The Digital-Analog SiPM Approach: a Story of Electronic and Excess Noise

被引:5
作者
Decker, Savannah M. [1 ]
Pizzichemi, Marco [2 ]
Polesel, Andrea
Paganoni, Marco [3 ]
Auffray, Etiennette [2 ]
Gundacker, Stefan [2 ,3 ]
机构
[1] Boston Univ, Boston, MA 02215 USA
[2] European Org Nucl Res, Geneva, Switzerland
[3] Univ Milano Bicocca, Milan, Italy
来源
2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2019年
关键词
D O I
10.1109/nss/mic42101.2019.9059792
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Modern PET detectors rely on fast and accurate timing performances in order to provide improved lesion detectability and reduced patient scan times. Optimizing the coincidence timing resolution (CTR) is an important facet that helps achieve high PET detector performance. On the way of improving the CTR to sub-100 ps, and ultimately to 10 ps, research on all detector components is necessary, including the scintillator, photodetector and electronic readout. The digital SiPM, where each single photon avalanche diode (SPAD) is connected to its own readout, has gained a lot of attention as the ultimate photodetector. However, extended power consumption and the enormous number of channels makes the realization challenging. Hence, in this contribution we investigate a semi-digital approach, realized with the pixelation of an analog SiPM. We tested a single SiPM from HPK (S13360-6075V) compared to a 2x2 SiPM array (S13361-3075N-02) and a 3x3 SiPM array (S13361-2075N-03) with a 6x6x3 mm(3) crystal and a 6x6x20 mm(3) crystal, readout by our in-house developed acquisition system employing NINO as front-end ASIC. Preliminary results show that the single SiPM array routinely performed better than the pixelated arrays while reading each of the individual SiPMs independently, correcting for time walk and properly combining the time-stamps. A minimum CTR value of 117 +/- 5 ps was achieved using the single SiPM array with the 6x6x3 mm(3) crystal for the NINO electronics readout. Using a HF bipolar transistor readout, a similar trend was observed, with a minimum CTR of 116 +/- 5 ps for the single array and the 6x6x3 mm(3) crystal. A-priori this result is surprising because, due to the lower capacitance of the smaller SiPMs, electronic noise should be reduced leading to better timing. The most probable explanation for this counter-intuitive result is the 4 or 9 times lower number of scintillation photons generating each SiPM signal, which together with correlated noise sources (optical cross-talk) leads to excess noise, especially in the applied leading edge time discrimination.
引用
收藏
页数:5
相关论文
共 7 条
  • [1] Understanding and simulating SiPMs
    Acerbi, Fabio
    Gundacker, Stefan
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 926 : 16 - 35
  • [2] NINO: an ultra-fast and low-power front-end amplifier/discriminator ASIC designed for the multigap resistive plate chamber
    Anghinolfi, F
    Jarron, P
    Martemiyanov, AN
    Usenko, E
    Wenninger, H
    Williams, MCS
    Zichichi, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 533 (1-2) : 183 - 187
  • [3] Electrical Characterization of Silicon Photo-Multiplier Detectors for Optimal Front-End Design
    Corsi, F.
    Marzocca, C.
    Perrotta, A.
    Dragone, A.
    Foresta, M.
    Del Guerra, A.
    Marcatili, S.
    Llosa, G.
    Collazzuol, G.
    Betta, G. F. Dalla
    Dinu, N.
    Piemonte, C.
    Pignatel, G. U.
    Levi, G.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1276 - 1280
  • [4] On the comparison of analog and digital SiPM readout in terms of expected timing performance
    Gundacker, S.
    Auffray, E.
    Jarron, P.
    Meyer, T.
    Lecoq, P.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 787 : 6 - 11
  • [5] High-frequency SiPM readout advances measured coincidence time resolution limits in TOF-PET
    Gundacker, Stefan
    Turtos, Rosana Martinez
    Auffray, Etiennette
    Paganoni, Marco
    Lecoq, Paul
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (05)
  • [6] On light sharing TOF-PET modules with depth of interaction and 157 ps FWHM coincidence time resolution
    Pizzichemi, M.
    Polesel, A.
    Stringhini, G.
    Gundacker, S.
    Lecoq, P.
    Tavernier, S.
    Paganoni, M.
    Auffray, E.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (15)
  • [7] Simulation of Silicon Photomultiplier Signals
    Seifert, Stefan
    van Dam, Herman T.
    Huizenga, Jan
    Vinke, Ruud
    Dendooven, Peter
    Loehner, Herbert
    Schaart, Dennis R.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (06) : 3726 - 3733