Detection of neutrons and γ rays by a xenon pulsed ionization chamber

被引:5
|
作者
Dmitrenko, V. V. [1 ]
Vlasik, K. F. [1 ]
Grachev, V. M. [1 ]
Dukhvalov, A. G. [1 ]
Ulin, S. E. [1 ]
Uteshev, Z. M. [1 ]
Shustov, A. E. [1 ]
机构
[1] Natl Res Nucl Univ, Moscow Engn Phys Inst MEPhI, Moscow 115409, Russia
关键词
Xenon; Thermal Neutron; Neutron Capture; Radiative Capture; Sensitive Volume;
D O I
10.1134/S0020441212030104
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The applicability of a xenon gamma-ray spectrometer based on a high-pressure (50 atm) xenon cylindrical ionization chamber to thermal neutron detection is discussed. The reaction of radiative capture of thermal neutron capture Xe-131(n, gamma)Xe-132* followed by emission of 668-keV gamma rays detectable by the spectrometer is used. The response of the xenon spectrometer with a sensitive volume of 0.2 L is analyzed. The measured thermal neutron detection efficiency is 0.08%. The advantage of the detector is its capability of simultaneously detecting both thermal neutrons and gamma rays, which allows precise and high-efficiency identification of radioactive and fissile materials.
引用
收藏
页码:419 / 422
页数:4
相关论文
共 50 条
  • [1] Detection of neutrons and γ rays by a xenon pulsed ionization chamber
    V. V. Dmitrenko
    K. F. Vlasik
    V. M. Grachev
    A. G. Dukhvalov
    S. E. Ulin
    Z. M. Uteshev
    A. E. Shustov
    Instruments and Experimental Techniques, 2012, 55 : 419 - 422
  • [2] Detection of γ-rays with a 3.5 1 liquid xenon ionization chamber triggered by the primary scintillation light
    Aprile, E
    Bolotnikov, A
    Chen, DL
    Muhkerjee, R
    Xu, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 480 (2-3): : 636 - 650
  • [3] PERFORMANCE OF A LIQUID XENON IONIZATION-CHAMBER IRRADIATED WITH ELECTRONS AND GAMMA-RAYS
    APRILE, E
    MUKHERJEE, R
    SUZUKI, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 302 (01): : 177 - 185
  • [4] About the Detection of Nuclear Disintegration of cosmic Rays with the Ionization Chamber
    Hoffmann, G.
    ZEITSCHRIFT FUR PHYSIK, 1942, 119 (1-2): : 35 - 42
  • [5] DETECTION OF GAMMA-RAYS IN LIQUID XENON AND MEASUREMENT OF AVERAGE IONIZATION-ENERGY
    GADENNE, MC
    LANSIART, A
    SEIGNEUR, A
    NUCLEAR INSTRUMENTS & METHODS, 1975, 124 (02): : 521 - 526
  • [6] Ion processes in a liquid-xenon ionization chamber under high-intensity pulsed irradiation
    M. A. Kirsanov
    I. M. Obodovskiy
    Instruments and Experimental Techniques, 2010, 53 : 185 - 193
  • [7] Ion processes in a liquid-xenon ionization chamber under high-intensity pulsed irradiation
    Kirsanov, M. A.
    Obodovskiy, I. M.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2010, 53 (02) : 185 - 193
  • [8] Observations of neutrons from cosmic rays in a Wilson chamber
    Mysovskij, L
    Eigenson, M
    COMPTES RENDUS DE L ACADEMIE DES SCIENCES DE L URSS, 1934, 3 : 221 - 224
  • [9] Microstrip gas chamber for X-rays and neutrons
    Hayakawa, Y
    Maeda, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1996, 35 (1B): : L123 - L125
  • [10] The ionization by gamma rays and high in oxygen and xenon.
    Masuch, V.