Density weighted turbo spin echo imaging

被引:4
|
作者
Zeller, Mario [1 ]
Gutberlet, Marcel [2 ]
Staeb, Daniel [1 ]
Ritter, Christian Oliver [1 ]
Beer, Meinrad [1 ]
Hahn, Dietbert [1 ]
Koestler, Herbert [1 ,3 ]
机构
[1] Univ Wurzburg, Inst Radiol, Univ Clin, D-97080 Wurzburg, Germany
[2] Hannover Med Sch, Dept Radiol, Hannover, Germany
[3] Univ Wurzburg, Comprehens Heart Failure Ctr CHFC, D-97080 Wurzburg, Germany
关键词
density weighting; variable density; turbo spin echo; spatial response function; modulation transfer function; SNR; RELAXATION-TIMES; MAGNETIC-FIELD; ACQUISITION; RARE; MR;
D O I
10.1002/jmri.23872
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To optimize the spatial response function (SRF) while maintaining optimal signal to noise ratio (SNR) in T2 weighted turbo spin echo (TSE) imaging by prospective density weighting. Materials and Methods Density weighting optimizes the SRF by sampling the k-space with variable density without the need of retrospective filtering, which would typically result in nonoptimal SNR. For TSE, the T2 decay needs to be considered when calculating an optimized sampling pattern. Simulations were carried out and T2 weighted in vivo TSE measurements were performed on a 3 Tesla MRI system. To evaluate the SNR, reversed centric density weighted and retrospectively filtered Cartesian acquisitions with identical measurement parameters and SRFs were compared with TEeff = 90 ms and a density weighted k-space sampling optimized to yield a Kaiser function for SRF side lobe suppression for white matter. Results Density weighting of a reversed centric reordering scheme resulted in an SNR increase of (43 +/- 13)% compared with the Cartesian acquisition with retrospective filtering while maintaining comparable contrast behavior. Conclusion Density weighting is applicable to TSE imaging and results in significantly increased SNR. The gain can be used to shorten the measurement time, which suggests applying density weighting in both time and SNR constrained MRI. J. Magn. Reson. Imaging 2013;37:965973. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:965 / 973
页数:9
相关论文
共 50 条
  • [1] CINE Turbo Spin Echo Imaging
    Mendes, Jason
    Parker, Dennis L.
    Hulet, Jordan
    Treiman, Gerald S.
    Kim, Seong-Eun
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (05) : 1286 - 1292
  • [2] Experimental O-Space Turbo Spin Echo Imaging
    Wang, Haifeng
    Tam, Leo
    Kopanoglu, Emre
    Peters, Dana C.
    Constable, R. Todd
    Galiana, Gigi
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (04) : 1654 - 1661
  • [3] Diffusion-weighted imaging of the brain at 7 T with echo-planar and turbo spin echo sequences: preliminary results
    Sigmund, Eric E.
    Gutman, David
    MAGNETIC RESONANCE IMAGING, 2011, 29 (06) : 752 - 765
  • [4] RARE/Turbo Spin Echo Imaging with Simultaneous Multislice Wave-CAIPI
    Gagoski, Borjan A.
    Bilgic, Berkin
    Eichner, Cornelius
    Bhat, Himanshu
    Grant, P. Ellen
    Wald, Lawrence L.
    Setsompop, Kawin
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (03) : 929 - 938
  • [5] Intravoxel Incoherent Motion Diffusion-Weighted Imaging of Lung Cancer: Comparison Between Turbo Spin-Echo and Echo-Planar Imaging
    Wan, Qi
    Lei, Qiang
    Wang, Peng
    Hu, Jianfeng
    Zhang, Tianjing
    Yu, Deng
    Li, Xinchun
    Liang, Changhong
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (03) : 334 - 340
  • [6] Comparison of Turbo Spin Echo and Echo Planar Imaging for intravoxel incoherent motion and diffusion tensor imaging of the kidney at 3 Tesla
    Hilbert, Fabian
    Wech, Tobias
    Neubauer, Henning
    Veldhoen, Simon
    Bley, Thorsten Alexander
    Koestler, Herbert
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2017, 27 (03): : 193 - 201
  • [7] Single-Shot Turbo Spin-Echo Diffusion-Weighted Imaging for Retinoblastoma: Initial Experience
    de Graaf, P.
    Pouwels, P. J. W.
    Rodjan, F.
    Moll, A. C.
    Imhof, S. M.
    Knol, D. L.
    Sanchez, E.
    van der Valk, P.
    Castelijns, J. A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (01) : 110 - 118
  • [8] Diffusion sensitivity of turbo spin echo sequences
    Weigel, Matthias
    Hennig, Juergen
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (06) : 1528 - 1537
  • [9] Liver T2-weighted MR imaging: Comparison of fast and conventional half-Fourier single-shot turbo spin-echo, breath-hold turbo spin-echo, and respiratory-triggered turbo spin-echo sequences
    Tang, Y
    Yamashita, Y
    Namimoto, T
    Abe, Y
    Takahashi, M
    RADIOLOGY, 1997, 203 (03) : 766 - 772
  • [10] Comparison between turbo spin-echo and echo planar diffusion-weighted imaging of the female pelvis with 3T MRI
    Yoshizako, Takeshi
    Yoshida, Rika
    Asou, Hiroya
    Nakamura, Megumi
    Kitagaki, Hajime
    ACTA RADIOLOGICA OPEN, 2021, 10 (02)