Stent-assisted coiling of intracranial aneurysms using LEO stents: long-term follow-up in 153 patients

被引:16
|
作者
Sedat, Jacques [1 ]
Chau, Yves [1 ]
Gaudart, Jean [2 ]
Sachet, Marina [1 ]
Beuil, Stephanie [3 ]
Lonjon, Michel [4 ]
机构
[1] Hop Pasteur 2, Unite Neurointervent, F-06000 Nice, France
[2] Aix Marseille Univ, INSERM, SESSTIM, IRD, Marseille, France
[3] Hop Pasteur 2, Unite Ultrasons, Nice, France
[4] Hop Pasteur 2, Unite Neurochirurg, Nice, France
关键词
Intracranial aneurysm; LEO stent; Endovascular treatment; Stent-assisted coiling; Clinical outcome; ACUTELY RUPTURED ANEURYSMS; SINGLE-CENTER EXPERIENCE; ENDOVASCULAR TREATMENT; NEUROFORM-STENT; ENTERPRISE STENT; CEREBRAL ANEURYSMS; EMBOLIZATION; COMPLICATIONS; PLACEMENT; STENOSIS;
D O I
10.1007/s00234-017-1965-1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Coiling associated with placement of a self-expandable intracranial stent has improved the treatment of intracranial wide-necked aneurysms. Little is known, however, about the durability of this treatment. The purpose of this report is to present our experience with the LEO stent and to evaluate the complications, effectiveness, and long-term results of this technique. We analyzed the records of 155 intracranial unruptured aneurysms that were treated by stent-assisted coiling with a LEO stent between 2008 and 2012. Procedural, early post-procedural, and delayed complications were recorded. Clinical and angiographic follow-up of patients was conducted over a period of at least 36 months. No procedural mortality was observed. One-month morbidity was observed in 14 out of 153 patients (9,15%). One hundred thirty-eight patients (with 140 aneurysms) had clinical and angiographic follow-up for more than 36 months. No aneurysm rupture was observed during follow-up. Four patients presented an intra-stent stenosis at 8 months, and 6 patients who had an early recurrence were retreated. Final results showed 85% complete occlusion, 13% neck remnants, and 2% stable incomplete occlusion. Stent-assisted coiling with the LEO stent is a safe and effective treatment for unruptured intracranial aneurysms. The long-term clinical outcomes with the LEO stent are excellent with a high rate of complete occlusion that is stable over time.
引用
收藏
页码:211 / 219
页数:9
相关论文
共 50 条
  • [31] Long-term outcomes of Low-profile Visualized Intraluminal Support device usage in stent-assisted coiling of intracranial aneurysm
    Yoo, Dong Hyun
    Cho, Young Dae
    Moon, Jusun
    Lee, Jeongjun
    Kang, Hyun-Seung
    Cho, Won-Sang
    Kim, Jeong Eun
    Hwang, Gyojun
    Kwon, O-Ki
    Han, Moon Hee
    JOURNAL OF CLINICAL NEUROSCIENCE, 2018, 50 : 287 - 291
  • [32] Stent-assisted coiling of intracranial aneurysms located on small vessels: midterm results with the LVIS Junior stent in 40 patients with 43 aneurysms
    Alghamdi, Faisal
    Mine, Benjamin
    Morais, Ricardo
    Scillia, Pietro
    Lubicz, Boris
    NEURORADIOLOGY, 2016, 58 (07) : 665 - 671
  • [33] Stent-Assisted Coiling of Intracranial Aneurysms Clinical and Angiographic Results in 216 Consecutive Aneurysms
    Piotin, Michel
    Blanc, Raphael
    Spelle, Laurent
    Mounayer, Charbel
    Piantino, Rhelen
    Schmidt, Paul J.
    Moret, Jacques
    STROKE, 2010, 41 (01) : 110 - 115
  • [34] Stent-Assisted Coiling in Acutely Ruptured intracranial Aneurysms: A Qualitative, Systematic Review of the Literature
    Bodily, K. D.
    Cloft, H. J.
    Lanzino, G.
    Fiorella, D. J.
    White, P. M.
    Kallmes, D. F.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (07) : 1232 - 1236
  • [35] Stent-assisted coil embolization of intracranial aneurysms using Solitaire stent
    Zhang, Jingbo
    Lv, Xianli
    Yang, Jun
    Wu, Zhongxue
    NEUROLOGY INDIA, 2012, 60 (03) : 278 - 282
  • [36] Propensity score-adjusted analysis on stent-assisted coiling versus coiling alone for ruptured intracranial aneurysms
    Goertz, Lukas
    Liebig, Thomas
    Pennig, Lenhard
    Timmer, Marco
    Styczen, Hanna
    Grunz, Jan-Peter
    Lichtenstein, Thorsten
    Schlamann, Marc
    Kabbasch, Christoph
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [37] Stent-Assisted Coiling in the Treatment of Unruptured Intracranial Aneurysms: A Randomized Clinical Trial
    Boisseau, W.
    Darsaut, T. E.
    Fahed, R.
    Drake, B.
    Lesiuk, H.
    Rempel, J. L.
    Gentric, J. -c.
    Ognard, J.
    Nico, L.
    Iancu, D.
    Roy, D.
    Weill, A.
    Chagnon, M.
    Zehr, J.
    Lavoie, P.
    Nguyen, T. N.
    Raymond, J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2023, 44 (04) : 381 - 389
  • [38] Long-term results of wide-necked intracranial bifurcation aneurysms treated with stent-assisted coiling using low-profile acandis acclino stents
    Melber, Katharina
    Boxberg, Frederik W.
    Schlunz-Hendann, Martin
    Brassel, Friedhelm
    Grieb, Dominik F. J.
    INTERVENTIONAL NEURORADIOLOGY, 2022, : 623 - 630
  • [39] Neuroform stent-assisted coiling of large and giant intracranial aneurysms: Angiographic and clinical outcomes in 71 consecutive patients
    Gao, Xu
    Liang, Guobiao
    Li, Youxiang
    Wu, Zhongxue
    NEUROLOGY INDIA, 2010, 58 (06) : 11 - 18
  • [40] Long-Term Follow-Up Study of Endovascularly Treated Intracranial Aneurysms
    Pyysalo, L. M.
    Keski-Nisula, L. H.
    Niskakangas, T. T.
    Kahara, V. J.
    Ohman, J. E.
    INTERVENTIONAL NEURORADIOLOGY, 2010, 16 (03): : 231 - 239