摘要
Background and aim In a combined positron emission tomography (PET) and computed tomography (CT) system, the CT images can be used for attenuation correction as well as for image fusion. However, quantitative and qualitative differences have been reported between CT based attenuation corrected PET and conventional transmission scan corrected PET images. The purpose of this study was to investigate potential differences in PET/ CT caused by attenuation differences in bowel due to motion. Methods Twelve patients had PET/CT scans performed using Ge-68 transmission and CT attenuation correction methods. Three emission imaging datasets were generated including CT corrected PET, Ge corrected PET, and the difference images (CT corrected PET minus Ge corrected PET). PET difference images were used to identify regions of mismatch and to quantify possible discordance between images by using standardized uptake values (SUVs). Using the Ge corrected PET as the standard, differences in emission images were classified as an overestimation (pattern A) or an underestimation (pattern B) in these difference images. Results One hundred and twenty-three mismatched areas were identified. Among them, overestimated areas in CT corrected image were detected in 36 regions (pattern A), while underestimated areas were evaluated in the remaining 87 regions (pattern B). The mean value of the difference in pattern A (mean standard deviation = 0.84 +/- 0.44) was slightly higher than that in pattern B (0.60 +/- 0.23), and statistically significant. Six of 36 regions in pattern A had an SUV of greater than 2.5 in CT corrected PET but less than 2.5 in Ge corrected PET; two of 87 regions with pattern B demonstrated an SUV greater than 2.5 in Ge corrected PET and less than 2.5 in CT corrected PET. Conclusion Physiological bowel motion may result in attenuation differences and subsequent differences in SUVs. Overestimation of fluorodeoxyglucose uptake should not be misinterpreted as disease.
引用
收藏
页码:221 / 225
页数:5
相关论文
共 18 条
[1]   PET imaging in oncology [J].
Bar-Shalom, R ;
Valdivia, AY ;
Blaufox, MD .
SEMINARS IN NUCLEAR MEDICINE, 2000, 30 (03) :150-185
[2]  
Beyer T, 2000, J NUCL MED, V41, P1369
[3]   Clinical role of positron emission tomography in oncology [J].
Bomanji, J. B. ;
Costa, D. C. ;
Ell, P. J. .
LANCET ONCOLOGY, 2001, 2 (03) :157-164
[4]   Normal physiological and benign pathological variants of 18-fluoro-2-deoxyglucose positron-emission tomography scanning: Potential for error in interpretation [J].
Cook, GJR ;
Fogelman, I ;
Maisey, MN .
SEMINARS IN NUCLEAR MEDICINE, 1996, 26 (04) :308-314
[5]   Additional value of whole-body positron emission tomography with fluorine-18-2-fluoro-2-deoxy-D-glucose in recurrent colorectal cancer [J].
Flamen, P ;
Stroobants, S ;
Van Cutsem, E ;
Dupont, P ;
Bormans, G ;
De Vadder, N ;
Penninckx, F ;
Van Hoe, L ;
Mortelmans, L .
JOURNAL OF CLINICAL ONCOLOGY, 1999, 17 (03) :894-901
[6]   Unexplained rising carcinoembryonic antigen (CEA) in the postoperative surveillance of colorectal cancer: the utility of positron emission tomography (PET) [J].
Flamen, P ;
Hoekstra, OS ;
Homans, F ;
Van Cutsem, E ;
Maes, A ;
Stroobants, S ;
Peeters, M ;
Penninckx, F ;
Filez, L ;
Bleichrodt, RP ;
Mortelmans, L .
EUROPEAN JOURNAL OF CANCER, 2001, 37 (07) :862-869
[7]   PET-CT image co-registration in the thorax: influence of respiration [J].
Goerres, GW ;
Kamel, E ;
Heidelberg, TNH ;
Schwitter, MR ;
Burger, C ;
von Schulthess, GK .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (03) :351-360
[8]  
HAMACHER K, 1986, J NUCL MED, V27, P235
[9]   PET-CT-guided percutaneous puncture of an infected cyst in autosomal dominant polycystic kidney disease: Case report [J].
Kaim, AH ;
Burger, C ;
Ganter, CC ;
Goerres, GW ;
Kamel, E ;
Weishaupt, D ;
Dizendorf, E ;
Schaffner, A ;
von Schulthess, GK .
RADIOLOGY, 2001, 221 (03) :818-821
[10]   CT vs 68Ge attenuation correction in a combined PET/CT system:: evaluation of the effect of lowering the CT tube current [J].
Kamel, E ;
Hany, TF ;
Burger, C ;
Treyer, V ;
Lonn, AHR ;
von Schulthess, GK ;
Buck, A .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (03) :346-350