A simple method for approximate estimation of the displacement response of base-isolated structures

被引:5
作者
Yaghmaei-Sabegh, Saman [1 ]
Jafari, Ebrahim [1 ]
Neekmanesh, Shabnam [1 ]
机构
[1] Univ Tabriz, Dept Civil Engn, Tabriz, Iran
关键词
Maximum nonlinear roof displacement; Seismic base-isolated structures; Near-field ground motion record; Nonlinear time history analysis; Equivalent SDOF system; REINFORCED-CONCRETE BUILDINGS; NONLINEAR RESPONSE; ISOLATION SYSTEMS; PERFORMANCE; DRIFT; EARTHQUAKES; MODEL;
D O I
10.1016/j.istruc.2022.05.112
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The present study is a new attempt to provide a simple method for approximate estimation of the displacement response of base-isolated structures. For this purpose, first the accuracy of the existing methods which have been presented for base-isolated buildings is examined by comparison their estimations with the results of time history analyses of the 2, 4, 6, 8, 10 and 12 stories base-isolated models under 40 near-field and 40 far-field ground motion records. Then, a new method is proposed which is based on equivalent linear SDOF system with considering modified values of optimum damping ratio and effective period factor for base-isolated structures. The optimum damping ratio for base-isolated structures is obtained 31% and 23% for far- and near-field ground motion records, respectively. An effective period factor of 2.02 and 1.99 is extracted as a suitable value for obtaining the period of equivalent linear structure subjected to far- and near-field ground motion records, respectively. Results show that the proposed method not only has practically more simple procedure than the others, but also can provide reasonable estimates of the maximum nonlinear roof displacement of base-isolated structures subjected to an individual ground motion record. It's worth mentioning that most of the equivalent linearization methods presented in the past use displacement ductility ratio as a key parameter for estimating the nonlinear displacement of base-isolated structures while the proposed method doesn't need to such a parameter which cannot be easily predicted without performing nonlinear time history analysis. Therefore, as another attempt in this study, suitable approximate values of ductility ratio and other important coefficients are recommended for a number of existing approximate methods to improve their estimations for base-isolated structures.
引用
收藏
页码:1570 / 1583
页数:14
相关论文
共 45 条
[1]   Drift estimates in frame buildings subjected to near-fault ground motions [J].
Akkar, S ;
Yazgan, U ;
Gülkan, P .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2005, 131 (07) :1014-1024
[2]   A parametric study of linear and non-linear passively damped seismic isolation systems for buildings [J].
Alhan, C ;
Gavin, H .
ENGINEERING STRUCTURES, 2004, 26 (04) :485-497
[3]   Effects of the improper modeling of viscous damping on the first-mode and higher-mode dominated responses of base-isolated buildings [J].
Anajafi, Hamidreza ;
Medina, Ricardo A. ;
Santini-Bell, Erin .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2020, 49 (01) :51-73
[4]   Comparison of the seismic performance of a partial mass isolation technique with conventional TMD and base-isolation systems under broad-band and narrow-band excitations [J].
Anajafi, Hamidreza ;
Medina, Ricardo A. .
ENGINEERING STRUCTURES, 2018, 158 :110-123
[5]  
[Anonymous], 1986, UCBEERC8604
[6]  
[Anonymous], 2008, Building Code Requirements for Structural Concrete (ACI 318-08)
[7]  
[Anonymous], 2012, International Building Code
[8]  
[Anonymous], 2010, GUIDE DESIGNING INST, V523
[9]  
ASCE, 2010, Minimum Design Loads for Buildings and Other Structures, P7
[10]   Seismic response evaluation of base-isolated reinforced concrete buildings under bidirectional excitation [J].
Bhagat, Satish ;
Wijeyewickrema, Anil C. .
EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2017, 16 (02) :365-382