Relationship of EEG sources of neonatal seizures to acute perinatal brain lesions seen on MRI: A pilot study

被引:17
作者
Despotovic, Ivana [1 ]
Cherian, Perumpillichira J. [2 ]
De Vos, Maarten [3 ,4 ,5 ]
Hallez, Hans [1 ]
Deburchgraeve, Wouter [3 ,4 ]
Govaert, Paul [6 ]
Lequin, Maarten [7 ]
Visser, Gerhard H. [2 ]
Swarte, Renate M. [6 ]
Vansteenkiste, Ewout [1 ]
Van Huffel, Sabine [3 ,4 ]
Philips, Wilfried [1 ]
机构
[1] Univ Ghent, MDISIP IPI IBBT, B-9000 Ghent, Belgium
[2] Univ Med Ctr Rotterdam, Erasmus MC, Dept Clin Neurophysiol, NL-3015 CE Rotterdam, Netherlands
[3] Katholieke Univ Leuven, Dept Elect Engn ESAT SCD SISTA, B-3001 Louvain, Belgium
[4] Katholieke Univ Leuven, IBBT Future Hlth Dept, B-3001 Louvain, Belgium
[5] Carl von Ossietzky Univ Oldenburg, Dept Psychol, Neuropsychol Lab, D-26111 Oldenburg, Germany
[6] Erasmus MC Sophia, Dept Neonatol, NL-3015 GJ Rotterdam, Netherlands
[7] Erasmus MC Sophia, Dept Pediat Radiol, NL-3015 GJ Rotterdam, Netherlands
关键词
neonates; MRI; realistic head model; EEG; source localization; asphyxia; HIE; HYPOXIC-ISCHEMIC ENCEPHALOPATHY; FINITE-DIFFERENCE METHOD; SOURCE LOCALIZATION; IN-VIVO; ELECTROGRAPHIC SEIZURES; AUTOMATIC SEGMENTATION; LOCATION ERRORS; INVERSE PROBLEM; ELECTROENCEPHALOGRAM; MODEL;
D O I
10.1002/hbm.22076
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Even though it is known that neonatal seizures are associated with acute brain lesions, the relationship of electroencephalographic (EEG) seizures to acute perinatal brain lesions visible on magnetic resonance imaging (MRI) has not been objectively studied. EEG source localization is successfully used for this purpose in adults, but it has not been sufficiently explored in neonates. Therefore, we developed an integrated method for ictal EEG dipole source localization based on a realistic head model to investigate the utility of EEG source imaging in neonates with postasphyxial seizures. We describe here our method and compare the dipole seizure localization results with acute perinatal lesions seen on brain MRI in 10 full-term infants with neonatal encephalopathy. Through experimental studies, we also explore the sensitivity of our method to the electrode positioning errors and the variations in neonatal skull geometry and conductivity. The localization results of 45 focal seizures from 10 neonates are compared with the visual analysis of EEG and MRI data, scored by expert physicians. In 9 of 10 neonates, dipole locations showed good relationship with MRI lesions and clinical data. Our experimental results also suggest that the variations in the used values for skull conductivity or thickness have little effect on the dipole localization, whereas inaccurate electrode positioning can reduce the accuracy of source estimates. The performance of our fused method indicates that ictal EEG source imaging is feasible in neonates and with further validation studies, this technique can become a useful diagnostic tool. Hum Brain Mapp 34:2402-2417, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:2402 / 2417
页数:16
相关论文
共 72 条
  • [61] VARIATION WITH AGE OF THE DIELECTRIC-PROPERTIES OF MOUSE-BRAIN CEREBRUM
    THURAI, M
    GOODRIDGE, VD
    SHEPPARD, RJ
    GRANT, EH
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (09) : 1133 - 1136
  • [62] Influence of measurement noise and electrode mislocalisation on EEG dipole-source localisation
    Van Hoey, G
    Vanrumste, B
    D'Havé, M
    Van de Walle, R
    Lemahieu, I
    Boon, P
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (03) : 287 - 296
  • [63] High-fidelity recording of brain activity in the extremely preterm babies:: Feasibility study in the incubator
    Vanhatalo, Sampsa
    Metsaeranta, Marjo
    Andersson, Sture
    [J]. CLINICAL NEUROPHYSIOLOGY, 2008, 119 (02) : 439 - 445
  • [64] Dipole location errors in electroencephalogram source analysis due to volume conductor model errors
    Vanrumste, B
    Van Hoey, G
    Van de Walle, R
    D'Havé, M
    Lemahieu, I
    Boon, P
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (05) : 528 - 534
  • [65] The validation of the finite difference method and reciprocity for solving the inverse problem in EEG dipole source analysis
    Vanrumste, B
    Van Hoey, G
    Van de Walle, R
    D'Havé, MRP
    Lemahieu, IA
    Boon, PAJM
    [J]. BRAIN TOPOGRAPHY, 2001, 14 (02) : 83 - 92
  • [66] Volpe J., 2008, NEUROLOGY NEWBORN
  • [67] PARASAGITTAL CEREBRAL INJURY IN NEONATAL HYPOXIC-ISCHEMIC ENCEPHALOPATHY - CLINICAL AND NEURORADIOLOGIC FEATURES
    VOLPE, JJ
    PASTERNAK, JF
    [J]. JOURNAL OF PEDIATRICS, 1977, 91 (03) : 472 - 476
  • [68] The influence of electrode location errors on EEG dipole source localization with a realistic head model
    Wang, YH
    Gotman, J
    [J]. CLINICAL NEUROPHYSIOLOGY, 2001, 112 (09) : 1777 - 1780
  • [69] BEHAVIORAL STATE CYCLES, BACKGROUND EEGS AND PROGNOSIS OF NEWBORNS WITH PERINATAL HYPOXIA
    WATANABE, K
    MIYAZAKI, S
    HARA, K
    HAKAMADA, S
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1980, 49 (5-6): : 618 - 625
  • [70] Automatic segmentation of newborn brain MRI
    Weisenfeld, Neil I.
    Warfield, Simon K.
    [J]. NEUROIMAGE, 2009, 47 (02) : 564 - 572