摘要
We present the implementation of the ultraviolet (UV) radiation dose measurement system at the Laboratorio de Dosimetria Optica (LDOS) of the Centro Nacional de Metrologia (CENAM). The U`V dose measurement ranges established so far cover from 12 Jm(-2) to 7 256 Jm(-2) and from 171 Jm(-2) to 102 842 Jm(-2), for 254 nm and 365 nm, respectively; corresponding to two emission lines of an arc Hg(Xe) lamp. Those dose ranges can be reached with exposure times from 2 s to 10 min and the reference dose uncertainty has been estimated to be of 5,4 %.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] DOSE-DOSE-RATE RESPONSES OF SHRIMP LARVAE TO UV-B RADIATION
    DAMKAER, DM
    DEY, DB
    HERON, GA
    OECOLOGIA, 1981, 48 (02) : 178 - 182
  • [32] UV index forecasts and measurements of health-effective radiation
    Feister, Uwe
    Laschewski, Gudrun
    Grewe, Rolf-Dieter
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 2011, 102 (01) : 55 - 68
  • [33] Radiochromic gels for UV radiation measurements in 3D
    Kozicki, Marek
    Kwiatos, Klaudia
    Dudek, Mariusz
    Stempien, Zbigniew
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2018, 351 : 197 - 207
  • [34] Impact of clouds with limited horizontal extent on UV radiation measurements
    Davis, JM
    Slusser, JR
    ULTRAVIOLET GROUND- AND SPACE-BASED MEASUREMENTS, MODELS, AND EFFECTS IV, 2004, 5545 : 36 - 42
  • [35] A Plant-Based Sensor for UV-A Radiation Measurements
    Trigona, Carlo
    Napoli, Giuseppe
    Pasquale, Stefania
    Puglisi, Ivana
    Baglieri, Andrea
    Gueli, Anna Maria
    2021 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC 2021), 2021,
  • [36] INSTRUMENTS FOR BROAD-BAND UV-RADIATION MEASUREMENTS
    FEISTER, U
    GRASNICK, KH
    GREWE, R
    SOLAR ENERGY, 1992, 49 (06) : 535 - 540
  • [37] Single dose radiation is more effective for the UV-induced activation and proliferation of melanocytes than fractionated dose radiation
    An, HT
    Yoo, JY
    Lee, MK
    Shin, MH
    Rhie, GE
    Seo, JY
    Chung, JH
    Eun, HC
    Cho, KH
    PHOTODERMATOLOGY PHOTOIMMUNOLOGY & PHOTOMEDICINE, 2001, 17 (06) : 266 - 271
  • [38] DETAILED MEASUREMENTS OF ELECTRON DOSE DISTRIBUTIONS IN RADIATION PROCESSING
    OPROIU, C
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (08): : 1057 - 1057
  • [39] ACCREDITED DOSE MEASUREMENTS FOR VALIDATION OF RADIATION STERILIZED PRODUCTS
    MILLER, A
    RADIATION PHYSICS AND CHEMISTRY, 1993, 42 (4-6): : 581 - 584
  • [40] Surface dose measurements for intensity modulated radiation therapy
    Mitchell, M. J.
    Ramsey, C.
    MEDICAL PHYSICS, 2006, 33 (06) : 2249 - 2249