An assessment of claims of 'excess heat' in 'cold fusion' calorimetry

被引:4
|
作者
Shelton, DS
Hansen, LD
Thorne, JM
Jones, SE
机构
[1] BRIGHAM YOUNG UNIV,DEPT CHEM,PROVO,UT 84602
[2] BRIGHAM YOUNG UNIV,DEPT PHYS,PROVO,UT 84602
[3] UNIV CLERMONT FERRAND,LAB THERMODYNAM & GENIE CHEM,F-63177 AUBIERE,FRANCE
关键词
calibration; calorimetry; cold fusion; excess heat;
D O I
10.1016/S0040-6031(97)00160-3
中图分类号
O414.1 [热力学];
学科分类号
摘要
Claims of 'excess heat' from measurements of the heat of electrolysis at several watts of power are largely based on use of poorly characterized, isoperibol, heat-conduction calorimeters with single-point temperature sensors. This paper describes construction, testing, and calibration of a calorimeter of similar design. Heat-conduction calorimeters with single-point temperature sensing and inadequate mixing are subject to large systematic errors resulting from non-uniform heat distribution within the system. Confirmation of electric-heater calibration by a chemical reaction with a well-known enthalpy change is a minimum requirement to insure accuracy. Improper or incomplete calibration is a probable cause for many claims of 'excess heat' in 'cold fusion' experiments. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:7 / 15
页数:9
相关论文
共 50 条
  • [41] Measuring the heat of wetting of textile fibres by reaction calorimetry
    Varga, Ksenija
    Schaedel, Uta
    Nilsson, Holger
    Persson, Olof
    Schuster, K. Christian
    FIBRES & TEXTILES IN EASTERN EUROPE, 2007, 15 (5-6) : 59 - 63
  • [42] Heat release rate calculation in oxygen consumption calorimetry
    Chow, W. K.
    Han, S. S.
    APPLIED THERMAL ENGINEERING, 2011, 31 (2-3) : 304 - 310
  • [43] Cold Fusion - CMNS - LENR; Past, Present and Projected Future Status
    McKubre, Michael C. H.
    JOURNAL OF CONDENSED MATTER NUCLEAR SCIENCE, 2016, 19 : 183 - 191
  • [44] A neutron detector for cold fusion experiments
    Cisbani, E
    Urciuoli, GM
    Frullani, S
    Garibaldi, F
    Giuliani, F
    Gozzi, D
    Gricia, M
    Iodice, M
    Lucentini, M
    Santavenere, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 459 (1-2) : 247 - 255
  • [45] CORROBORATING EVIDENCE FOR COLD FUSION REACTION
    ARATA, Y
    ZHANG, YC
    PROCEEDINGS OF THE JAPAN ACADEMY SERIES B-PHYSICAL AND BIOLOGICAL SCIENCES, 1990, 66 (06): : 110 - 115
  • [46] SEARCH FOR NEUTRONS AS EVIDENCE OF COLD FUSION
    CANNIZZARO, F
    GRECO, G
    RANELI, M
    SPITALE, MC
    TOMARCHIO, E
    FUSION TECHNOLOGY, 1992, 21 (01): : 86 - 91
  • [47] Full atomic theory of cold fusion
    Gou, Qing-Quan
    JOURNAL OF ATOMIC AND MOLECULAR SCIENCES, 2010, 1 (01): : 87 - 92
  • [48] Hot and Cold Fusion for Energy Generation
    Nagel, David J.
    JOURNAL OF CONDENSED MATTER NUCLEAR SCIENCE, 2011, 4 : 1 - 16
  • [49] Overcoming the Coulomb Barrier in Cold Fusion
    Chubb, Talbot A.
    Chubb, Scott R.
    JOURNAL OF CONDENSED MATTER NUCLEAR SCIENCE, 2009, 2 : 51 - 59
  • [50] Study on Physical Basis of Cold Fusion
    李家全
    沈丽如
    李国盛
    李炯
    Plasma Science & Technology, 2002, (06) : 1585 - 1589