Reproducibility of isokinetic knee testing using the novel isokinetic SMM iMoment dynamometer

被引:19
|
作者
Kambic, Tim [1 ,2 ]
Lainscak, Mitja [3 ,4 ]
Hadzic, Vedran [2 ]
机构
[1] Gen Hosp Murska Sobota, Dept Res & Educ, Murska Sobota, Slovenia
[2] Univ Ljubljana, Fac Sport, Lab Sports & Med Diagnost, Ljubljana, Slovenia
[3] Gen Hosp Murska Sobota, Div Cardiol, Murska Sobota, Slovenia
[4] Univ Ljubljana, Fac Med, Ljubljana, Slovenia
来源
PLOS ONE | 2020年 / 15卷 / 08期
关键词
RELIABILITY; STRENGTH; EXTENSION; QUADRICEPS; MOTION;
D O I
10.1371/journal.pone.0237842
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Isokinetic dynamometry is the gold standard for testing maximal strength in elite sport and rehabilitation settings. To be clinically useful, such tests should be valid and reliable. Despite some evidence regarding the relative test vs retest reliability of knee dynamometry, there is still a paucity of research regarding the absolute reliability parameters. The purpose of this study was to assess the absolute and relative intra-device reproducibility of isokinetic knee flexion and extension using the novel SMM iMoment dynamometer. A total of 19 participants (13 males and 6 females, aged 24 (2) years, height 178 (9) cm and weight 76 (11) kg) performed two identical knee isokinetic tests with at least a week of rest between measurements. Peak torque of knee extension and flexion were determined at 60 degrees/s. Moderate (0.892) to excellent (0.988) relative reliability using the intraclass correlation coefficient (ICC) was obtained for peak knee torque. Absolute reliability assessed with a standard error of measurement (SEM %) was low, ranging from 2.54% to 6.93%, whereas the smallest real difference (SRD %) was moderate, ranging from 7.04% to 19.22%. Furthermore, there were no significant correlations between means and differences of two measurements, and Bland-Altman plots also showed no signs of heteroscedasticity. Our measurement protocol established the moderate to excellent reliability of the novel SMM iMoment isokinetic dynamometer. Therefore, this dynamometer can be applied in sport rehabilitation settings to measure maximal knee strength.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Application of isokinetic dynamometer in treatment of knee joint contracture by static progressive stretch
    Cai, B. (orthorehab_9th@hotmail.com), 1600, Shanghai Jiaotong University School of Medicine (27):
  • [22] INFLUENCE OF THE DYNAMOMETER DRIVING MECHANISM ON THE ISOKINETIC TORQUE ANGLE CURVE OF KNEE EXTENSORS
    STAM, HJ
    BINKHORST, RA
    VANNIEUWENHUYZEN, JF
    SNIJDERS, CJ
    CLINICAL BIOMECHANICS, 1993, 8 (02) : 91 - 94
  • [23] Does knee joint alignment with the axis of the isokinetic dynamometer affect peak torque?
    Houweling, Taco A. W.
    Hamzeh, Maher A.
    ISOKINETICS AND EXERCISE SCIENCE, 2010, 18 (04) : 217 - 221
  • [24] Comparing isometric and isokinetic peak strength values using slow speeds on a Cybex 340 isokinetic dynamometer machine
    Burkett, LN
    Alvar, B
    Irvin, J
    ISOKINETICS AND EXERCISE SCIENCE, 2000, 8 (04) : 213 - 215
  • [25] A Novel Two-Velocity Method for Elaborate Isokinetic Testing of Knee Extensors
    Grbic, Vladimir
    Djuric, Sasa
    Knezevic, Olivera M.
    Mirkov, Dragan M.
    Nedeljkovic, Aleksandar
    Jaric, Slobodan
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2017, 38 (10) : 741 - 746
  • [26] INFLUENCE OF ISOKINETIC TESTING ON MEASUREMENTS OF ANTERIOR KNEE LAXITY
    BUCHANAN, PA
    KEGERREIS, ST
    SMITH, BA
    PHYSICAL THERAPY, 1987, 67 (05): : 751 - 751
  • [27] Factors influencing the reproducibility of isokinetic knee flexion and extension test findings
    Alt, Tobias
    Knicker, Axel J.
    Strueder, Heiko K.
    ISOKINETICS AND EXERCISE SCIENCE, 2014, 22 (04) : 333 - 342
  • [28] COMPARATIVE STUDY ON THE ASSESSMENT OF THE STRENGTH OF THE KNEE EXTENSOR AND FLEXOR MUSCLES BY HAND-HELD DYNAMOMETER AND ISOKINETIC DYNAMOMETER
    Muff, Guillaume
    Masat, Julien
    Lecocq, Jehan
    Meyer, Alain
    Isner-Horobeti, Marie-Eve
    ACTA PHYSIOLOGICA, 2015, 214 : 46 - 46
  • [29] Continuous versus separate isokinetic test protocol:: The effect of estradiol on the reproducibility of concentric and eccentric isokinetic measurements in knee muscles
    Gür, H
    Akova, B
    Kücükoglu, S
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1999, 80 (09): : 1024 - 1029
  • [30] Ability of Isokinetic Dynamometer to Predict Isotonic Knee Extension 1-Repetition Maximum
    Lesnak, Joseph B.
    Anderson, Dillon T.
    Farmer, Brooke E.
    Katsavelis, Dimitrios
    Grindstaff, Terry L.
    JOURNAL OF SPORT REHABILITATION, 2020, 29 (05) : 616 - 620