Density weighted turbo spin echo imaging

被引:4
|
作者
Zeller, Mario [1 ]
Gutberlet, Marcel [2 ]
Staeb, Daniel [1 ]
Ritter, Christian Oliver [1 ]
Beer, Meinrad [1 ]
Hahn, Dietbert [1 ]
Koestler, Herbert [1 ,3 ]
机构
[1] Univ Wurzburg, Inst Radiol, Univ Clin, D-97080 Wurzburg, Germany
[2] Hannover Med Sch, Dept Radiol, Hannover, Germany
[3] Univ Wurzburg, Comprehens Heart Failure Ctr CHFC, D-97080 Wurzburg, Germany
关键词
density weighting; variable density; turbo spin echo; spatial response function; modulation transfer function; SNR; RELAXATION-TIMES; MAGNETIC-FIELD; ACQUISITION; RARE; MR;
D O I
10.1002/jmri.23872
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To optimize the spatial response function (SRF) while maintaining optimal signal to noise ratio (SNR) in T2 weighted turbo spin echo (TSE) imaging by prospective density weighting. Materials and Methods Density weighting optimizes the SRF by sampling the k-space with variable density without the need of retrospective filtering, which would typically result in nonoptimal SNR. For TSE, the T2 decay needs to be considered when calculating an optimized sampling pattern. Simulations were carried out and T2 weighted in vivo TSE measurements were performed on a 3 Tesla MRI system. To evaluate the SNR, reversed centric density weighted and retrospectively filtered Cartesian acquisitions with identical measurement parameters and SRFs were compared with TEeff = 90 ms and a density weighted k-space sampling optimized to yield a Kaiser function for SRF side lobe suppression for white matter. Results Density weighting of a reversed centric reordering scheme resulted in an SNR increase of (43 +/- 13)% compared with the Cartesian acquisition with retrospective filtering while maintaining comparable contrast behavior. Conclusion Density weighting is applicable to TSE imaging and results in significantly increased SNR. The gain can be used to shorten the measurement time, which suggests applying density weighting in both time and SNR constrained MRI. J. Magn. Reson. Imaging 2013;37:965973. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:965 / 973
页数:9
相关论文
共 50 条
  • [41] Is simultaneous multisection turbo spin echo ready for clinical MRI? A feasibility study on fast imaging of knee lesions
    Li, X.
    Peng, Z.
    Sun, Y.
    Cui, J.
    CLINICAL RADIOLOGY, 2020, 75 (03) : 238.e21 - 238.e30
  • [42] Bone marrow lesions: Evaluation with fat-suppression turbo spin echo MR imaging at 0.5 T
    Chrysikopoulos, H
    Pappas, J
    Papanikolaou, N
    Papazoglou, A
    Roussakis, A
    Andreou, J
    EUROPEAN RADIOLOGY, 1996, 6 (06) : 895 - 899
  • [43] Optimal MR protocol for hepatic hemangiomas - Comparison of conventional spin-echo sequences with T2-weighted turbo spin-echo and serial gradient-echo (FLASH) sequences with gadolinium enhancement
    Kim, TK
    Choi, BI
    Han, JK
    Jang, HJ
    Han, MC
    ACTA RADIOLOGICA, 1997, 38 (04) : 565 - 571
  • [44] Comparison of DWI Methods in the Pediatric Brain: PROPELLER Turbo Spin-Echo Imaging Versus Readout-Segmented Echo-Planar Imaging Versus Single-Shot Echo-Planar Imaging
    Kim, Tae-Hyung
    Baek, Moon-Young
    Park, Ji Eun
    Ryu, Young Jin
    Cheon, Jung-Eun
    Kim, In-One
    Choi, Young Hun
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (06) : 1352 - 1358
  • [45] A 2D spiral turbo-spin-echo technique
    Li, Zhiqiang
    Karis, John P.
    Pipe, James G.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (05) : 1989 - 1996
  • [46] Functional turbo spin echo magnetic resonance imaging versus tomography for evaluating cervical spine involvement in rheumatoid arthritis
    Oostveen, JCM
    Roozeboom, AR
    van de Laar, MAFJ
    Heeres, J
    den Boer, JA
    Lindeboom, SF
    SPINE, 1998, 23 (11) : 1237 - 1244
  • [47] Increased-contrast, high-spatial-resolution, diffusion-weighted, spin-echo, echo-planar imaging
    Thompson, MR
    Venkatesan, R
    Kuppusamy, K
    Celik, A
    Lin, WL
    Kido, DK
    Haacke, EM
    RADIOLOGY, 1999, 210 (01) : 253 - 259
  • [48] MRT versus CT in the diagnosis of pneumonia:: evaluation of a T2-weighted ultrafast turbo-spin-echo sequence (UTSE).
    Leutner, C
    Gieseke, J
    Lutterbey, G
    Kuhl, CK
    Flacke, S
    Glasmacher, A
    Theisen, A
    Wardelmann, E
    Grohe, C
    Schild, HH
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (05): : 449 - 456
  • [49] Improved fat-suppression homogeneity with mDIXON turbo spin echo (TSE) in pediatric spine imaging at 3.0 T
    Pokorney, Amber L.
    Chia, Jonathan M.
    Pfeifer, Cory M.
    Miller, Jeffrey H.
    Hu, Houchun H.
    ACTA RADIOLOGICA, 2017, 58 (11) : 1386 - 1394
  • [50] Intuitive design guidelines for fast spin echo imaging with variable flip angle echo trains
    Lebel, R. Marc
    Wilman, Alan H.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (05) : 972 - 975