Experimental and CFD study of unsteady airborne pollutant transport within an aircraft cabin mock-up

被引:101
作者
Yan, Wei [1 ]
Zhang, Yuanhui [1 ]
Sun, Yigang [1 ]
Li, Dongning [1 ]
机构
[1] Univ Illinois, Dept Agr & Biol Engn, Urbana, IL 61801 USA
关键词
Indoor air quality; Computational fluid dynamics; Tracer gas; Aircraft cabins; Ventilation; COMPUTATIONAL FLUID-DYNAMICS; AIR-FLOW; NUMERICAL-SIMULATION; PATHOGEN TRANSPORT; PART I; QUALITY;
D O I
10.1016/j.buildenv.2008.01.010
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It has been documented that diseases can spread within an aircraft cabin from the sneezing, coughing or breathing of it sick passenger. To understand the spreading mechanism it is very important to quantify the airflow and droplet transmission around a sneezing/ coughing incident. In this project, tracer gas experiments were carried out in a full-scale Bocing 767-300 mock-up to study the global transport process of contaminated air within the cabin. Computational fluid dynamics (CFD) simulation was also used to provide additional information for understanding the principle. A steady airflow field was simulated first and then it was compared with the experimental data. The global airflow patterns were similar to those observed experimentally. This velocity field was adopted as the initial condition for further unsteady pollutant transport simulation. Experimental and simulated results were compared and discussed to develop a relationship between concentration and airflow pattern, source location, transport direction, and ventilation rate. Finally, the overall picture of concentration evolution by both experimental and simulated approaches was discussed. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:34 / 43
页数:10
相关论文
共 26 条
[1]  
ABOOSAIDI F, 1991, P SOC AUTOMOTIVE ENG, V246, P249
[2]  
[Anonymous], 2002, AIRL CAB ENV HLTH PA
[3]  
Chou PC, 1998, INDOOR BUILT ENVIRON, V7, P300, DOI 10.1159/000024598
[4]   Pollutant dispersion in a large indoor space. Part 2: Computational fluid dynamics predictions and comparison with a scale model experiment for isothermal flow [J].
Finlayson, EU ;
Gadgil, AJ ;
Thatcher, TL ;
Sextro, RG .
INDOOR AIR, 2004, 14 (04) :272-283
[5]  
HOCKING M, 2002, J AM IND HYGIENE ASS, V59, P446
[6]  
Lin CH, 2005, ASHRAE TRAN, V111, P755
[7]  
Lin CH, 2005, ASHRAE TRAN, V111, P764
[8]   Health and perception of cabin air quality among Swedish commercial airline crew [J].
Lindgren, T ;
Norbäck, D .
INDOOR AIR, 2005, 15 :65-72
[9]   Cabin air quality:: indoor pollutants and climate during intercontinental flights with and without tobacco smoking [J].
Lindgren, T ;
Norbäck, D .
INDOOR AIR, 2002, 12 (04) :263-272
[10]   Transmission of the severe acute respiratory syndrome on aircraft [J].
Olsen, SJ ;
Chang, H ;
Cheung, TY ;
Tang, AF ;
Fisk, TL ;
Ooi, SP ;
Kuo, H ;
Jiang, DD ;
Chen, K ;
Lando, J ;
Hsu, K ;
Chen, T ;
Dowell, SF .