X-ray fluoroscopy noise modeling for filter design

被引:36
|
作者
Cesarelli, M. [1 ]
Bifulco, P. [1 ]
Cerciello, T. [1 ]
Romano, M. [1 ]
Paura, L. [1 ]
机构
[1] Univ Naples Federico II, Dept Biomed Elect & Telecommun Engn, I-80125 Naples, Italy
关键词
Noise modeling; X-ray fluoroscopy; Poisson quantum noise; White compression; Skellam distribution; INTERVERTEBRAL KINEMATICS; IMAGES;
D O I
10.1007/s11548-012-0772-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Fluoroscopy is an invaluable tool in various medical practices such as catheterization or image-guided surgery. Patient's screen for prolonged time requires substantial reduction in X-ray exposure: The limited number of photons generates relevant quantum noise. Denoising is essential to enhance fluoroscopic image quality and can be considerably improved by considering the peculiar noise characteristics. This study presents analytical models of fluoroscopic noise to express the variance of noise as a function of gray level, a practical method to estimate the parameters of the models and a possible application to improve the performance of noise filtering. Quantum noise is modeled as a Poisson distribution and results strongly signal-dependent. However, fluoroscopic devices generally apply gray-level transformations (i.e., logarithmic-mapping, gamma-correction) for image enhancement. The resulting statistical transformations of the noise were analytically derived. In addition, a characterization of the statistics of noise for fluoroscopic image differences was offered by resorting to Skellam distribution. Real fluoroscopic sequences of a simple step-phantom were acquired by a conventional fluoroscopic device and were utilized as actual noise measurements to compare with. An adaptive spatio-temporal filter based on the local conditional average of similar pixels has been proposed. The gray-level differences between the local pixel and the neighboring pixels have been assumed as measure of similarity. Filter performance was evaluated by using real fluoroscopic images of a step phantom and acquired during a pacemaker implantation. The comparison between experimental data and the analytical derivation of the relationship between noise variance and mean pixel intensity (noise-parameter models) were presented relatively to raw-images, after applying logarithmic-mapping or gamma-correction and for difference images. Results have confirmed a great agreement (adjusted R-squared values > 0.8). Clipping effects of real sensors were also addressed. A fine image restoration has been obtained by using a conditioned spatio-temporal average filter based on the noise statistics previously estimated. Fluoroscopic noise modeling is useful to design effective procedures for noise estimation and image filtering. In particular, filter performance analysis has showed that the knowledge of the noise model and the accurate estimate of noise characteristics can significantly improve the image restoration, especially for edge preserving. Fluoroscopic image enhancement can support further X-ray exposure reduction, medical image analysis and automated object identification (i.e., surgery tools, anatomical structures).
引用
收藏
页码:269 / 278
页数:10
相关论文
共 50 条
  • [31] Virtual bronchoscopic navigation without X-ray fluoroscopy to diagnose peripheral pulmonary lesions: a randomized trial
    Asano, Fumihiro
    Ishida, Takashi
    Shinagawa, Naofumi
    Sukoh, Noriaki
    Anzai, Masaki
    Kanazawa, Kenya
    Tsuzuku, Akifumi
    Morita, Satoshi
    BMC PULMONARY MEDICINE, 2017, 17
  • [32] Virtual bronchoscopic navigation without X-ray fluoroscopy to diagnose peripheral pulmonary lesions: a randomized trial
    Fumihiro Asano
    Takashi Ishida
    Naofumi Shinagawa
    Noriaki Sukoh
    Masaki Anzai
    Kenya Kanazawa
    Akifumi Tsuzuku
    Satoshi Morita
    BMC Pulmonary Medicine, 17
  • [33] First experimental results of gated proton imaging using x-ray fluoroscopy to detect a fiducial marker
    Tanaka, Sodai
    Miyamoto, Naoki
    Matsuo, Yuto
    Yoshimura, Takaaki
    Takao, Seishin
    Matsuura, Taeko
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (18)
  • [34] Hydrodynamics in a gas-solids fluidized bed using X-ray fluoroscopy and pressure fluctuation measurements
    Wu, Bangyou
    He, Zhengxing
    Kantzas, Apostolos
    Bellehumeur, Celine T.
    Kryuchkov, Sergey
    MACROMOLECULAR SYMPOSIA, 2006, 243 : 35 - 45
  • [35] UK X-ray Research and the Spacelab 2 X-ray Telescope
    Millard, Douglas J.
    HISTORY OF ROCKETRY AND ASTRONAUTICS, 2014, 41 : 323 - 333
  • [36] Efficient Feature-based 2D/3D Registration of Transesophageal Echocardiography to X-ray Fluoroscopy for Cardiac Interventions
    Hatt, Charles R.
    Speidel, Michael A.
    Raval, amish N.
    MEDICAL IMAGING 2014: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2014, 9036
  • [37] Perception of detail and greyscale range in X-ray fluoroscopy images captured with a personal computer and frame-grabber
    Okkalides, D
    EUROPEAN JOURNAL OF RADIOLOGY, 1996, 23 (02) : 149 - 158
  • [38] Monte Carlo simulation of inverse geometry x-ray fluoroscopy using a modified MC-GPU framework
    Dunkerley, David A. P.
    Tomkowiak, Michael T.
    Slagowski, Jordan M.
    McCabe, Bradley P.
    Funk, Tobias
    Speidel, Michael A.
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [39] Directional vector-based quick evaluation method for protective plate effects in X-ray fluoroscopy (DQPEX)
    Hizukuri, Kyoko
    Fujibuchi, Toshioh
    Han, Donghee
    Arakawa, Hiroyuki
    Furuta, Takuya
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2025, 18 (01) : 196 - 208
  • [40] Pyramid attention recurrent networks for real-time guidewire segmentation and tracking in intraoperative X-ray fluoroscopy
    Zhou, Yan-Jie
    Xie, Xiao-Liang
    Zhou, Xiao-Hu
    Liu, Shi-Qi
    Bian, Gui-Bin
    Hou, Zeng-Guang
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2020, 83