A 100 m laser strainmeter system in the Kamioka mine, Japan, for precise observations of tidal strains

被引:19
|
作者
Takemoto, S [1 ]
Momose, H
Araya, A
Morii, W
Akamatsu, J
Ohashi, M
Takamori, A
Miyoki, S
Uchiyama, T
Tatsumi, D
Higashi, T
Telada, S
Fukuda, Y
机构
[1] Kyoto Univ, Grad Sch Sci, Kyoto 6068502, Japan
[2] Univ Tokyo, Earthquake Res Inst, Tokyo 1130032, Japan
[3] Kyoto Univ, Disaster Prevent Res Inst, Uji 6110011, Japan
[4] Univ Tokyo, Inst Cosm Ray Res, Kashiwa, Chiba 2778582, Japan
[5] Natl Astron Observ, Mitaka, Tokyo 1818588, Japan
[6] Natl Inst Adv Ind Sci & Technol, Tsukuba, Ibaraki 3058568, Japan
基金
日本学术振兴会;
关键词
Kamioka; laser strainmeter; tidal strain; topographic effect; FEM;
D O I
10.1016/j.jog.2005.08.009
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
A 100 m laser strainmeter system was installed in a deep tunnel about 1000 m below the ground surface in Kamioka, Gifu, Japan in 2003. The system consists of three types of independent interferometers: (1) an EW linear strainmeter of the Michelson type with unequal arms, (2) an NS-EW differential strainmeter of the Michelson type with equal arms and (3) an NS absolute strainmeter of the Fabry-Perot type. These are configured in L-shaped vacuum pipes, each of which has a length of 100 m. (1) and (2) are highly sensitive (order of 10(-13) strain) and have wide dynamical range (10(-13) to 10(-6)). Based on data obtained from these strainmeters (1) and (2) during the period of about 4 months in 2003, we analyzed tidal strains by employing the tidal analysis program BAYTAP-G. Observed tidal strain amplitudes of eight major constituents were compared with theoretically expected ones that were obtained from the GOTIC2 program. As a result, it was revealed that the "observed" amplitudes are about 10-20% smaller than the "expected" amplitudes. In order to explain these discrepancies, we examined the topographic effect using three-dimensional finite element model (3D FEM), and succeeded in reducing the discrepancies within several percent. This result shows that our laser strainmeter system in Kamioka has sufficient reliability to detect small strain changes of the order of 10(-10) in the tidal frequency band. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:23 / 29
页数:7
相关论文
共 5 条
  • [1] Design and operation of a 1500-m laser strainmeter installed at an underground site in Kamioka, Japan
    Araya, Akito
    Takamori, Akiteru
    Morii, Wataru
    Miyo, Kouseki
    Ohashi, Masatake
    Hayama, Kazuhiro
    Uchiyama, Takashi
    Miyoki, Shinji
    Saito, Yoshio
    EARTH PLANETS AND SPACE, 2017, 69
  • [2] Design and operation of a 1500-m laser strainmeter installed at an underground site in Kamioka, Japan
    Akito Araya
    Akiteru Takamori
    Wataru Morii
    Kouseki Miyo
    Masatake Ohashi
    Kazuhiro Hayama
    Takashi Uchiyama
    Shinji Miyoki
    Yoshio Saito
    Earth, Planets and Space, 69
  • [3] Ground strains induced by the 2022 Hunga-Tonga volcanic eruption, observed by a 1500-m laser strainmeter at Kamioka, Japan
    Akiteru Takamori
    Akito Araya
    Kouseki Miyo
    Tatsuki Washimi
    Takaaki Yokozawa
    Hideaki Hayakawa
    Masatake Ohashi
    Earth, Planets and Space, 75
  • [4] Ground strains induced by the 2022 Hunga-Tonga volcanic eruption, observed by a 1500-m laser strainmeter at Kamioka, Japan
    Takamori, Akiteru
    Araya, Akito
    Miyo, Kouseki
    Washimi, Tatsuki
    Yokozawa, Takaaki
    Hayakawa, Hideaki
    Ohashi, Masatake
    EARTH PLANETS AND SPACE, 2023, 75 (01):
  • [5] A 50-m laser strainmeter system installed in Transbaikalia: testing results
    Dolgikh, G. I.
    Dolgikh, S. G.
    Rasskazov, I. Yu.
    Lugovoy, V. A.
    Saksin, B. G.