X-ray fluoroscopy noise modeling for filter design

被引:36
|
作者
Cesarelli, M. [1 ]
Bifulco, P. [1 ]
Cerciello, T. [1 ]
Romano, M. [1 ]
Paura, L. [1 ]
机构
[1] Univ Naples Federico II, Dept Biomed Elect & Telecommun Engn, I-80125 Naples, Italy
关键词
Noise modeling; X-ray fluoroscopy; Poisson quantum noise; White compression; Skellam distribution; INTERVERTEBRAL KINEMATICS; IMAGES;
D O I
10.1007/s11548-012-0772-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Fluoroscopy is an invaluable tool in various medical practices such as catheterization or image-guided surgery. Patient's screen for prolonged time requires substantial reduction in X-ray exposure: The limited number of photons generates relevant quantum noise. Denoising is essential to enhance fluoroscopic image quality and can be considerably improved by considering the peculiar noise characteristics. This study presents analytical models of fluoroscopic noise to express the variance of noise as a function of gray level, a practical method to estimate the parameters of the models and a possible application to improve the performance of noise filtering. Quantum noise is modeled as a Poisson distribution and results strongly signal-dependent. However, fluoroscopic devices generally apply gray-level transformations (i.e., logarithmic-mapping, gamma-correction) for image enhancement. The resulting statistical transformations of the noise were analytically derived. In addition, a characterization of the statistics of noise for fluoroscopic image differences was offered by resorting to Skellam distribution. Real fluoroscopic sequences of a simple step-phantom were acquired by a conventional fluoroscopic device and were utilized as actual noise measurements to compare with. An adaptive spatio-temporal filter based on the local conditional average of similar pixels has been proposed. The gray-level differences between the local pixel and the neighboring pixels have been assumed as measure of similarity. Filter performance was evaluated by using real fluoroscopic images of a step phantom and acquired during a pacemaker implantation. The comparison between experimental data and the analytical derivation of the relationship between noise variance and mean pixel intensity (noise-parameter models) were presented relatively to raw-images, after applying logarithmic-mapping or gamma-correction and for difference images. Results have confirmed a great agreement (adjusted R-squared values > 0.8). Clipping effects of real sensors were also addressed. A fine image restoration has been obtained by using a conditioned spatio-temporal average filter based on the noise statistics previously estimated. Fluoroscopic noise modeling is useful to design effective procedures for noise estimation and image filtering. In particular, filter performance analysis has showed that the knowledge of the noise model and the accurate estimate of noise characteristics can significantly improve the image restoration, especially for edge preserving. Fluoroscopic image enhancement can support further X-ray exposure reduction, medical image analysis and automated object identification (i.e., surgery tools, anatomical structures).
引用
收藏
页码:269 / 278
页数:10
相关论文
共 50 条
  • [1] X-ray fluoroscopy noise modeling for filter design
    M. Cesarelli
    P. Bifulco
    T. Cerciello
    M. Romano
    L. Paura
    International Journal of Computer Assisted Radiology and Surgery, 2013, 8 : 269 - 278
  • [2] Effects of motion blurring in x-ray fluoroscopy
    Xue, P
    Wilson, DL
    MEDICAL PHYSICS, 1998, 25 (05) : 587 - 599
  • [3] Perception of temporally filtered X-ray fluoroscopy images
    Wilson, DL
    Jabri, KN
    Aufrichtig, R
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (01) : 22 - 31
  • [4] Role of smooth pursuit eye-movements on the detection of moving objects in x-ray fluoroscopy noise
    Wilson, DL
    Manjeshwar, RM
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 792 - 794
  • [5] Optimization of detector pixel size for interventional x-ray fluoroscopy
    Manjeshwar, RM
    Wilson, DL
    MEDICAL IMAGING 2001: IMAGE PERCEPTION AND PERFORMANCE, 2001, 4324 : 23 - 34
  • [6] Quantitative image quality of spatially filtered x-ray fluoroscopy
    Jabri, KN
    Wilson, DL
    MEDICAL IMAGING 1999: IMAGE PERCEPTION AND PERFORMANCE, 1999, 3663 : 296 - 303
  • [7] Moving segments region of interest attenuator for x-ray fluoroscopy
    Sassi, SA
    Britten, AJ
    MEDICAL PHYSICS, 1999, 26 (01) : 19 - 26
  • [8] Noise simulation in x-ray CT
    Massoumzadeh, P
    Earl, OA
    Whiting, BR
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 898 - 909
  • [9] A Comparison of Denoising Algorithms for Effective Edge Detection in X-Ray Fluoroscopy
    Andreozzi, Emilio
    Pirozzi, Maria Agnese
    Sarno, Antonio
    Esposito, Daniele
    Cesarelli, Mario
    Bifulco, Paolo
    XV MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING - MEDICON 2019, 2020, 76 : 405 - 413
  • [10] Comparison of analog and digital magnification in x-ray fluoroscopy image sequences
    Srinivas, Y
    Wilson, DL
    MEDICAL IMAGING 2002: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2002, 4686 : 129 - 138