Study on the polyfurfural film modified glassy carbon electrode and its application in polyphenols determination

被引:34
|
作者
Fu, Yanhui [1 ,2 ]
Lin, Yongping [3 ]
Chen, Tiansheng [3 ]
Wang, Lishi [1 ,2 ]
机构
[1] S China Univ Technol, Sch Chem & Chem Engn, Guangzhou 510640, Peoples R China
[2] S China Univ Technol, State Key Lab Pulp & Paper Engn, Guangzhou 510640, Peoples R China
[3] Guangdong Power Grid Corp, Elect Power Res Inst, Guangzhou 510000, Guangdong, Peoples R China
关键词
Polyfurfural film; Dihydroxybenzenes; Resveratrol; Quercetin; Simultaneous determination; PERFORMANCE LIQUID-CHROMATOGRAPHY; DIHYDROXYBENZENE ISOMERS; TRANS-RESVERATROL; ELECTROCHEMICAL-BEHAVIOR; RED WINES; QUERCETIN; HYDROQUINONE; NANOTUBES; RESORCINOL; CATECHOL;
D O I
10.1016/j.jelechem.2012.09.040
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A polyfurfural film modified glassy carbon electrode was prepared by electrochemical polymerization of furfural in acetonitrile solutions and the electrode exhibited a good electrocatalytic activity on the oxidation of polyphenols in 0.1 mol L-1 phosphate buffer solution (pH 6.0). Applications of the polyfurfural film electrode for simultaneous determination of hydroquinone (HQ), catechol (CC) and resorcinol (RS), and for simultaneous determination of resveratrol (RT) and quercetin (QC) were demonstrated. The linear relationship for HQ CC and RS were obtained in the range of 0.5-10, 1-40 and 0.5-10 mu mol L-1, respectively. The detection limits (S/N = 3) were 0.04 mu mol L-1, 0.08 mu mol L-1 and 0.06 mu mol L-1, respectively. While for RT and QC, the oxidation peak current of RT was linear with the concentration of RT from 0.8 to 8 mu mol L-1 and the detection limit (S/N = 3) was 0.4 mu mol L-1. Meanwhile the oxidation peak current of QC was linear with the concentration of QC from 0.8 to 12 mu mol L-1 and the detection limit (S/N = 3) was 0.3 mu mol L-1. Simultaneous determination of relevant polyphenols without interference with each other was realized by the polyfurfural film modified electrode. The electrodes are expected to be used as sensors for the three dihydroxybenzene isomers. The electrode also has the potential application of rapid determination of RT and QC in wine and food. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:25 / 29
页数:5
相关论文
共 50 条
  • [1] Simultaneous electrochemical determination of nitrophenol isomers with the polyfurfural film modified glassy carbon electrode
    Wei, Tianyan
    Huang, Xinjian
    Zeng, Qiang
    Wang, Lishi
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 743 : 105 - 111
  • [2] Polyfurfural film modified glassy carbon electrode for highly sensitive nifedipine determination
    Zeng, Qiang
    Wei, Tianyan
    Wang, Min
    Huang, Xinjian
    Fang, Yishan
    Wang, Lishi
    ELECTROCHIMICA ACTA, 2015, 186 : 465 - 470
  • [3] High sensitivity simultaneous determination of myricetin and rutin using a polyfurfural film modified glassy carbon electrode
    Huang, Jianzhi
    Shen, Xiaolei
    Hu, Qiong
    Ma, Ya
    Bai, Silan
    Yue, Guoqing
    Yu, Xiongtao
    Zeng, Qiang
    Wang, Lishi
    RSC ADVANCES, 2016, 6 (98): : 95435 - 95441
  • [4] Simultaneous Determination of Hydroquinone, Catechol and Resorcinol Based on Graphene/Cobalt Hexacyanoferrate Modified Glassy Carbon Electrode
    Huang Kejing
    Yu Sheng
    Wang Lan
    Gan Tian
    Li Mei
    ACTA CHIMICA SINICA, 2012, 70 (06) : 735 - 740
  • [5] Simultaneous voltammetric determination of dihydroxybenzene isomers at single-walled carbon nanohorn modified glassy carbon electrode
    Zhu, Shuyun
    Gao, Wenyue
    Zhang, Ling
    Zhao, Jianming
    Xu, Guobao
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 198 : 388 - 394
  • [6] Phospholipid Modified Glassy Carbon Electrode and its Application for Determination of Pesticides
    Svecova, Hana
    Sokolova, Romana
    Souckova, Jitka
    Skopalova, Jana
    Bartak, Petr
    XXXVI MODERNI ELEKTROCHEMICKE METODY, 2016, : 252 - 255
  • [7] Electrochemical behavior of catechol, resorcinol and hydroquinone at graphene-chitosan composite film modified glassy carbon electrode and their simultaneous determination in water samples
    Yin, Huanshun
    Zhang, Qingming
    Zhou, Yunlei
    Ma, Qiang
    Liu, Tao
    Zhu, Lusheng
    Ai, Shiyun
    ELECTROCHIMICA ACTA, 2011, 56 (06) : 2748 - 2753
  • [8] Polyfurfural-Electrochemically Reduced Graphene Oxide Modified Glassy Carbon Electrode for the Direct Determination of Nitrofurazone
    Ye, Fang
    Huang, Jianzhi
    Xu, Yongqun
    Zeng, Qiang
    Nan, Junmin
    Wang, Lishi
    ANALYTICAL LETTERS, 2018, 51 (05) : 728 - 741
  • [9] Simultaneous Determination of Hydroquinone and Catechol at an Activated Glassy Carbon Electrode
    Ahammad, A. J. Saleh
    Sarker, Subrata
    Rahman, Md Aminur
    Lee, Jae-Joon
    ELECTROANALYSIS, 2010, 22 (06) : 694 - 700
  • [10] A voltammetric sensor based on eosin Y film modified glassy carbon electrode for simultaneous determination of hydroquinone and catechol
    He, Jiahong
    Qiu, Ri
    Li, Wenpo
    Xing, Shaohua
    Song, Zhongrong
    Li, Qiang
    Zhang, Shengtao
    ANALYTICAL METHODS, 2014, 6 (16) : 6494 - 6503