Monte Carlo modeling and validation of a proton treatment nozzle by using the Geant4 toolkit

被引:5
|
作者
Kim, Dae-Hyun [1 ,2 ,3 ]
Kang, Young Nam [1 ]
Suh, Tae-Suk [2 ,3 ]
Shin, Jungwook [4 ]
Kim, Jong Won [5 ]
Yoo, Seung Hoon [6 ]
Park, Seyjoon [7 ]
Lee, Sang Hoon [7 ]
Cho, Sungkoo [7 ]
Shin, Dongho [7 ]
Kim, Dae Yong [7 ]
Lee, Se Byeong [7 ]
机构
[1] Catholic Univ Korea, Dept Radiat Oncol, Seoul St Marys Hosp, Coll Med, Seoul 137701, South Korea
[2] Catholic Univ Korea, Dept Biomed Engn, Coll Med, Seoul 137701, South Korea
[3] Catholic Univ Korea, Res Inst Biomed Engn, Coll Med, Seoul 137701, South Korea
[4] Univ Calif San Francisco, Helen Diller Family Comprehens Canc Ctr, Dept Radiat Oncol, San Francisco, CA 94143 USA
[5] Kwandong Univ, Dept Radiat Oncol, Myongji Hosp, Coll Med, Goyang 412270, South Korea
[6] CHA Univ, CHA Bundang Med Cente, Dept Radiat Oncol, Songnam 463712, South Korea
[7] Natl Canc Ctr, Proton Therapy Ctr, Goyang 410769, South Korea
基金
新加坡国家研究基金会;
关键词
Commissioning; Geant4; Monte Carlo simulation; Proton therapy; Validation; BEAM DELIVERY-SYSTEM; DOSE CALCULATION; SIMULATION; IMPLEMENTATION; SPACE;
D O I
10.3938/jkps.61.1125
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Modern commercial treatment planning systems for proton therapy use the pencil beam algorithm for calculating the absorbed dose. Although it is acceptable for clinical radiation treatment, the accuracy of this method is limited. Alternatively, the Monte Carlo method, which is relatively accurate in dose calculations, has been applied recently to proton therapy. To reduce the remaining uncertainty in proton therapy dose calculations, in the present study, we employed Monte Carlo simulations and the Geant4 simulation toolkit to develop a model for a of a proton treatment nozzle. The results from a Geant4-based medical application of the proton treatment nozzle were compared to the measured data. Simulations of the percentage depth dose profiles showed very good agreement within 1 mm in distal range and 3 mm in modulated width. Moreover, the lateral dose profiles showed good agreement within 3% in the central region of the field and within 10% in the penumbra regions. In this work, we proved that the Geant4 Monte Carlo model of a proton treatment nozzle could be used to the calculate proton dose distributions accurately.
引用
收藏
页码:1125 / 1130
页数:6
相关论文
共 50 条
  • [31] Geant4 and Beyond: Precision Physics Modeling and Validation
    Basaglia, Tullio
    Batic, Matej
    Begalli, Marcia
    Han, Min Cheol
    Hauf, Steffen
    Hoff, Gabriela
    Kim, Chan Hyeong
    Kim, Han Sung
    Kim, Sung Hun
    Kuster, Markus
    Pia, Maria Grazia
    Saracco, Paolo
    Weidenspointer, Georg
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [32] Validation of GEANT4 Monte Carlo Simulation Code for 6 MV Varian Linac Photon Beam
    Salama, E.
    Ali, A. S.
    Emad, N.
    Radi, A.
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2015, 48 (02): : 70 - 76
  • [33] On the ionizing radiation protection properties of different chromium-based alloys: A study with the Geant4 Monte Carlo toolkit
    Hamad, Morad Kh.
    ANNALS OF NUCLEAR ENERGY, 2025, 213
  • [34] Geant4 toolkit for simulation of HEP experiments
    Ivanchenko, VN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 502 (2-3) : 666 - 668
  • [35] Determination of Position Resolution for LYSO Scintillation Crystals Using Geant4 Monte Carlo Code
    Yahya, M. F. O.
    Kocak, F.
    ADVANCES IN HIGH ENERGY PHYSICS, 2021, 2021 (2021)
  • [36] Multiple scattering of 13 and 20 MeV electrons by thin foils: A Monte Carlo study with GEANT, Geant4, and PENELOPE
    Vilches, M.
    Garcia-Pareja, S.
    Guerrero, R.
    Anguiano, M.
    Lallena, A. M.
    MEDICAL PHYSICS, 2009, 36 (09) : 3964 - 3970
  • [37] Monte Carlo simulation of pixelated CZT detector with Geant4: validation of clinical molecular breast imaging system
    Lopez, Benjamin P.
    Guan, Fada
    Rauch, Gaiane M.
    Kappadath, S. Cheenu
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (12)
  • [38] Geant4 Based Monte Carlo Dose Calculation Engine for Radiation Therapy
    Xiao, Shanjie
    Yang, Xue
    Sztejnberg, Manuel
    Jevremovic, Tatjana
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (02) : 775 - 781
  • [39] GePEToS: A Geant4 Monte Carlo simulation package for positron emission tomography
    Jan, S
    Collot, J
    Gallin-Martel, ML
    Martin, P
    Mayet, F
    Tournefier, E
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 102 - 106
  • [40] Validation of Geant4 Simulation of Proton Energy Straggling: First Results
    Han, Min Cheol
    Pia, Maria Grazia
    Saracco, Paolo
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,