Detection of neutrons and γ rays by a xenon pulsed ionization chamber

被引:5
|
作者
Dmitrenko, V. V. [1 ]
Vlasik, K. F. [1 ]
Grachev, V. M. [1 ]
Dukhvalov, A. G. [1 ]
Ulin, S. E. [1 ]
Uteshev, Z. M. [1 ]
Shustov, A. E. [1 ]
机构
[1] Natl Res Nucl Univ, Moscow Engn Phys Inst MEPhI, Moscow 115409, Russia
关键词
Xenon; Thermal Neutron; Neutron Capture; Radiative Capture; Sensitive Volume;
D O I
10.1134/S0020441212030104
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The applicability of a xenon gamma-ray spectrometer based on a high-pressure (50 atm) xenon cylindrical ionization chamber to thermal neutron detection is discussed. The reaction of radiative capture of thermal neutron capture Xe-131(n, gamma)Xe-132* followed by emission of 668-keV gamma rays detectable by the spectrometer is used. The response of the xenon spectrometer with a sensitive volume of 0.2 L is analyzed. The measured thermal neutron detection efficiency is 0.08%. The advantage of the detector is its capability of simultaneously detecting both thermal neutrons and gamma rays, which allows precise and high-efficiency identification of radioactive and fissile materials.
引用
收藏
页码:419 / 422
页数:4
相关论文
共 50 条
  • [41] Observation of anticorrelation between scintillation and ionization for MeV gamma rays in liquid xenon
    Aprile, E.
    Giboni, K. L.
    Majewski, P.
    Ni, K.
    Yamashita, M.
    PHYSICAL REVIEW B, 2007, 76 (01):
  • [42] COLLECTION EFFICIENCY OF AN IONIZATION-CHAMBER IN A PULSED SWEPT BEAM - CHAMBER SIZE EFFECTS
    MELI, JA
    WEINHOUS, MS
    PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (10): : 1139 - 1146
  • [43] Performance of a high-pressure xenon ionization chamber for environmental radiation monitoring
    Kim, H. S.
    Park, S. H.
    Ha, J. H.
    Kim, Y. K.
    Kim, J. K.
    Cho, S. Y.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 659 - 663
  • [44] α-particle spectrometer based on xenon gas ionization chamber using coplanar electrodes
    Hasebe, N.
    Miyajima, M.
    Shibamura, E.
    Hitachi, A.
    Naito, M.
    Murakami, K.
    Kusano, H.
    Matias-Lopes, J. A.
    Dmitrenko, V. V.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 925 : 123 - 127
  • [45] Dual-anode high-pressure xenon cylindrical ionization chamber
    Bolotnikov, A
    Bolozdynya, A
    DeVito, R
    Richards, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) : 1262 - 1269
  • [46] DESIGN, CONSTRUCTION AND PERFORMANCE OF A LIQUID XENON AND LIQUID ARGON IONIZATION-CHAMBER
    IMEL, DA
    THOMAS, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (01): : 291 - 298
  • [47] Cylindrical ionization chamber with a screening grid and xenon under the pressure of 50 atm
    Moskovskij Inzhenerno-Fizicheskij, Inst, Moscow, Russia
    Prib Tekh Eksp, 3 (61-68):
  • [48] A PHOTO-IONIZATION DETECTOR FOR THE DETECTION OF XENON LIGHT
    ANDERSON, DF
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (01) : 842 - 848
  • [49] Dosimetry of pulsed clinical proton beams by a small ionization chamber
    Nohtomi, A
    Sakae, T
    Tsunashima, Y
    Kohno, R
    MEDICAL PHYSICS, 2001, 28 (07) : 1431 - 1435
  • [50] Detection of thermal neutrons in cylindrical ionization chamber filled with high-pressure Xe+3Hegas mixture
    Bolozdynya, A
    Bolotnikov, A
    Richards, J
    Proctor, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 522 (03): : 595 - 597