Do 'passive' medical titanium surfaces deteriorate in service in the absence of wear?

被引:77
作者
Addison, O. [1 ]
Davenport, A. J. [2 ]
Newport, R. J. [3 ]
Kalra, S. [1 ]
Monir, M. [2 ]
Mosselmans, J. F. W. [4 ]
Proops, D. [5 ]
Martin, R. A. [3 ,6 ]
机构
[1] Univ Birmingham, Sch Dent, Biomat Unit, Birmingham, W Midlands, England
[2] Univ Birmingham, Sch Met & Mat, Birmingham B15 2TT, W Midlands, England
[3] Univ Kent, Sch Phys Sci, Canterbury, Kent, England
[4] Diamond Light Source, Div Sci, Didcot, Oxon, England
[5] Univ Hosp Birmingham NHS Fdn Trust, Birmingham, W Midlands, England
[6] Aston Univ, Aston Res Ctr Hlth Ageing, Sch Engn & Appl Sci, Birmingham B4 7ET, W Midlands, England
基金
美国国家卫生研究院;
关键词
titanium; crevice corrosion; microfocus spectroscopy; ANCHORED HEARING-AIDS; METAL-IONS; HIP; TI; TISSUE; CELLS; CR; CO;
D O I
10.1098/rsif.2012.0438
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Globally, more than 1000 tonnes of titanium (Ti) is implanted into patients in the form of biomedical devices on an annual basis. Ti is perceived to be 'biocompatible' owing to the presence of a robust passive oxide film (approx. 4 nm thick) at the metal surface. However, surface deterioration can lead to the release of Ti ions, and particles can arise as the result of wear and/or corrosion processes. This surface deterioration can result in peri-implant inflammation, leading to the premature loss of the implanted device or the requirement for surgical revision. Soft tissues surrounding commercially pure cranial anchorage devices (bone-anchored hearing aid) were investigated using synchrotron X-ray micro-fluorescence spectroscopy and X-ray absorption near edge structure. Here, we present the first experimental evidence that minimal load-bearing Ti implants, which are not subjected to macroscopic wear processes, can release Ti debris into the surrounding soft tissue. As such debris has been shown to be pro-inflammatory, we propose that such distributions of Ti are likely to effect to the service life of the device.
引用
收藏
页码:3161 / 3164
页数:4
相关论文
共 24 条
[1]  
[Anonymous], 2006, COM06S1 MED HEALTHC
[2]   Host inflammatory response to NiCr, CoCr, and Ti in a soft tissue implantation model [J].
Baldwin, L. ;
Hunt, J. A. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2006, 79A (03) :574-581
[3]   The Epidemiology of Revision Total Hip Arthroplasty in the United States [J].
Bozic, Kevin J. ;
Kurtz, Steven M. ;
Lau, Edmund ;
Ong, Kevin ;
Vail, Thomas P. ;
Berry, Daniel J. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (01) :128-133
[4]   Titanium Uptake, Induction of RANK-L Expression, and Enhanced Proliferation of Human T-Lymphocytes [J].
Cadosch, Dieter ;
Sutanto, Michael ;
Chan, Erwin ;
Mhawi, Amir ;
Gautschi, Oliver P. ;
von Katterfeld, Brilliana ;
Simmen, Hans-Peter ;
Filgueira, Luis .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2010, 28 (03) :341-347
[5]   Metal is not inert: Role of metal ions released by biocorrosion in aseptic loosening-Current concepts [J].
Cadosch, Dieter ;
Chan, Erwin ;
Gautschi, Oliver P. ;
Filgueira, Luis .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2009, 91A (04) :1252-1262
[6]   Uptake and intracellular distribution of various metal ions in human monocyte-derived dendritic cells detected by Newport Green™ DCF diacetate ester [J].
Cadosch, Dieter ;
Meagher, James ;
Gautschi, Oliver P. ;
Filgueira, Luis .
JOURNAL OF NEUROSCIENCE METHODS, 2009, 178 (01) :182-187
[7]   Effects of titanium particle size on osteoblast functions in vitro and in vivo [J].
Choi, MG ;
Koh, HS ;
Kluess, D ;
O'Connor, D ;
Mathur, A ;
Truskey, GA ;
Rubin, J ;
Zhou, DXF ;
Sung, KLP .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2005, 102 (12) :4578-4583
[8]   Bone-anchored hearing aids: results of the first eight years of a programme in a district general hospital, assessed by the Glasgow benefit inventory [J].
Gillett, D. ;
Fairley, J. W. ;
Chandrashaker, T. S. ;
Bean, A. ;
Gonzalez, J. .
JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2006, 120 (07) :537-542
[9]   Fluid Exudates From Inflamed Bone-Anchored Hearing Aids Demonstrate Elevated Levels of Cytokines and Biomarkers of Tissue and Bone Metabolism [J].
Grant, Melissa M. ;
Monksfield, Peter ;
Proops, David ;
Brine, Maxine ;
Addison, Owen ;
Sammons, Rachel L. ;
Matthews, John B. ;
Reid, Andrew ;
Chapple, Iain L. C. .
OTOLOGY & NEUROTOLOGY, 2010, 31 (03) :433-439
[10]   CREVICE CORROSION OF TITANIUM IN AQUEOUS SALT SOLUTIONS [J].
GRIESS, JC .
CORROSION, 1968, 24 (04) :96-&