X-ray fluoroscopy noise modeling for filter design

被引:36
|
作者
Cesarelli, M. [1 ]
Bifulco, P. [1 ]
Cerciello, T. [1 ]
Romano, M. [1 ]
Paura, L. [1 ]
机构
[1] Univ Naples Federico II, Dept Biomed Elect & Telecommun Engn, I-80125 Naples, Italy
关键词
Noise modeling; X-ray fluoroscopy; Poisson quantum noise; White compression; Skellam distribution; INTERVERTEBRAL KINEMATICS; IMAGES;
D O I
10.1007/s11548-012-0772-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Fluoroscopy is an invaluable tool in various medical practices such as catheterization or image-guided surgery. Patient's screen for prolonged time requires substantial reduction in X-ray exposure: The limited number of photons generates relevant quantum noise. Denoising is essential to enhance fluoroscopic image quality and can be considerably improved by considering the peculiar noise characteristics. This study presents analytical models of fluoroscopic noise to express the variance of noise as a function of gray level, a practical method to estimate the parameters of the models and a possible application to improve the performance of noise filtering. Quantum noise is modeled as a Poisson distribution and results strongly signal-dependent. However, fluoroscopic devices generally apply gray-level transformations (i.e., logarithmic-mapping, gamma-correction) for image enhancement. The resulting statistical transformations of the noise were analytically derived. In addition, a characterization of the statistics of noise for fluoroscopic image differences was offered by resorting to Skellam distribution. Real fluoroscopic sequences of a simple step-phantom were acquired by a conventional fluoroscopic device and were utilized as actual noise measurements to compare with. An adaptive spatio-temporal filter based on the local conditional average of similar pixels has been proposed. The gray-level differences between the local pixel and the neighboring pixels have been assumed as measure of similarity. Filter performance was evaluated by using real fluoroscopic images of a step phantom and acquired during a pacemaker implantation. The comparison between experimental data and the analytical derivation of the relationship between noise variance and mean pixel intensity (noise-parameter models) were presented relatively to raw-images, after applying logarithmic-mapping or gamma-correction and for difference images. Results have confirmed a great agreement (adjusted R-squared values > 0.8). Clipping effects of real sensors were also addressed. A fine image restoration has been obtained by using a conditioned spatio-temporal average filter based on the noise statistics previously estimated. Fluoroscopic noise modeling is useful to design effective procedures for noise estimation and image filtering. In particular, filter performance analysis has showed that the knowledge of the noise model and the accurate estimate of noise characteristics can significantly improve the image restoration, especially for edge preserving. Fluoroscopic image enhancement can support further X-ray exposure reduction, medical image analysis and automated object identification (i.e., surgery tools, anatomical structures).
引用
收藏
页码:269 / 278
页数:10
相关论文
共 50 条
  • [41] Rapid Image Registration of Three-Dimensional Transesophageal Echocardiography and X-ray Fluoroscopy for the Guidance of Cardiac Interventions
    Gao, Gang
    Penney, Graeme
    Gogin, Nicolas
    Cathier, Pascal
    Arujuna, Aruna
    Wright, Matt
    Caulfield, Dennis
    Rinaldi, Aldo
    Razavi, Reza
    Rhode, Kawal
    INFORMATION PROCESSING IN COMPUTER-ASSISTED INTERVENTIONS, 2010, 6135 : 124 - +
  • [42] Quantitative image quality evaluation of pixel-binning in a flat-panel detector for x-ray fluoroscopy
    Srinivas, Y
    Wilson, DL
    MEDICAL PHYSICS, 2004, 31 (01) : 131 - 141
  • [43] 3D kinematics of mobile-bearing total knee arthroplasty using X-ray fluoroscopy
    Yamazaki, Takaharu
    Futai, Kazuma
    Tomita, Tetsuya
    Sato, Yoshinobu
    Yoshikawa, Hideki
    Tamura, Shinichi
    Sugamoto, Kazuomi
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (04) : 487 - 495
  • [44] Method to calculate frequency characteristics of reconstruction filter kernel in X-ray computed tomography
    Sato, Kazuhiro
    Tomita, Yu
    Kageyama, Ryota
    Takane, Yumi
    Kayano, Shingo
    Saito, Haruo
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (01) : 69 - 78
  • [45] Dynamic coronary roadmapping via catheter tip tracking in X-ray fluoroscopy with deep learning based Bayesian filtering
    Ma, Hua
    Smal, Ihor
    Daemen, Joost
    van Walsum, Theo
    MEDICAL IMAGE ANALYSIS, 2020, 61
  • [46] In-situ observation on the magnesiothermic reduction of TiCl4 around 800 °C by microfocus X-ray fluoroscopy
    Kishimoto, Akihiro
    Uda, Tetsuya
    JOURNAL OF ALLOYS AND COMPOUNDS, 2021, 874
  • [47] X-ray fluorescence holography
    Hayashi, Kouichi
    Happo, Naohisa
    Hosokawa, Shinya
    Hu, Wen
    Matsushita, Tomohiro
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2012, 24 (09)
  • [48] Applications of X-Ray Holography
    Shi, Bingjun
    Fu, Yuan
    Yang, Yan
    INTERNATIONAL JOURNAL OF OPTICS, 2021, 2021 (2021)
  • [49] Quantitative image quality evaluation of an order-statistic filter in x-ray fluoroscopic imaging
    Wilson, DL
    Srinivas, Y
    Sanchez-Marin, FJ
    Jabri, KN
    MEDICAL IMAGING 2000: IMAGE PERCEPTION AND PERFORMANCE, 2000, 3981 : 43 - 48
  • [50] Novel real-time tumor-contouring method using deep learning to prevent mistracking in X-ray fluoroscopy
    Terunuma T.
    Tokui A.
    Sakae T.
    Radiological Physics and Technology, 2018, 11 (1) : 43 - 53