Magnetic field sensitive polymeric actuators

被引:23
|
作者
Zrinyi, M [1 ]
Szabó, D [1 ]
Barsi, L [1 ]
机构
[1] Tech Univ Budapest, Dept Phys Chem, H-1521 Budapest, Hungary
关键词
D O I
10.1177/1045389X9800900814
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper reports on the magnetoelastic properties of a recently developed soft and wet material; the magnetic field sensitive polymer gel. It is a polymer network swollen by a ferrofluid. The peculiar magnetoelastic properties may be used to create a wide range of motions and to control the shape change and movement. An understanding of magnetoelastic coupling in gels will hasten the application of gel engineering to switches, sensors, micromachines, biomimetic energy-transducing devices and controlled delivery systems.
引用
收藏
页码:667 / 671
页数:5
相关论文
共 50 条
  • [31] Failure Analysis of Linear Electromagnetic Actuators Under Disturbing Magnetic Field
    Wang, Rumeng
    Yang, Yong
    Zhang, Ming
    Lu, Yiwei
    Pan, Yuan
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2022, 50 (11) : 4267 - 4273
  • [32] Ferrogel: a magnetic field sensitive elastic material
    Barsi, L
    Szabo, D
    Buki, A
    Zrinyi, M
    MAGYAR KEMIAI FOLYOIRAT, 1997, 103 (09): : 401 - 410
  • [33] HIGHLY SENSITIVE STATIC MAGNETIC FIELD DETECTOR
    DUMIN, DJ
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1962, 50 (08): : 1825 - &
  • [34] Modeling the hyperelasticity of magnetic field sensitive gels
    Voltairas, PA
    Fotiadis, DI
    Massalas, CV
    JOURNAL OF APPLIED PHYSICS, 2003, 93 (06) : 3652 - 3656
  • [35] Magnetic-field induced shape memory hydrogels for deformable actuators
    Tian, Ye
    Xu, Zhirui
    Qi, Hao
    Lu, Xiaojun
    Jiang, Ting
    Wang, Liqian
    Zhang, Guang
    Xiao, Rui
    Wu, Huaping
    SOFT MATTER, 2024, 20 (27) : 5314 - 5323
  • [36] SYNTHESIS OF MAGNETIC THERMO-SENSITIVE POLYMERIC MICROSPHERES FOR CONTROLLED RELEASE VIA MAGNETIC INDUCTION
    Cai, Li-feng
    Wen, Yu-qian
    Lin, Zhi-yong
    Qian, Hao
    Deng, Xiong-wei
    ACTA POLYMERICA SINICA, 2012, (08) : 846 - 851
  • [37] Bio-mimetic actuators: polymeric Pseudo muscular Actuators and pneumatic Muscle Actuators for biological emulation
    Caldwell, DC
    Tsagarakis, N
    Medrano-Cerda, GA
    MECHATRONICS, 2000, 10 (4-5) : 499 - 530
  • [38] Improvement of average magnetic field measurement based on magnetic-field-sensitive Ramsey fringes
    Zhao, Weijing
    Qian, Wang
    Lv, Desheng
    Wei, Rong
    OPTICS LETTERS, 2022, 47 (08) : 2073 - 2076
  • [39] Magnetic field measurement by weak magnetic-sensitive Zeeman splitting
    Dong, Richang
    Wei, Rong
    Du, Yuanbo
    Zou, Fan
    Lin, Jinda
    Wang, Yuzhu
    APPLIED PHYSICS LETTERS, 2015, 106 (15)
  • [40] Self-Healing Polymeric Soft Actuators
    Bonardd, Sebastian
    Nandi, Mridula
    Hernandez Garcia, Jose Ignacio
    Maiti, Binoy
    Abramov, Alex
    Diaz Diaz, David
    CHEMICAL REVIEWS, 2023, 123 (02) : 736 - 810