Optimization of keV-settings in abdominal and lower extremity dual-source dual-energy CT angiography determined with virtual monoenergetic imaging

被引:98
|
作者
Sudarski, Sonja [1 ]
Apfaltrer, Paul [1 ]
Nance, John W., Jr. [2 ]
Schneider, David [1 ]
Meyer, Mathias [1 ]
Schoenberg, Stefan O. [1 ]
Fink, Christian [1 ]
Henzler, Thomas [1 ]
机构
[1] Heidelberg Univ, Med Fac Mannheim, Univ Med Ctr Mannheim, Inst Clin Radiol & Nucl Med, D-68167 Mannheim, Germany
[2] Johns Hopkins Univ Hosp, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
关键词
CT angiography; Dual-source CT; Dual-energy CT; Monoenergetic Image quality; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; CONTRAST; QUALITY; SUBTRACTION; ARTERIES; REMOVAL; REPAIR;
D O I
10.1016/j.ejrad.2013.04.040
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To compare objective image quality indices in dual-energy CT angiography (DE-CTA) studies of the abdomen and lower extremity using conventional polyenergetic images (PEIs) and virtual monoenergetic images (MEIs) at different kiloelectron volt (keV) levels. Methods: We retrospectively evaluated 68 dual-source DE-CTA studies. 50 patients (42 men, 71 +/- 10 years) underwent abdominal DE-CTA. 18 patients (13 men, 67 +/- 10 years) underwent lower extremity DE-CTA. MEIs from 40 to 120 keV were reconstructed. Signal intensity, noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were assessed in infrarenal aorta, superior mesenteric, external iliac, femoral, popliteal, and lower leg arteries. Comparisons between MEIs and PEIs were performed with Dunnett's test. Results: 222 arteries were evaluated. In abdominal arteries 70 keV MEIs showed statistically equal signal intensity, noise and CNR levels (+13%; +31%, -14% on average; all p > 0.05) compared to PEIs; SNR was equal or slightly impaired (-7% on average; p < 0.001-1.00). In lower extremity arteries 60 keV MEIs resulted in significantly higher signal intensity and CNR (+54%; +54% on average; all p < 0.05) compared to PEIs at equal noise levels (+18% on average; all p > 0.05) and equal or higher SNR (+49% on average; p < 0.01-0.35). Conclusions: Low-keV MEIs lead to equal or higher signal intensity and CNR compared to PEIs. In lower extremity DE-CTA, additional reconstruction of low-keV MEIs at 60 keV might increase diagnostic confidence. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E574 / E581
页数:8
相关论文
共 50 条
  • [21] Virtual unenhanced imaging of the liver with third-generation dual-source dual-energy CT and advanced modeled iterative reconstruction
    De Cecco, Carlo N.
    Muscogiuri, Giuseppe
    Schoepf, U. Joseph
    Caruso, Damiano
    Wichmann, Julian L.
    Cannao, Paola M.
    Canstein, Christian
    Fuller, Stephen R.
    Snider, Lauren
    Varga-Szemes, Akos
    Hardie, Andrew D.
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (07) : 1257 - 1264
  • [22] Liver virtual non-enhanced CT with dual-source, dual-energy CT: a preliminary study
    Long-Jiang Zhang
    Jin Peng
    Sheng-Yong Wu
    Z. Jane Wang
    Xin-Sheng Wu
    Chang-Sheng Zhou
    Xue-Man Ji
    Guang-Ming Lu
    European Radiology, 2010, 20 : 2257 - 2264
  • [23] Determining the Optimal Energy Level of Virtual Monoenergetic Images in Dual-Source CT for Diagnosis of Bowel Obstruction and Colitis
    Lahuna, Loris
    Greffier, Joel
    Goupil, Jean
    Frandon, Julien
    Pastor, Maxime
    De Oliveira, Fabien
    Beregi, Jean Paul
    Dabli, Djamel
    DIAGNOSTICS, 2023, 13 (23)
  • [24] Comparison of dual-source computed tomography (CT) dual-energy angiography with conventional 3D imaging towards caudomedial vessels
    Li, Daowei
    Liu, Na
    Ma, Qiang
    He, Dan
    BIOMEDICAL RESEARCH-INDIA, 2017, 28 (12): : 5445 - 5449
  • [25] Advanced virtual monoenergetic images: improving the contrast of dual-energy CT pulmonary angiography
    Meier, A.
    Wurnig, M.
    Desbiolles, L.
    Leschka, S.
    Frauenfelder, T.
    Alkadhi, H.
    CLINICAL RADIOLOGY, 2015, 70 (11) : 1244 - 1251
  • [26] Abdominal Attenuation Values on Virtual and True Unenhanced Images Obtained With Third-Generation Dual-Source Dual-Energy CT
    Durieux, Pierre
    Gevenois, Pierre Alain
    Van Muylem, Alain
    Howarth, Nigel
    Keyzer, Caroline
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (05) : 1042 - 1058
  • [27] Dual-Energy Computed Tomography for Evaluating Acute Brain Infarction of Middle Cerebral Artery Territories: Optimization of Voltage Settings in Virtual Monoenergetic Imaging
    Yoshida, Morikatsu
    Nakaura, Takeshi
    Tanoue, Shota
    Takada, Sentaro
    Inoue, Taihei
    Uetani, Hiroyuki
    Harada, Kazunori
    Yamashita, Yasuyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (03) : 460 - 466
  • [28] Review of Clinical Applications for Virtual Monoenergetic Dual-Energy CT
    Albrecht, Moritz H.
    Vogl, Thomas J.
    Martin, Simon S.
    Nance, John W.
    Duguay, Taylor M.
    Wichmann, Julian L.
    De Cecco, Carlo N.
    Varga-Szemes, Akos
    van Assen, Marly
    Tesche, Christian
    Schoepf, U. Joseph
    RADIOLOGY, 2019, 293 (02) : 260 - 271
  • [29] Quantitative assessment of motion effects in dual-source dual-energy CT and dual-source photon-counting detector CT
    Ahmed, Zaki
    Rajendran, Kishore
    Gong, Hao
    McCollough, Cynthia
    Leng, Shuai
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [30] Value of low-keV virtual monoenergetic plus dual-energy computed tomographic imaging for detection of acute pulmonary embolism
    Wannasopha, Yutthaphan
    Leesmidt, Kantheera
    Srisuwan, Tanop
    Euathrongchit, Juntima
    Tantraworasin, Apichat
    PLOS ONE, 2022, 17 (11):