Detection of neutrons and γ rays by a xenon pulsed ionization chamber

被引:5
|
作者
Dmitrenko, V. V. [1 ]
Vlasik, K. F. [1 ]
Grachev, V. M. [1 ]
Dukhvalov, A. G. [1 ]
Ulin, S. E. [1 ]
Uteshev, Z. M. [1 ]
Shustov, A. E. [1 ]
机构
[1] Natl Res Nucl Univ, Moscow Engn Phys Inst MEPhI, Moscow 115409, Russia
关键词
Xenon; Thermal Neutron; Neutron Capture; Radiative Capture; Sensitive Volume;
D O I
10.1134/S0020441212030104
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The applicability of a xenon gamma-ray spectrometer based on a high-pressure (50 atm) xenon cylindrical ionization chamber to thermal neutron detection is discussed. The reaction of radiative capture of thermal neutron capture Xe-131(n, gamma)Xe-132* followed by emission of 668-keV gamma rays detectable by the spectrometer is used. The response of the xenon spectrometer with a sensitive volume of 0.2 L is analyzed. The measured thermal neutron detection efficiency is 0.08%. The advantage of the detector is its capability of simultaneously detecting both thermal neutrons and gamma rays, which allows precise and high-efficiency identification of radioactive and fissile materials.
引用
收藏
页码:419 / 422
页数:4
相关论文
共 50 条
  • [21] COMPRESSED-XENON IONIZATION CHAMBER FOR GAMMA SPECTROMETRY.
    Dmitrenko, V.V.
    Romanyuk, A.S.
    Suchkov, S.I.
    Uteshev, Z.M.
    Instruments and experimental techniques New York, 1986, 29 (1 pt 1): : 14 - 17
  • [22] COMPRESSED-XENON IONIZATION-CHAMBER FOR GAMMA SPECTROMETRY
    DMITRENKO, VV
    ROMANYUK, AS
    SUCHKOV, SI
    UTESHEV, ZM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1986, 29 (01) : 14 - 17
  • [23] A liquid xenon ionization chamber in an all-fluoropolymer vessel
    LePort, F.
    Pocar, A.
    Bartoszek, L.
    DeVoe, R.
    Fierlinger, P.
    Flatt, B.
    Gratta, G.
    Green, M.
    Koffas, T.
    Diez, M. Montero
    Neilson, R.
    O'Sullivan, K.
    Waldman, S.
    Wodin, J.
    Woisard, D.
    Baussan, E.
    Breidenbach, M.
    Conley, R.
    Fairbank, W., Jr.
    Farine, J.
    Hall, C.
    Hall, K.
    Hallman, D.
    Hargrove, C.
    Hodgson, J.
    Jeng, S.
    Leonard, D. S.
    Mackay, D.
    Martin, Y.
    Odian, A.
    Ounalli, L.
    Piepke, A.
    Prescott, C. Y.
    Rowson, P. C.
    Skarpaas, K.
    Schenker, D.
    Sinclair, D.
    Stekhanov, V.
    Strickland, V.
    Virtue, C.
    Vuilleumier, J.-L.
    Vuilleumier, J.-M.
    Wamba, K.
    Weber, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 578 (02): : 409 - 420
  • [24] AN AIR IONIZATION CHAMBER FOR SOFT X-RAYS
    SEEMANN, HE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1949, 20 (12): : 903 - 907
  • [25] KNK-21A FISSION IONIZATION-CHAMBER FOR MEASURING THE FLUX AND TEMPERATURE OF THERMAL-NEUTRONS IN PULSED SOURCES
    CHUKLYAEV, SV
    PEPELYSHEV, YN
    ATOMIC ENERGY, 1994, 76 (06) : 463 - 467
  • [26] SENSITIVITY OF AN ELECTRET IONIZATION-CHAMBER FOR FAST-NEUTRONS
    PRETZSCH, G
    KERNENERGIE, 1985, 28 (03): : 143 - 145
  • [27] DETERMINATION OF QUALITY FACTOR IN A MIXED FIELD OF GAMMA-RAYS AND NEUTRONS BY AN IONIZATION CHAMBER FILLED WITH A DIELECTRIC LIQUID .2.
    LADU, M
    PELLICCIONI, M
    ROCCELLA, M
    NUCLEAR INSTRUMENTS & METHODS, 1967, 53 (01): : 71 - +
  • [28] Performance of a chamber for studying the liquid xenon response to γ-rays and nuclear recoils
    Neves, F
    Chepel, V
    Solovov, V
    Pereira, A
    Lopes, MI
    da Cunha, JP
    Mendes, P
    Lindote, A
    Silva, CP
    Marques, RF
    Policarpo, AJPL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (06) : 2793 - 2800
  • [29] RADIATION MONITORING AND DISOMETRY WITH PULSED IONIZATION CHAMBER DETECTORS
    DISTENFE.C
    BISHOP, W
    HEALTH PHYSICS, 1965, 11 (08): : 804 - +
  • [30] Design, construction and performance of a liquid xenon and liquid argon ionization chamber
    Imel, D.A.
    Thomas, J.
    Nuclear instruments and methods in physics research, 1988, 273 (01): : 291 - 298