Body Composition Analysis by Air Displacement Plethysmography in Normal Weight to Extremely Obese Adults

被引:16
|
作者
Hames, Kazanna C. [1 ,2 ]
Anthony, Steven J. [2 ]
Thornton, John C. [3 ]
Gallagher, Dympna [3 ]
Goodpaster, Bret H. [2 ]
机构
[1] Univ Pittsburgh, Dept Hlth & Phys Act, Pittsburgh, PA 15260 USA
[2] Univ Pittsburgh, Sch Med, Pittsburgh, PA USA
[3] Columbia Univ, St Lukes Roosevelt Hosp Ctr, Coll Phys & Surg, New York Obes Nutr Res Ctr, New York, NY USA
关键词
X-RAY ABSORPTIOMETRY; VALIDATION; NONOBESE; CHILDREN; SURGERY; DENSITY; MEN;
D O I
10.1002/oby.20655
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To compare body composition parameters estimated by air displacement plethysmography (ADP) to dual X-ray absorptiometry (DXA) in body mass index (BMI) classifications that include extremely obese (BMI >= 40.0 kg/m (2)), and to examine if differences between analyses were influenced by BMI. Methods: Fat-free mass (FFM, kg), fat mass (FM, kg), and body fat (BF, %) were analyzed with both technologies. Results: All outcome measures of ADP and DXA were highly correlated (r >= 0.95, P < 0.001 for FFM, FM, and BF), but Bland-Altman analyses revealed significant bias (P < 0.01 for all). ADP estimated greater FFM and lower FM and BF (P < 0.01 for all). BMI explained 27% of the variance in differences between FFM measurements (P < 0.001), and 37 and 33% of the variances in differences between FM and BF measurements, respectively (P < 0.001 for both). Within normal weight and overweight classifications, ADP estimated greater FFM and lower FM and BF (P < 0.001 for all), but the opposite occurred within the extremely obese classification; ADP estimated lower FFM and greater FM and BF (P < 0.05 for all). Conclusions: Body composition analyses by the two technologies were strongly congruent, but systematically different and influenced by BMI. Caution should be taken when utilizing ADP to estimate body composition parameters over a wide range of BMI classifications that include extremely obese.
引用
收藏
页码:1078 / 1084
页数:7
相关论文
共 50 条
  • [31] Body Composition Analysis of the Clinical Routine Using Air Displacement Plethysmography: Age-Group-Specific Feasibility Analysis among Preterm Infants
    Luecke, Lennart A.
    Rochow, Niels
    Knab, Katja
    Schaefer, Stefan
    Zimmermann, Jasper L.
    Meis, Anastasia
    Lohmueller-Weiss, Stephanie
    Szakacs-Fusch, Adel
    Felderhoff-Mueser, Ursula
    Fusch, Christoph
    NUTRIENTS, 2024, 16 (16)
  • [32] Percentage fat in overweight and obese children: Comparison of DXA and air displacement plethysmography
    Radley, D
    Gately, PJ
    Cooke, CB
    Carroll, S
    Oldroyd, B
    Truscott, JG
    OBESITY RESEARCH, 2005, 13 (01): : 75 - 85
  • [33] Bone mineral density and body composition in normal weight, overweight and obese children
    Lopez-Peralta, Samantha
    Romero-Velarde, Enrique
    Vasquez-Garibay, Edgar M.
    Gonzalez-Hita, Mercedes
    Robles-Robles, Laura C.
    Ruiz-Gonzalez, Francisco J.
    Alejandro Perez-Romero, Misael
    BMC PEDIATRICS, 2022, 22 (01)
  • [34] Bone mineral density and body composition in normal weight, overweight and obese children
    Samantha López-Peralta
    Enrique Romero-Velarde
    Edgar M. Vásquez-Garibay
    Mercedes González-Hita
    Laura C. Robles-Robles
    Francisco J. Ruiz-González
    Misael Alejandro Pérez-Romero
    BMC Pediatrics, 22
  • [35] Comparison of Bioelectrical Impedance Analysis and Air Displacement Plethysmography in Community-Dwelling Older Adults
    Smale, K. Brent
    McIntosh, Emily I.
    Vallis, Lori Ann
    JOURNAL OF APPLIED GERONTOLOGY, 2016, 35 (05) : 474 - 488
  • [36] Fat mass by air-displacement plethysmography and impedance in obese/non-obese children and adolescents
    Azcona, Cristina
    Koeek, Nadia
    Fruehbeck, Gema
    INTERNATIONAL JOURNAL OF PEDIATRIC OBESITY, 2006, 1 (03): : 176 - 182
  • [37] Evaluation of lean tissue density for use in air displacement plethysmography in obese children and adolescents
    Wells, J. C. K.
    Haroun, D.
    Williams, J. E.
    Darch, T.
    Eaton, S.
    Viner, R.
    Fewtrell, M. S.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2011, 65 (10) : 1094 - 1101
  • [38] Comparison of Body Composition Measurement With Whole Body Multifrequency Bioelectrical Impedance and Air Displacement Plethysmography in Healthy Middle-Aged Women
    Benton, Melissa J.
    Swan, Pamela D.
    Schlairet, Maura C.
    Sanderson, Sonya
    HEALTH CARE FOR WOMEN INTERNATIONAL, 2011, 32 (12) : 1068 - 1078
  • [39] Anthropometric and body composition parameters in adolescents with the metabolically obese normal-weight phenotype
    Cota, Bruna Clemente
    Vieira Ribeiro, Sarah Aparecida
    Priore, Silvia Eloiza
    Juvanhol, Leidjaira Lopes
    de Faria, Eliane Rodrigues
    de Faria, Franciane Rocha
    Pereira, Patricia Feliciano
    BRITISH JOURNAL OF NUTRITION, 2022, 127 (10) : 1458 - 1466
  • [40] Challenges in body composition assessment using air-displacement plethysmography by BOD POD in pediatric and young adult patients
    Bijlsma, Alja
    Beijsterveldt, Inge A. L. P. van
    Vermeulen, Marijn J.
    Beunders, Victoria A. A.
    Dorrepaal, Demi J.
    Boeters, Sanne C. M.
    van den Akker, Erica L. T.
    Vlug, Lotte E.
    de Koning, Barbara A. E.
    Bracke, Katrien F. M.
    Dieleman, Gwen C.
    Scheffers, Linda E.
    Hagenaar, Doesjka A.
    Affourtit, Philine
    Bindels-de Heus, Karen G. C. B.
    Hokken-Koelega, Anita C. S.
    Joosten, Koen F. M.
    CLINICAL NUTRITION, 2023, 42 (09) : 1588 - 1594