A simple method for approximate estimation of the displacement response of base-isolated structures

被引:5
|
作者
Yaghmaei-Sabegh, Saman [1 ]
Jafari, Ebrahim [1 ]
Neekmanesh, Shabnam [1 ]
机构
[1] Univ Tabriz, Dept Civil Engn, Tabriz, Iran
关键词
Maximum nonlinear roof displacement; Seismic base-isolated structures; Near-field ground motion record; Nonlinear time history analysis; Equivalent SDOF system; REINFORCED-CONCRETE BUILDINGS; NONLINEAR RESPONSE; ISOLATION SYSTEMS; PERFORMANCE; DRIFT; EARTHQUAKES; MODEL;
D O I
10.1016/j.istruc.2022.05.112
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The present study is a new attempt to provide a simple method for approximate estimation of the displacement response of base-isolated structures. For this purpose, first the accuracy of the existing methods which have been presented for base-isolated buildings is examined by comparison their estimations with the results of time history analyses of the 2, 4, 6, 8, 10 and 12 stories base-isolated models under 40 near-field and 40 far-field ground motion records. Then, a new method is proposed which is based on equivalent linear SDOF system with considering modified values of optimum damping ratio and effective period factor for base-isolated structures. The optimum damping ratio for base-isolated structures is obtained 31% and 23% for far- and near-field ground motion records, respectively. An effective period factor of 2.02 and 1.99 is extracted as a suitable value for obtaining the period of equivalent linear structure subjected to far- and near-field ground motion records, respectively. Results show that the proposed method not only has practically more simple procedure than the others, but also can provide reasonable estimates of the maximum nonlinear roof displacement of base-isolated structures subjected to an individual ground motion record. It's worth mentioning that most of the equivalent linearization methods presented in the past use displacement ductility ratio as a key parameter for estimating the nonlinear displacement of base-isolated structures while the proposed method doesn't need to such a parameter which cannot be easily predicted without performing nonlinear time history analysis. Therefore, as another attempt in this study, suitable approximate values of ductility ratio and other important coefficients are recommended for a number of existing approximate methods to improve their estimations for base-isolated structures.
引用
收藏
页码:1570 / 1583
页数:14
相关论文
共 50 条
  • [21] A combined control strategy using tuned liquid dampers to reduce displacement demands of base-isolated structures: a probabilistic approach
    Shoaei, Parham
    Oromi, Houtan Tahmasebi
    FRONTIERS OF STRUCTURAL AND CIVIL ENGINEERING, 2019, 13 (04) : 890 - 903
  • [22] Response Reduction of Secondary Piping Systems in Base-isolated Buildings
    Kamble, Vishal
    Bhaiya, Vishisht
    Bharti, Shiv Dayal
    Shrimali, Mahendra Kumar
    Datta, Tushar Kanti
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF CIVIL ENGINEERING, 2022, 46 (04) : 3319 - 3336
  • [23] Response Reduction of Secondary Piping Systems in Base-isolated Buildings
    Vishal Kamble
    Vishisht Bhaiya
    Shiv Dayal Bharti
    Mahendra Kumar Shrimali
    Tushar Kanti Datta
    Iranian Journal of Science and Technology, Transactions of Civil Engineering, 2022, 46 : 3319 - 3336
  • [24] Influence of ground motion duration and isolation bearings on the seismic response of base-isolated bridges
    Hassan, Afraa Labiba
    Billah, A. H. M. Muntasir
    ENGINEERING STRUCTURES, 2020, 222
  • [25] Seismic response variation of multistory base-isolated buildings applying lead rubber bearings
    Islam, A. B. M. Saiful
    Al-Kutti, Walid A.
    COMPUTERS AND CONCRETE, 2018, 21 (05) : 495 - 504
  • [26] Development and experimental evaluation of a passive gap damper device to prevent pounding in base-isolated structures
    Rawlinson, Taylor A.
    Marshall, Justin D.
    Ryan, Keri L.
    Zargar, Hamed
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2015, 44 (11) : 1661 - 1675
  • [27] A Resilience and Robustness Oriented Design of Base-Isolated Structures: The New Camerino University Research Center
    Dall'Asta, Andrea
    Leoni, Graziano
    Micozzi, Fabio
    Gioiella, Laura
    Ragni, Laura
    FRONTIERS IN BUILT ENVIRONMENT, 2020, 6
  • [28] A Hybrid Probability-Convex Model for the Seismic Demand Analysis of Bearing Displacement in the Benchmark Base-Isolated Structure
    Fan, Jian
    Zhang, Yanping
    ADVANCES IN STRUCTURAL ENGINEERING, 2014, 17 (07) : 1061 - 1073
  • [29] Analytical solution of seismic response of base-isolated structure with supplemental inerter
    Ye, Kun
    Shu, Shuai
    Hu, Liang
    Zhu, Hongping
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2019, 48 (09) : 1083 - 1090
  • [30] System identification of base-isolated building using seismic response data
    Furukawa, T
    Ito, M
    Izawa, K
    Noori, MN
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 2005, 131 (03): : 268 - 275