Comparison of Balloon Catheter Ablation Technologies for Pulmonary Vein Isolation: The Laser Versus Cryo Study

被引:41
|
作者
Bordignon, Stefano [1 ]
Chun, K. R. Julian [1 ]
Gunawardene, Melanie [1 ]
Fuernkranz, Alexander [1 ]
Urban, Verena [1 ]
Schulte-Hahn, Britta [1 ]
Nowak, Bernd [1 ]
Schmidt, Boris [1 ]
机构
[1] Cardioangiol Ctr Bethanien, D-60431 Frankfurt, Germany
关键词
atrial fibrillation; catheter ablation; cryoballoon; laser; phrenic nerve; PAROXYSMAL ATRIAL-FIBRILLATION; ANTIARRHYTHMIC-DRUG THERAPY; BIG CRYOBALLOON TECHNIQUE; LUMEN MAPPING CATHETER; TRIAL; EFFICACY; FEASIBILITY; MANAGEMENT; INSIGHTS; SYSTEM;
D O I
10.1111/jce.12192
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Laser- Versus CryoBalloon for PVI. Introduction: Balloon catheters have been developed to facilitate pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (PAF). We sought to compare the safety and efficacy of the cryoballoon (CB) and the laserballoon (LB) in a pilot study. Methods and Results: One hundred and forty patients with drug-refractory PAF were prospectively allocated in a 1: 1 fashion to undergo a PVI procedure with the 28 mm CB or the LB and were followed for 12 months using 3-day Holter ECG recording. The primary efficacy endpoint was a documented AF recurrence >= 30 seconds between 90 and 365 days after the index ablation. In total, 269 of 270 PVs (99.6%) and 270 of 273 PVs (98.9%) were acutely isolated in the CB and LB group, respectively. Mean procedural time was 136 +/- 30 minutes for the CB group and 144 +/- 33 minutes for the LB group (P = 0.13). Mean fluoroscopy time was longer in the CB group (21 +/- 9 minutes vs 15 +/- 6 minutes; P < 0.001). During 12 months follow-up, 37% of patients in the CB group and 27% in the LB group experienced an AF recurrence (P = 0.18). Phrenic nerve palsies occurred in 5.7% (CB) and 4.2% (LB) of patients, respectively. Conclusion: Balloon catheters are a viable option to safely perform a PVI procedure in patients with drug-refractory PAF. Ninety-nine percent of PVs may be acutely isolated with a single balloon catheter. The AF free survival rate after a single ablation procedure was not statistically different between groups.
引用
收藏
页码:987 / 994
页数:8
相关论文
共 50 条
  • [41] Pulmonary vein isolation in patients with a left common pulmonary vein: Comparison between second-generation cryoballoon and radiofrequency ablation
    Yamaguchi, Masao
    Miyazaki, Shinsuke
    Kajiyama, Takatsugu
    Hada, Masahiro
    Nakamura, Hiroaki
    Hachiya, Hitoshi
    Iesaka, Yoshito
    JOURNAL OF CARDIOLOGY, 2019, 73 (3-4) : 292 - 298
  • [42] Radiofrequency Catheter Ablation Targeting the Vein of Marshall in Difficult Mitral Isthmus Ablation or Pulmonary Vein Isolation
    Lee, Ji Hyun
    Nam, Gi-Byoung
    Kim, Minsu
    Hwang, You Mi
    Hwang, Jongmin
    Kim, Jun
    Choi, Kee-Joon
    Kim, You-Ho
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (04) : 386 - 393
  • [43] Cryoballoon ablation for pulmonary vein isolation
    Andrade, Jason G.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (08) : 2128 - 2135
  • [44] Comparison of ThermoCool® Surround Flow Catheter Versus ThermoCool® Catheter in Achieving Persistent Electrical Isolation of Pulmonary Veins: A Pilot Study
    Bertaglia, Emanuele
    Fassini, Gaetano
    Anselmino, Matteo
    Stabile, Giuseppe
    Grandinetti, Giuseppe
    De Simone, Antonio
    Calo, Leonardo
    Pandozi, Claudio
    Pratola, Claudio
    Zoppo, Franco
    Tondo, Claudio
    Iuliano, Assunta
    Gaita, Fiorenzo
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (03) : 269 - 273
  • [45] Verification of a novel atrial fibrillation cryoablation dosing algorithm guided by time-to-pulmonary vein isolation: Results from the Cryo-DOSING Study (Cryoballoon-ablation DOSING Based on the Assessment of Time-to-Effect and Pulmonary Vein Isolation Guidance)
    Aryana, Arash
    Kenigsberg, David N.
    Kowalski, Marcin
    Koo, Charles H.
    Lim, Hae W.
    O'Neill, Padraig Gearoid
    Bowers, Mark R.
    Hokanson, Robert B.
    Ellenbogen, Kenneth A.
    HEART RHYTHM, 2017, 14 (09) : 1319 - 1325
  • [46] Incidence of Asymptomatic Intracranial Embolic Events After Pulmonary Vein Isolation Comparison of Different Atrial Fibrillation Ablation Technologies in a Multicenter Study
    Siklody, Claudia Herrera
    Deneke, Thomas
    Hocini, Meleze
    Lehrmann, Heiko
    Shin, Dong-In
    Miyazaki, Shinsuke
    Henschke, Susanne
    Fluegel, Peter
    Schiebeling-Roemer, Jochen
    Bansmann, Paul M.
    Bourdias, Thomas
    Dousset, Vincent
    Haissaguerre, Michel
    Arentz, Thomas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (07) : 681 - 688
  • [47] Preclinical evaluation of semi-automated laser ablation for pulmonary vein isolation: A comparative study
    Kuroki, Kenji
    Reddy, Vivek Y.
    Iwasawa, Jin
    Kawamura, Iwanari
    Neuzil, Petr
    Estabrook, Brian
    Melsky, Gerald
    Dukkipati, Srinivas R.
    Koruth, Jacob
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (02) : 315 - 324
  • [48] Statistical Model of Paroxysmal Atrial Fibrillation Catheter Ablation Targets for Pulmonary Vein Isolation
    Al-Agamy, Ahmad
    Karim, Rashed
    Arujuna, Aruna
    Harrison, James L.
    Williams, Steven E.
    Rhode, Kawal S.
    van Assen, Hans C.
    STATISTICAL ATLASES AND COMPUTATIONAL MODELS OF THE HEART: IMAGING AND MODELLING CHALLENGES, 2015, 8896 : 221 - 230
  • [49] Pulmonary Vein Isolation Using a Second-Generation Cryoballoon Catheter: A Randomized Comparison of Ablation Duration and Method of Deflation
    Andrade, Jason G.
    Dubuc, Marc
    Guerra, Peter G.
    Landry, Evelyn
    Coulombe, Nicolas
    Leduc, Hugues
    Rivard, Lena
    Macle, Laurent
    Thibault, Bernard
    Talajic, Mario
    Roy, Denis
    Khairy, Paul
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (06) : 692 - 698
  • [50] Fiberoptic balloon catheter ablation of pulmonary vein ostia in pigs using photonic energy delivery with diode laser
    Lemery, R
    Veinot, JP
    Tang, ASL
    Green, M
    Farr, N
    Baxter, L
    McIntyre, J
    Sinofsky, E
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (01): : 32 - 36