A Thermal Monitoring Sheet With Low Influence From Adjacent Waterbolus for Tissue Surface Thermometry During Clinical Hyperthermia

被引:10
|
作者
Arunachalam, Kavitha [1 ]
Maccarini, Paolo F. [1 ]
Stauffer, Paul R. [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Hyperthermia Phys Div, Durham, NC 27713 USA
关键词
Heat transfer; hyperthermia; noninvasive thermometry; surface thermal modeling; temperature distribution measurement; thermal monitoring sheet;
D O I
10.1109/TBME.2008.925693
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a complete thermal analysis of a novel conformal surface thermometer design with directional sensitivity for real-time temperature monitoring during hyperthermia treatments of large superficial cancer. The thermal monitoring sheet (TMS) discussed in this paper consists of a 2-D array of fiberoptic sensors embedded between two layers of flexible, low-loss, and thermally conductive printed circuit board (PCB) film. Heat transfer across all interfaces from the tissue surface through multiple layers of insulating dielectrics surrounding the small buried temperature sensor and into an adjacent temperature-regulated water coupling bolus was studied using 3-D thermal simulation software. Theoretical analyses were carried out to identify the most effective differential TMS probe configuration possible with commercially available flexible PCB materials and to compare their thermal responses with omnidirectional probes commonly used in clinical hyperthermia. A TMS sensor design that employ's 0.0508-mm Kapton MTB and 0.2032-mm Kapton HN flexible polyimide films is proposed for tissue surface thermometry, with low influence from the adjacent waterbolus. Comparison of the thermal simulations with clinical probes indicates the new differential TMS probe design to outperform in terms of both transient response and steady-state accuracy in selectively reading the tissue surface temperature, while decreasing the overall thermal barrier of the probe between the coupling waterbolus and tissue surface.
引用
收藏
页码:2397 / 2406
页数:10
相关论文
共 4 条
  • [1] Performance evaluation of a conformal thermal monitoring sheet sensor array for measurement of surface temperature distributions during superficial hyperthermia treatments
    Arunachalam, K.
    Maccarini, P.
    Juang, T.
    Gaeta, C.
    Stauffer, P. R.
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2008, 24 (04) : 313 - 325
  • [2] Clinical Feasibility of a High-Resolution Thermal Monitoring Sheet for Superficial Hyperthermia in Breast Cancer Patients
    Bakker, Akke
    Zweije, Remko
    Kok, Henny Petra
    Kolff, Merel Willemijn
    van den Bongard, H. J. G. Desiree
    Schmidt, Manfred
    van Tienhoven, Geertjan
    Crezee, Hans
    CANCERS, 2020, 12 (12) : 1 - 18
  • [3] Influence of thermal relaxation time on thermomechanical interactions in biological tissue during hyperthermia treatment
    Hobiny, A.
    Abbas, I.
    JOURNAL OF THERMAL BIOLOGY, 2023, 118
  • [4] TISSUE-LIGHT INTERACTION DURING MONITORING OF THERMAL LESION USING QUANTUM DOT MEDIATED FLUORESCENCE THERMOMETRY
    Hanson, Willard
    Abdollahzadeh, Najma
    Han, Bumsoo
    PROCEEDINGS OF THE ASME/JSME 8TH THERMAL ENGINEERING JOINT CONFERENCE 2011, VOL 1 PTS A AND B, 2011, : 1 - +