Monte Carlo modeling and validation of a proton treatment nozzle by using the Geant4 toolkit

被引:5
|
作者
Kim, Dae-Hyun [1 ,2 ,3 ]
Kang, Young Nam [1 ]
Suh, Tae-Suk [2 ,3 ]
Shin, Jungwook [4 ]
Kim, Jong Won [5 ]
Yoo, Seung Hoon [6 ]
Park, Seyjoon [7 ]
Lee, Sang Hoon [7 ]
Cho, Sungkoo [7 ]
Shin, Dongho [7 ]
Kim, Dae Yong [7 ]
Lee, Se Byeong [7 ]
机构
[1] Catholic Univ Korea, Dept Radiat Oncol, Seoul St Marys Hosp, Coll Med, Seoul 137701, South Korea
[2] Catholic Univ Korea, Dept Biomed Engn, Coll Med, Seoul 137701, South Korea
[3] Catholic Univ Korea, Res Inst Biomed Engn, Coll Med, Seoul 137701, South Korea
[4] Univ Calif San Francisco, Helen Diller Family Comprehens Canc Ctr, Dept Radiat Oncol, San Francisco, CA 94143 USA
[5] Kwandong Univ, Dept Radiat Oncol, Myongji Hosp, Coll Med, Goyang 412270, South Korea
[6] CHA Univ, CHA Bundang Med Cente, Dept Radiat Oncol, Songnam 463712, South Korea
[7] Natl Canc Ctr, Proton Therapy Ctr, Goyang 410769, South Korea
基金
新加坡国家研究基金会;
关键词
Commissioning; Geant4; Monte Carlo simulation; Proton therapy; Validation; BEAM DELIVERY-SYSTEM; DOSE CALCULATION; SIMULATION; IMPLEMENTATION; SPACE;
D O I
10.3938/jkps.61.1125
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Modern commercial treatment planning systems for proton therapy use the pencil beam algorithm for calculating the absorbed dose. Although it is acceptable for clinical radiation treatment, the accuracy of this method is limited. Alternatively, the Monte Carlo method, which is relatively accurate in dose calculations, has been applied recently to proton therapy. To reduce the remaining uncertainty in proton therapy dose calculations, in the present study, we employed Monte Carlo simulations and the Geant4 simulation toolkit to develop a model for a of a proton treatment nozzle. The results from a Geant4-based medical application of the proton treatment nozzle were compared to the measured data. Simulations of the percentage depth dose profiles showed very good agreement within 1 mm in distal range and 3 mm in modulated width. Moreover, the lateral dose profiles showed good agreement within 3% in the central region of the field and within 10% in the penumbra regions. In this work, we proved that the Geant4 Monte Carlo model of a proton treatment nozzle could be used to the calculate proton dose distributions accurately.
引用
收藏
页码:1125 / 1130
页数:6
相关论文
共 50 条
  • [41] Detailed optimization procedure of an HPGe detector using Geant4 toolkit
    M. Travar
    J. Nikolov
    N. Todorović
    A. Vraničar
    P. Völgyesi
    P. Kirchknopf
    I. Čeliković
    T. Milanović
    D. Joković
    Journal of Radioanalytical and Nuclear Chemistry, 2023, 332 : 817 - 828
  • [42] A CUDA Monte Carlo simulator for radiation therapy dosimetry based on Geant4
    Henderson, N.
    Murakami, K.
    Amako, K.
    Asai, M.
    Aso, T.
    Dotti, A.
    Kimura, A.
    Gerritsen, M.
    Kurashige, H.
    Perl, J.
    Sasaki, T.
    SNA + MC 2013 - JOINT INTERNATIONAL CONFERENCE ON SUPERCOMPUTING IN NUCLEAR APPLICATIONS + MONTE CARLO, 2014,
  • [43] Experimental validation of proton physics models of Geant4 for calculating stopping power ratio
    Liu, Ruirui
    Zhao, Xiandong
    Medrano, Maria
    JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (02)
  • [44] Validation of Geant4 Physics Models for the Simulation of the Proton Bragg Peak
    Cirrone, G. A. P.
    Cuttone, G.
    Di Rosa, F.
    Guatelli, S.
    Mascialino, B.
    Pia, M. G.
    Russo, G.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 788 - 792
  • [45] Studies of the radiation environment on the Mars surface using the Geant4 toolkit
    Chen, Jun-Liang
    Yun, Su-Jun
    Dong, Tie-Kuang
    Ren, Zhong-Zhou
    Zhang, Xiao-Ping
    NUCLEAR SCIENCE AND TECHNIQUES, 2022, 33 (01)
  • [46] Extended in-field and out-of-field validation of a compact Monte Carlo model of an IBA PROTEUS®ONE proton beam in TOPAS/GEANT4
    Colson, Dries
    Blommaert, Jeroen
    Poels, Kenneth
    De Saint-Hubert, Marijke
    Reniers, Brigitte
    Depuydt, Tom
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (21)
  • [47] Evaluation of Effective Parameters on a Simple Muon Detector Efficiency Using GEANT4 Monte Carlo Model
    Khalifeh, Z.
    Rad, S. Z. Islami
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2022, 19 (03) : 235 - 240
  • [48] Evaluation of Effective Parameters on a Simple Muon Detector Efficiency Using GEANT4 Monte Carlo Model
    Z. Khalifeh
    S. Z. Islami rad
    Physics of Particles and Nuclei Letters, 2022, 19 : 235 - 240
  • [49] Monte Carlo simulation of NovalisTx linear accelerator using GATE/Geant4 code for dosimetry analysis
    Fathi, Ahmed
    Khobbaizi, Youness
    Nabil, Sanaa
    Ardouz, Anas
    Hasnaoui, Abdellatif
    Sbiaai, Khalid
    MATERIALS TODAY-PROCEEDINGS, 2022, 66 : 466 - 472
  • [50] The effect of 111In radionuclide distance and auger electron energy on direct induction of DNA double-strand breaks: a Monte Carlo study using Geant4 toolkit
    Piroozfar, Behnaz
    Raisali, Gholamreza
    Alirezapour, Behrouz
    Mirzaii, Mohammad
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2018, 94 (04) : 385 - 393