A Novel Approach for Detection of Myocardial Infarction From ECG Signals of Multiple Electrodes

被引:84
作者
Tripathy, Rajesh Kumar [1 ]
Bhattacharyya, Abhijit [2 ]
Pachori, Ram Bilas [3 ]
机构
[1] Birla Inst Technol & Sci Pilani, Dept Elect & Elect Engn, Hyderabad Campus, Hyderabad 500078, Telangana, India
[2] Natl Inst Technol Andhra Pradesh, Dept Elect & Commun Engn, Tadepalligudem 534102, India
[3] Indian Inst Technol Indore, Discipline Elect Engn, Indore 453552, Madhya Pradesh, India
关键词
Myocardial infarction; 12-lead ECG; FBSE-EWT; clinical information; DL-LSSVM; CLASSIFICATION; LOCALIZATION;
D O I
10.1109/JSEN.2019.2896308
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Myocardial infarction (MI) is also called the heart attack, and it results in the death of heart muscle cells due to the lacking in the supply of oxygen and other nutrients. The early and accurate detection of MI using the 12-lead electrocardiogram (ECG) is helpful in the clinical standard for saving the lives of the patients suffering from this pathology. This paper proposes a novel approach for the detection of MI pathology using the multiresolution analysis of 12-lead ECG signals. The approach is based on the use of Fourier-Bessel series expansion-based empirical wavelet transform (FBSE-EWT) for the time-scale decomposition of 12-lead ECG signals. For each lead ECG signal, nine subband signals are evaluated using FBSE-EWT. The statistical features such as the kurtosis, the skewness, and the entropy are evaluated from the subband signals of each ECG lead. The deep neural network such as the deep layer least-square support-vector machine (DL-LSSVM) which is formulated using the hidden layers of sparse auto-encoders and the LSSVM is used for the detection of MI from the feature vector of 12-lead ECG. The experimental results demonstrate that the combination of FBSE-EWT-based entropy features and DL-LSSVM has the mean accuracy, the mean sensitivity, and the mean specificity values of 99.74%, 99.87%, and 99.60%, respectively, for the detection of MI. The accuracy value of the proposed method is improved by more than 3% as compared to the wavelet-based features for the detection of MI.
引用
收藏
页码:4509 / 4517
页数:9
相关论文
共 51 条
  • [1] Application of deep convolutional neural network for automated detection of myocardial infarction using ECG signals
    Acharya, U. Rajendra
    Fujita, Hamido
    Oh, Shu Lih
    Hagiwara, Yuki
    Tan, Jen Hong
    Adam, Muhammad
    [J]. INFORMATION SCIENCES, 2017, 415 : 190 - 198
  • [2] Automated detection and localization of myocardial infarction using electrocardiogram: a comparative study of different leads
    Acharya, U. Rajendra
    Fujita, Hamido
    Sudarshan, Vidya K.
    Oh, Shu Lih
    Adam, Muhammad
    Koh, Joel E. W.
    Tan, Jen Hong
    Ghista, Dhanjoo N.
    Martis, Roshan Joy
    Chua, Chua K.
    Poo, Chua Kok
    Tan, Ru San
    [J]. KNOWLEDGE-BASED SYSTEMS, 2016, 99 : 146 - 156
  • [3] [Anonymous], DIGIT SIGNAL PROCESS
  • [4] [Anonymous], 2010, NONSTATIONARY SIGNAL
  • [5] [Anonymous], 2008, CHOUS ELECTROCARDIOG
  • [6] [Anonymous], P NAT METR I GERM
  • [7] Ansari Sardar, 2017, IEEE Rev Biomed Eng, V10, P264, DOI 10.1109/RBME.2017.2757953
  • [8] Detection and Localization of Myocardial Infarction using K-nearest Neighbor Classifier
    Arif, Muhammad
    Malagore, Ijaz A.
    Afsar, Fayyaz A.
    [J]. JOURNAL OF MEDICAL SYSTEMS, 2012, 36 (01) : 279 - 289
  • [9] Badilini F., 1992, Proceedings of Computer in Cardiology 1992 (Cat. No.92CH3259-9), P179, DOI 10.1109/CIC.1992.269417
  • [10] Classification of Seizure and Nonseizure EEG Signals Using Empirical Mode Decomposition
    Bajaj, Varun
    Pachori, Ram Bilas
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2012, 16 (06): : 1135 - 1142