A method for red blood cell biotinylation in a closed system

被引:14
作者
de Back, Djuna Z. [1 ,2 ]
Vlaar, Richard [1 ,2 ]
Beuger, Boukje [1 ,2 ]
Daal, Brunette [3 ]
Lagerberg, Johan [3 ]
Vlaar, Alexander P. J. [4 ]
de Korte, Dirk [1 ,2 ,3 ]
van Kraaij, Marian [5 ,6 ]
van Bruggen, Robin [1 ,2 ]
机构
[1] Sanquin Res, Dept Blood Cell Res, Plesmanlaan 125, NL-1066 CX Amsterdam, Netherlands
[2] Univ Amsterdam, Landsteiner Lab, Amsterdam, Netherlands
[3] Sanquin Blood Bank, Dept Prod & Proc Dev, Amsterdam, Netherlands
[4] Acad Med Ctr, Dept Intens Care Med, Amsterdam, Netherlands
[5] Sanquin Res, Sanquin Blood Bank, Dept Donor Affairs, Ctr Clin Transfus Res, Leiden, Netherlands
[6] Sanquin Res, Sanquin Blood Bank, Dept Transfus Med, Ctr Clin Transfus Res, Leiden, Netherlands
关键词
CIRCULATING RBC VOLUME; BIOTIN DENSITIES; IN-VIVO; INFANTS; TRANSFUSION; SURVIVAL; HUMANS; ERYTHROCYTES; ANTIBODIES;
D O I
10.1111/trf.14535
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUNDSeveral circumstances require the accurate measurement of red blood cell (RBC) survival and clearance, such as determination of posttransfusion recovery of stored RBCs to investigate the effect of new additive solutions. To this end, biotin as a marker of RBCs to track donor RBCs in the blood of the recipient has been used in many studies. However, so far only experimental, nonvalidated, biotin-labeled red cell concentrates (RCCs) are transfused. The goal of this study was to produce a standardized biotin-labeled RCC product in a fast, simple, and sterile manner that can be used for clinical research and for the evaluation of new blood products according to Good Practice Guidelines (GPG) for blood establishments. STUDY DESIGN AND METHODSRCC fractions were labeled with two different concentrations of biotinylation reagent in a closed system, to prevent bacterial contamination of the end product. Using flow cytometry, the reproducibility and robustness of the biotin labeling was assessed, as well as the stability of the biotin label on the (un-)irradiated RCC fraction. Additionally, parameters such as phosphatidylserine (PS) exposure, sodium (Na), potassium (K), free hemoglobin, adenosine triphosphate (ATP), pH, and morphology were determined prior to and after biotin labeling to rule out detrimental effects of the labeling procedure on the RCC. RESULTSOur data show that RCCs can be labeled under sterile conditions in a closed system with two different biotinylation reagent concentrations, without affecting the biological activity. CONCLUSIONAn easy, rapid (<2 hr), and robust method was developed to manufacture biotin-labeled RCCs for clinical research compliant to GPG.
引用
收藏
页码:896 / 904
页数:9
相关论文
共 21 条
  • [1] Infants' blood volume in a controlled trial of placental transfusion at preterm delivery
    Aladangady, N
    McHugh, S
    Aitchison, TC
    Wardrop, CAJ
    Holland, BM
    [J]. PEDIATRICS, 2006, 117 (01) : 93 - 98
  • [2] Is it possible to predict the blood volume of a sick preterm infant?
    Aladangady, N
    Aitchison, TC
    Beckett, C
    Holland, BM
    Kyle, BM
    Wardrop, CAJ
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2004, 89 (04): : F344 - F347
  • [3] [Anonymous], 1980, BRIT J HAEMATOL, V45, P659
  • [4] Potassium leakage primes stored erythrocytes for phosphatidylserine exposure and shedding of pro-coagulant vesicles
    Burger, Patrick
    Kostova, Elena
    Bloem, Esther
    Hilarius-Stokman, Petra
    Meijer, Alexander B.
    van den Berg, Timo K.
    Verhoeven, Arthur J.
    de Korte, Dirk
    van Bruggen, Robin
    [J]. BRITISH JOURNAL OF HAEMATOLOGY, 2013, 160 (03) : 377 - 386
  • [5] THE MEASUREMENT OF THE TOTAL VOLUME OF RED-CELLS IN MAN - A NON-RADIOACTIVE APPROACH USING BIOTIN
    CAVILL, I
    TREVETT, D
    FISHER, J
    HOY, T
    [J]. BRITISH JOURNAL OF HAEMATOLOGY, 1988, 70 (04) : 491 - 493
  • [6] Antibodies provoked by the transfusion of biotin-labeled red cells
    Cordle, DG
    Strauss, RG
    Lankford, G
    Mock, DM
    [J]. TRANSFUSION, 1999, 39 (10) : 1065 - 1069
  • [7] Prolonged maintenance of 2,3-diphosphoglycerate acid and adenosine triphosphate in red blood cells during storage
    de Korte, Dirk
    Kleine, Mya
    Korsten, Herbert G. H.
    Verhoeven, Arthur J.
    [J]. TRANSFUSION, 2008, 48 (06) : 1081 - 1089
  • [8] European D irectorate f or t he Quality o f M edicines & H ealthCare, 2017, GUID PREP US QUAL AS
  • [9] Time-dependent changes in the density and hemoglobin F content of biotin-labeled sickle cells
    Franco, RS
    Lohmann, J
    Silberstein, EB
    Mayfield-Pratt, G
    Palascak, M
    Nemeth, TA
    Joiner, CH
    Weiner, M
    Rucknagel, DL
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 1998, 101 (12) : 2730 - 2740
  • [10] BIOTIN LABELING OF RED-CELLS IN THE MEASUREMENT OF RED-CELL VOLUME IN PRETERM INFANTS
    HUDSON, IRB
    CAVILL, IAJ
    COOKE, A
    HOLLAND, BM
    HOY, TG
    TREVETT, D
    TURNER, TL
    WARDROP, CAJ
    [J]. PEDIATRIC RESEARCH, 1990, 28 (03) : 199 - 202