Strength of slender concrete-filled steel box columns incorporating local buckling

被引:46
|
作者
Vrcelj, Z [1 ]
Uy, B [1 ]
机构
[1] Univ New S Wales, Sch Civil Environm Engn, Sydney, NSW 2052, Australia
基金
澳大利亚研究理事会;
关键词
conerete-filled steel box columns; local buckling; reduction factor; Eurocode; 4;
D O I
10.1016/S0143-974X(01)00045-1
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Composite columns have seen a significant resurgence in their use over the last decade. This has resulted in the use of very thin-walled steel sections, which are susceptible to local buckling. Furthermore, these members have been applied in jump-start construction in the basement of tall buildings where slenderness effects may be dominant. The interaction between local and global buckling therefore needs to be investigated. This paper presents a method for incorporating local buckling in assessing the global buckling load of concrete filled steel columns. A parametric study is then undertaken to consider the effects of column slenderness, plate slenderness, steel yield strength and concrete compressive strength on the behaviour. The overall buckling loads of these columns are then compared with the buckling loads when local buckling is neglected. A series of design charts are then established to determine the reduction factor for global buckling caused by local buckling of the steel section. This reduction factor is then shown to be useful in augmenting existing international specifications such as Eurocode (C) 2002 Published by Elsevier Science Ltd.
引用
收藏
页码:275 / 300
页数:26
相关论文
共 50 条
  • [21] Buckling of Slender Concrete-Filled Steel Tubes with Compliant Interfaces
    Schnabl, Simon
    Planinc, Igor
    LATIN AMERICAN JOURNAL OF SOLIDS AND STRUCTURES, 2017, 14 (10): : 1837 - 1852
  • [22] STRENGTH ANALYSIS OF CONCRETE-FILLED THIN-WALLED STEEL BOX COLUMNS
    GE, HB
    USAMI, T
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1994, 30 (03) : 259 - 281
  • [23] Local and post-local buckling of concrete filled steel welded box columns
    Uy, B
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1998, 47 (1-2) : 47 - 72
  • [24] STRENGTH OF CONCRETE-FILLED THIN-WALLED STEEL BOX COLUMNS - EXPERIMENT
    GE, HB
    USAMI, T
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1992, 118 (11): : 3036 - 3054
  • [25] Cyclic tests of concrete-filled steel box columns
    Ge, H
    Usami, T
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1996, 122 (10): : 1169 - 1177
  • [26] Influence of ultra-high strength infill in slender concrete-filled steel tubular columns
    Portoles, J. M.
    Serra, E.
    Romero, M. L.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2013, 86 : 107 - 114
  • [27] Effects of long-term loads on the strength of concrete-filled steel box columns
    Han, L.H.
    Tao, Z.
    Liu, W.
    Chen, B.C.
    Zhongguo Gonglu Xuebao/China Journal of Highway and Transport, 2001, 14 (03):
  • [28] Creep Buckling Analysis of Concrete-Filled Steel Tubular Columns
    Zhao R.
    Wu D.
    Wang Y.
    Jia Y.
    Liao P.
    Xinan Jiaotong Daxue Xuebao/Journal of Southwest Jiaotong University, 2019, 54 (03): : 468 - 474
  • [29] Nonlinear analysis of square concrete-filled double steel tubular slender columns incorporating preload effects
    Ahmed, Mizan
    Liang, Qing Quan
    Patel, Vipulkumar Ishvarbhai
    Hadi, Muhammad N. S.
    ENGINEERING STRUCTURES, 2020, 207
  • [30] Ductility, strength and stability of concrete-filled fabricated steel box columns for tall buildings
    Uy, B
    STRUCTURAL DESIGN OF TALL BUILDINGS, 1998, 7 (02): : 113 - 133