Passive cooling roof design under Jordanian climate

被引:18
|
作者
Hamdan, Mohammad A. [1 ]
Yamin, Jehad [2 ]
Hafez, Eman M. Abdel [1 ]
机构
[1] Univ Jordan, Dept Mech Engn, Amman 11942, Jordan
[2] Al Zaytoonah Univ, Dept Mech Engn, Amman 11733, Jordan
关键词
Passive cooling; Roof structure; Energy saving; Thermal comfort; BUILDINGS;
D O I
10.1016/j.scs.2011.10.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Four identical test structures each having dimensions 1m x 0.6m x 1m have been fabricated. All the four sides of the test structure were made by using mild steel angle and galvanized steel sheet. A 0.08 m layer thickness of reinforced cement concrete CRCC roof was casted over each one. Different passive techniques were used over the roof for cooling the environment inside test structure; these techniques are painting of roof with white cement, pieces of glass and clay layer. One of the four structures is without any material over the cement concrete roof which is to be a reference one to compare other system results with it. The four structures were constructed, and installed next to each other so that they may be tested simultaneously. Under local climate the test procedure was casted out by measuring the inside, outside, wet and dry temperatures and also by measuring the relative humidity. The structure with clay on top of the concrete was found to be the most efficient structure for cooling purpose. Finally the thickness of clay layer was varied so as to find optimum layer thickness for cooling purpose. It was found that the cooling efficiency of the clay structure increases with thickness up to 0.05 m, beyond which the inside temperature remains constant. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:26 / 29
页数:4
相关论文
共 50 条
  • [31] Summer period analysis of the performance of a planted roof as a passive cooling technique
    Theodosiou, TG
    ENERGY AND BUILDINGS, 2003, 35 (09) : 909 - 917
  • [32] Application of radiant cooling as a passive cooling option in hot humid climate
    Vangtook, Prapapong
    Chirarattananon, Surapong
    BUILDING AND ENVIRONMENT, 2007, 42 (02) : 543 - 556
  • [33] Modelling and performance assessment of a Tri-Generation cooling system using two adsorption chillers under Jordanian climate
    Younes, Mai Bani
    Abu Shaban, Nabeel
    Altork, Yousef
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 44
  • [34] Thermal and moisture characteristics of moist porous mediums with passive evaporation cooling under natural climate
    Meng, QL
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 1187 - 1193
  • [35] Roof design considerations for cold climate environments
    Allaire, Marc G.
    Interface (Raleigh, North Carolina), 1998, 16 (01): : 5 - 10
  • [36] New design of solar roof for household heating and cooling
    Juanico, L. E.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2010, 35 (11) : 5823 - 5826
  • [37] Daytime Passive Radiative Cooling in a Humid Subtropical Climate
    Tso, Edwin C. Y.
    4TH THERMAL AND FLUIDS ENGINEERING CONFERENCE, ASTFE 2019, 2019,
  • [38] Impact of climate warming on passive night cooling potential
    Artmann, N.
    Gyalistras, D.
    Manz, H.
    Heiselberg, P.
    BUILDING RESEARCH AND INFORMATION, 2008, 36 (02): : 111 - 128
  • [39] Selection of suitable passive cooling strategy for a subtropical climate
    Ahmed A.-S.F.
    Khan K.-M.M.K.
    Maung Than Oo A.-A.
    Maung Than Oo A.-A.
    Rasul R.-M.G.
    International Journal of Mechanical and Materials Engineering, 2014, 9 (1)
  • [40] The investigation of green roof and white roof cooling potential on single storey residential building in the Malaysian climate
    Ismail, Asmat
    Samad, Muna Hanim Abdul
    Rahman, Abdul Malek Abdul
    World Academy of Science, Engineering and Technology, 2011, 76 : 129 - 137