
    OPHTHALMIC TECHNOLOGIES VIII, PROCEEDINGS OF, 1998, 3246 : 290 - 298
  • [50] Visual Acuity with Astigmatic Blur
    Atchison, David A.
    Mathur, Ankit
    OPTOMETRY AND VISION SCIENCE, 2011, 88 (07) : 798 - 805