Prediction of source rock origin by chemometric analysis of Fourier transform infrared-attenuated total reflectance spectra of oil petroleum: Evaluation of aliphatic and aromatic fractions by self-modeling mixture analysis

被引:31
作者
Abbas, O
Dupuy, N
Rebufa, C [1 ]
Vrielynck, L
Kister, J
Permanyer, A
机构
[1] Dpt HSE, F-13708 La Ciotat, France
[2] Univ Aix Marseille 3, Lab GOAE, F-13397 Marseille 20, France
[3] Univ Barcelona, Dpt Goequim Petrol & Propeccio Geol, E-08028 Barcelona, Spain
关键词
spectroscopy; Fourier transform infrared spectroscopy; FT-IR; attenuated total reflectance; ATR; chemometrics; oils; principal component analysis; PCA; partial least squares; PLS; simple-to-use interactive self-modeling mixture analysis; SIMPLISMA;
D O I
10.1366/000370206776342508
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This study describes a new methodology for the interpretation of Fourier transform infrared (FT-IR) attenuated total reflectance (ATR) spectra of Algerian, Brazilian, and Venezuelan crude oils. It is based on a comparative study between a chemometric treatment and the classical one, which refers to indices calculation. In fact, the combined use of FT-IR indices and principal component analysis (PCA) has led to the classification of the studied samples in terms of geographic distribution. Quantitative analysis has been successfully realized by the supervised method partial least squares (PLS), which has permitted the prediction of the locations of oils. We have also applied another mathematical processing method, simple-to-use interactive self-modeling mixture analysis (SIMPLISMA), to evaluate the aromatic and aliphatic composition of the oils by extracting pure spectra representative of the different fractions.
引用
收藏
页码:304 / 314
页数:11
相关论文
共 26 条
[1]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[2]  
[Anonymous], 1990, GCSSEPM FDN 9 ANN RE
[3]   METROLOGICAL MEASUREMENT ACCURACY - DISCUSSION [J].
CURRIE, LA .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1991, 10 (1-2) :59-67
[4]  
DOUMENQ P, 1989, THESIS U AIX MARSEIL
[5]   Reliability of the contribution profiles obtained through the SIMPLISMA approach and used as reference in a calibration process - Application to Raman micro-analysis of dust particles [J].
Dupuy, N ;
Batonneau, Y .
ANALYTICA CHIMICA ACTA, 2003, 495 (1-2) :205-215
[6]  
FULLER M, 1988, ANAL CHEM, V50, P1906
[7]  
Gemperline P. J., 1989, J CHEMOMETR, V3, P549, DOI DOI 10.1002/cem.1180030404
[8]   PARTIAL LEAST-SQUARES METHODS FOR SPECTRAL ANALYSES .1. RELATION TO OTHER QUANTITATIVE CALIBRATION METHODS AND THE EXTRACTION OF QUALITATIVE INFORMATION [J].
HAALAND, DM ;
THOMAS, EV .
ANALYTICAL CHEMISTRY, 1988, 60 (11) :1193-1202
[9]  
HAMILTON AD, 1990, ADV SUPRAMOLECULAR C, V1, P1
[10]   DEGRADATION AND MATURITY CONTROLS ON OIL-FIELD PETROLEUM COLUMN HETEROGENEITY IN THE GULLFAKS FIELD, NORWEGIAN NORTH-SEA [J].
HORSTAD, I ;
LARTER, SR ;
DYPVIK, H ;
AAGAARD, P ;
BJORNVIK, AM ;
JOHANSEN, PE ;
ERIKSEN, S .
ORGANIC GEOCHEMISTRY, 1990, 16 (1-3) :497-510