Optimization of keV-settings in abdominal and lower extremity dual-source dual-energy CT angiography determined with virtual monoenergetic imaging

被引:98
|
作者
Sudarski, Sonja [1 ]
Apfaltrer, Paul [1 ]
Nance, John W., Jr. [2 ]
Schneider, David [1 ]
Meyer, Mathias [1 ]
Schoenberg, Stefan O. [1 ]
Fink, Christian [1 ]
Henzler, Thomas [1 ]
机构
[1] Heidelberg Univ, Med Fac Mannheim, Univ Med Ctr Mannheim, Inst Clin Radiol & Nucl Med, D-68167 Mannheim, Germany
[2] Johns Hopkins Univ Hosp, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
关键词
CT angiography; Dual-source CT; Dual-energy CT; Monoenergetic Image quality; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; CONTRAST; QUALITY; SUBTRACTION; ARTERIES; REMOVAL; REPAIR;
D O I
10.1016/j.ejrad.2013.04.040
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To compare objective image quality indices in dual-energy CT angiography (DE-CTA) studies of the abdomen and lower extremity using conventional polyenergetic images (PEIs) and virtual monoenergetic images (MEIs) at different kiloelectron volt (keV) levels. Methods: We retrospectively evaluated 68 dual-source DE-CTA studies. 50 patients (42 men, 71 +/- 10 years) underwent abdominal DE-CTA. 18 patients (13 men, 67 +/- 10 years) underwent lower extremity DE-CTA. MEIs from 40 to 120 keV were reconstructed. Signal intensity, noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were assessed in infrarenal aorta, superior mesenteric, external iliac, femoral, popliteal, and lower leg arteries. Comparisons between MEIs and PEIs were performed with Dunnett's test. Results: 222 arteries were evaluated. In abdominal arteries 70 keV MEIs showed statistically equal signal intensity, noise and CNR levels (+13%; +31%, -14% on average; all p > 0.05) compared to PEIs; SNR was equal or slightly impaired (-7% on average; p < 0.001-1.00). In lower extremity arteries 60 keV MEIs resulted in significantly higher signal intensity and CNR (+54%; +54% on average; all p < 0.05) compared to PEIs at equal noise levels (+18% on average; all p > 0.05) and equal or higher SNR (+49% on average; p < 0.01-0.35). Conclusions: Low-keV MEIs lead to equal or higher signal intensity and CNR compared to PEIs. In lower extremity DE-CTA, additional reconstruction of low-keV MEIs at 60 keV might increase diagnostic confidence. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E574 / E581
页数:8
相关论文
共 50 条
  • [31] Clinical applications of virtual, non-contrast head images derived from dual-source, dual-energy cerebrovascular computed tomography angiography
    Han, D.
    Xie, X. J.
    Wen, L.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2016, 14 (02): : 159 - 163
  • [32] Objective and Subjective Image Quality of Liver Prechyma and Hepatic Metastass with Virtual Monoenergetic Dual-source Dual-energy CT Reconstructions: An Analysis in Patients with Gastrointestinal Stromal Tumor
    Sudarski, Sonja
    Apfaltrer, Paul
    Nance, John W., Jr.
    Meyer, Mathias
    Fink, Christian
    Hohenberger, Peter
    Leidecker, Christianne
    Schoenberg, Stefan O.
    Henzler, Thomas
    ACADEMIC RADIOLOGY, 2014, 21 (04) : 514 - 522
  • [33] Dual-energy CT angiography of pelvic and lower extremity arteries: dual-energy bone subtraction versus manual bone subtraction
    Yamamoto, S.
    McWilliams, J.
    Arellano, C.
    Marfori, W.
    Cheng, W.
    McNamara, T.
    Quinones-Baldrich, W. J.
    Ruehm, S. G.
    CLINICAL RADIOLOGY, 2009, 64 (11) : 1088 - 1096
  • [34] Technical Note: Improved CT number stability across patient size using dual-energy CT virtual monoenergetic imaging
    Michalak, Gregory
    Grimes, Joshua
    Fletcher, Joel
    Halaweish, Ahmed
    Yu, Lifeng
    Leng, Shuai
    McCollough, Cynthia
    MEDICAL PHYSICS, 2016, 43 (01) : 513 - 517
  • [35] Comprehensive Comparison of Virtual Monoenergetic and Linearly Blended Reconstruction Techniques in Third-Generation Dual-Source Dual-Energy Computed Tomography Angiography of the Thorax and Abdomen
    Albrecht, Moritz H.
    Trommer, Jesko
    Wichmann, Julian L.
    Scholtz, Jan-Erik
    Martin, Simon S.
    Lehnert, Thomas
    Vogl, Thomas J.
    Bodelle, Boris
    INVESTIGATIVE RADIOLOGY, 2016, 51 (09) : 582 - 590
  • [36] Application of an Advanced Image-Based Virtual Monoenergetic Reconstruction of Dual Source Dual-Energy CT Data at Low keV Increases Image Quality for Routine Pancreas Imaging
    Hardie, Andrew D.
    Picard, Melissa M.
    Camp, E. Ramsay
    Perry, Jonathan D.
    Suranyi, Pal
    De Cecco, Carlo N.
    Schoepf, U. Joseph
    Wichmann, Julian L.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (05) : 716 - 720
  • [37] Optimisation of window settings for traditional and noise-optimised virtual monoenergetic imaging in dual-energy computed tomography pulmonary angiography
    Tommaso D’Angelo
    Andreas M. Bucher
    Lukas Lenga
    Christophe T. Arendt
    Julia L. Peterke
    Damiano Caruso
    Silvio Mazziotti
    Alfredo Blandino
    Giorgio Ascenti
    Ahmed E. Othman
    Simon S. Martin
    Doris Leithner
    Thomas J. Vogl
    Julian L. Wichmann
    European Radiology, 2018, 28 : 1393 - 1401
  • [38] Dual-Energy CT: Applications in Abdominal Imaging
    Bauer R.W.
    Fischer S.
    Current Radiology Reports, 3 (4)
  • [39] Initial experience of dual-energy lung perfusion CT using a dual-source CT system in children
    Goo, Hyun Woo
    PEDIATRIC RADIOLOGY, 2010, 40 (09) : 1536 - 1544
  • [40] Initial experience of dual-energy lung perfusion CT using a dual-source CT system in children
    Hyun Woo Goo
    Pediatric Radiology, 2010, 40 : 1536 - 1544